Sawo ARI3-90NB-P

SAWO ARIES ROUND ARI3 Electric Sauna Heater User Manual

Model: ARI3-90NB-P

1. Introducció

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your SAWO ARIES ROUND ARI3 Electric Sauna Heater. Please read this manual thoroughly before installation and use, and keep it for future reference.

Producte acabatview

The SAWO ARIES ROUND ARI3 is a high-quality electric sauna heater designed for both home and commercial use. Its vertical cylindrical shape ensures efficient heat distribution and steam generation. The heater features a durable stainless steel casing and an intuitive integrated control panel for ease of use.

SAWO ARIES ROUND ARI3 Electric Sauna Heater

Figure 1: SAWO ARIES ROUND ARI3 Electric Sauna Heater with sauna stones.

Informació de seguretat

Always follow local electrical codes and safety regulations. Installation should be performed by a qualified electrician.

2. Configuració i instal·lació

Desembalatge i inspecció

Carefully unpack the sauna heater and inspect it for any signs of damage during transit. Report any damage to your supplier immediately.

Stone Placement

The ARI3 model can hold up to 60 kg of sauna stones (diameter 5-10 cm). Arrange the stones loosely around the heating elements to allow for proper air circulation. Do not pack stones too tightly. The heating elements are separated from the stones by a special stone spacer to prolong their lifespan.

Close-up of sauna heater base and controls

Figura 2: Primer pla view of the heater's base and integrated controls.

Connexió elèctrica

The SAWO ARIES ROUND ARI3 is a multi-voltage heater, supporting either 230V single-phase (fuse: 1x40A) or 400V 3-phase (fuse: 3x16A) installation. Ensure the electrical supply matches the heater's requirements. The connection cable must be type HO7RN-F or equivalent and is not included.

Placement and Safety Distances

The heater is a floor-standing model. Maintain minimum safety distances from walls and ceiling.

Table 1: Minimum Safety Distances
MesuramentDistància
Distància mínima al sostre1200 mm
Minimum distance to side walls100 mm
SAWO ARIES ROUND ARI3 heater installed in a sauna

Figure 3: Heater installed in a sauna, demonstrating vertical placement.

3. Instruccions de funcionament

Panell de control integrat

The SAWO ARIES ROUND ARI3 features a convenient built-in control panel with an intuitive interface. The illuminated rotary knobs allow for easy adjustment even in low light conditions. The timer and thermostat controls can be switched sides for user convenience.

Sauna heater with wooden guard ring accessory

Figure 4: Heater with an optional wooden guard ring, highlighting the integrated controls at the base.

Configuració del temporitzador

The timer has an operating time of 1 to 4 hours and a preset time function of 1 to 8 hours.

  1. Turn the timer knob to select the desired operating duration.
  2. For a delayed start, use the preset time function to set when the heater should begin operation.

Ajust de la temperatura

The thermostat automatically maintains the selected temperature.

  1. Turn the thermostat knob to set your desired sauna temperature.
  2. The heater will cycle on and off to maintain this temperature.

Generating Steam

You can generate steam by pouring water onto the hot sauna stones, not only from the top but also from the sides due to the heater's efficient cylindrical design. Use only clean water.

4. Manteniment

Neteja

Ensure the heater is completely cool and disconnected from power before cleaning. Wipe the stainless steel casing amb anunciamp tela. No utilitzeu netejadors abrasius ni dissolvents.

Sauna Stone Replacement

Sauna stones should be inspected regularly and replaced when they start to crumble or lose their porous structure. This typically occurs every 1-2 years depending on usage. Replacing stones ensures efficient heating and proper steam generation.

Close-up of sauna stones in the heater

Figura 5: Primer pla view of the sauna stones within the heater's stainless steel grid.

5. Solució De Problemes

If you encounter issues with your SAWO ARIES ROUND ARI3 heater, refer to the following common problems and solutions. For more complex issues, contact a qualified service technician.

Taula 2: Guia de resolució de problemes
ProblemaCausa possibleSolució
Heater does not heat upNo power supply; tripped circuit breaker; faulty heating element; thermostat set too low.Check power connection and circuit breaker. Ensure thermostat is set correctly. If elements are faulty, contact service.
Sauna not reaching desired temperatureInsufficient heating time; sauna room too large for heater; poor insulation; stones packed too tightly.Allow more time for heating. Verify sauna room volume is within heater's capacity (8-13 m³). Rearrange stones for better airflow.
Excessive steam or water drippingToo much water poured on stones; stones are too old/crumbling.Pour less water. Replace old sauna stones.

6. Especificacions tècniques

Table 3: SAWO ARIES ROUND ARI3-90NB-P Specifications
CaracterísticaDetall
ModelARI3-90NB-P
Potència de sortida9.0 kW
Dimensions (H x A)930 mm x 300 mm
Pes14 kg
Tipus d'instal·lacióTerra de peu
Max. Stone Capacity60 kg (stones Ø 5-10 cm)
Recommended Sauna Room Size8-13 m³
Voltage Opcions230V 1-phase (1x40A fuse) or 400V 3-phase (3x16A fuse)
MaterialAcer inoxidable
Tauler de controlIntegrated, illuminated timer (1-4h operation, 1-8h preset) and thermostat

7. Garantia i Suport

Informació de la garantia

The SAWO ARIES ROUND ARI3 heater comes with a manufacturer's warranty:

Please retain your proof of purchase for warranty claims. The warranty does not cover sauna stones or silicone connection cables, as these are not included with the heater.

Atenció al client

For technical assistance, spare parts, or warranty inquiries, please contact your local SAWO distributor or the point of purchase.

Fabricant: Sawo
Número de model: ARI3-90NB-P

Documents relacionats - ARI3-90NB-P

Preview Manual del controlador de potència Saunova 2.0 - SAWO
Manual d'usuari complet per al controlador de potència SAWO Saunova 2.0, que detalla la instal·lació, el funcionament, les precaucions de seguretat i les especificacions tècniques dels sistemes de calefacció de sauna.
Preview Diagrames d'instal·lació i distàncies de seguretat de l'escalfador SAWO Cirrus
Diagrames d'instal·lació complets i especificacions de distància mínima de seguretat per als escalfadors SAWO Cirrus, que cobreixen tant els models de control separats com els integrats. Guia essencial per a una instal·lació correcta.
Preview SAWO Glass Front Sauna Room Assembly Manual
This official assembly manual from SAWO guides users through the complete installation process for their Glass Front Sauna Rooms. It features detailed parts lists, step-by-step assembly instructions, electrical layout diagrams, and essential maintenance tips for models like the 1414LS/RS and 2020ML.
Preview SAWO Tower Heater Round User Manual
This user manual provides detailed instructions for the installation, operation, and maintenance of the SAWO Tower Heater Round. It covers safety precautions, technical specifications, troubleshooting, and spare parts.
Preview SAWO Infrared 2.0 Control Unit Manual: Installation and Operation Guide
Comprehensive user manual for the SAWO Infrared 2.0 Control Unit. Includes detailed instructions on installation, operation, safety guidelines, and troubleshooting for infrared sauna rooms.
Preview SAWO Nordex Mini Heater Käyttöohjeet ja Käyttöopas
Tutustu SAWO Nordex Mini -saunakiukaan yksityiskohtaisiin käyttöohjeisiin. Tämä opas kattaa asennuksen, turvallisuusohjeet, käytön, huollon ja vianetsinnän suomeksi ja englanniksi.