1. Introducció
The Lascar Electronics EL-21CFR-TP-LCD EasyLog 21CFR FDA-Compatible Temperature Data Logger with Probe is a standalone device designed for accurate temperature monitoring. This data logger is compliant with 21CFR regulations and is capable of recording and displaying over 32,000 temperature readings from its high-accuracy thermistor probe. It features an integrated LCD screen and a push-button interface, allowing users to easily view the most recent, highest, and lowest recorded temperature values.
2. Informació de seguretat
Please read all instructions carefully before operating the device. Failure to do so may result in inaccurate readings or damage to the unit.
- Do not expose the data logger to extreme temperatures outside its specified operating range (-35 to +80°C / -31 to +176°F).
- Avoid exposing the device to excessive moisture or corrosive substances.
- Handle the thermistor probe with care to prevent damage.
- Ensure proper ventilation if used in an enclosed space.
- No intenteu desmuntar ni modificar el dispositiu. Encarregueu tot el manteniment a personal qualificat.
- Elimineu el dispositiu i els seus components d'acord amb la normativa ambiental local.
3. Producte acabatview
The EL-21CFR-TP-LCD data logger is a compact and robust device designed for reliable temperature monitoring.

Figure 1: Lascar Electronics EL-21CFR-TP-LCD Data Logger. The image shows the black data logger unit with an LCD display showing "12.0°C", a button, and a USB connector at one end. A clear protective cap is shown detached from the USB end.
Components clau:
- Pantalla LCD: Shows current temperature, highest, lowest, and other status indicators.
- Polsador: Used to cycle through display modes and initiate logging (if configured).
- Connector USB: For connecting to a computer to configure the logger and download data.
- Thermistor Probe Input: Port for connecting the external thermistor probe.
- Tapa protectora: Covers the USB connector when not in use.
4. Configuració
4.1 Instal·lació del programari
Before using the data logger, you must install the EasyLog 21CFR software on your computer. This software is required for configuring the logger, downloading data, and viewgràfics.
- Obtain the EasyLog 21CFR software from the manufacturer's official weblloc o el suport d'instal·lació proporcionat.
- Seguiu les instruccions a la pantalla per completar la instal·lació del programari.
- Assegureu-vos que l'ordinador compleix els requisits mínims del sistema per al programari.
4.2 Configuració inicial
Once the software is installed, connect the data logger to your computer via the USB port.
- Remove the protective cap from the USB connector of the data logger.
- Plug the data logger into an available USB port on your computer.
- Launch the EasyLog 21CFR software. The software should detect the connected data logger.
- Within the software, configure the desired logging parameters, including:
- Logging rate (e.g., every 10 minutes, every hour)
- Start mode (e.g., immediate, delayed start, push-button start)
- Llindars d'alarma (límits de temperatura alts i baixos)
- Units of measurement (°C or °F)
- Apply the settings to the data logger. The logger is now ready for deployment.
4.3 Connexió de la sonda
Connect the thermistor probe to the designated input port on the data logger. Ensure a secure connection for accurate readings.
5. Funcionament
5.1 Inici del registre de dades
The method for starting data logging depends on the configuration set in the software:
- Inici immediat: Logging begins as soon as the settings are applied from the software.
- Inici retardat: Logging begins after a pre-set time delay.
- Botó d'inici: Press and hold the push-button on the data logger for approximately 3 seconds until the 'REC' indicator appears on the LCD.
5.2 Viewing Readings on LCD
Press the push-button briefly to cycle through the displayed information on the LCD:
- Temperatura actual: The real-time temperature reading from the probe.
- Highest Recorded Temperature: The maximum temperature recorded during the current logging session.
- Lowest Recorded Temperature: The minimum temperature recorded during the current logging session.
- Logging Status: Indicators such as 'REC' (recording), 'STOP' (stopped), 'FULL' (memory full).
5.3 Aturar el registre de dades
Logging can be stopped in several ways, depending on the configuration:
- Memory Full: Logging automatically stops when the device's memory capacity (32,000 readings) is reached.
- Push-Button Stop: If configured, press and hold the push-button for approximately 3 seconds until the 'STOP' indicator appears.
- Via Software: Connect the logger to a computer and use the EasyLog 21CFR software to stop the logging session.
5.4 Descàrrega de dades
To retrieve recorded data:
- Connect the data logger to your computer via USB.
- Open the EasyLog 21CFR software.
- El programari detectarà automàticament el registrator i us demanarà que descarregueu les dades.
- Follow the software instructions to save the data, which can then be viewed, analyzed, and exported in various formats.
6. Manteniment
6.1 Neteja
Netegeu l'exterior del registrador de dades amb un drap suau iamp cloth. Do not use abrasive cleaners or solvents. Ensure the USB port and probe input are free from dust and debris.
6.2 Substitució de la bateria
The data logger contains an internal battery. If the battery indicator on the LCD or software shows low power, the battery may need replacement. Refer to the EasyLog 21CFR software documentation or contact customer support for battery replacement procedures, as this may require specialized tools or service.
6.3 Calibració
For applications requiring high accuracy and compliance, periodic calibration of the data logger and its probe is recommended. Consult the manufacturer's guidelines or a certified calibration service for details.
7. Solució De Problemes
| Problema | Causa possible | Solució |
|---|---|---|
| Device not detected by software. | USB connection issue, software not running, driver issue. | Ensure USB cable is securely connected. Restart software and computer. Reinstall USB drivers if necessary. Try a different USB port. |
| La pantalla LCD està en blanc o tènue. | Low battery, device not active. | Connect to USB to check if it powers on. If persistent, battery may need replacement. |
| Lectures de temperatura inexactes. | Probe not properly connected, probe damage, environmental interference, calibration needed. | Check probe connection. Inspect probe for visible damage. Ensure probe is placed in a representative environment. Consider recalibration. |
| Data logging not starting. | Incorrect start mode configuration, memory full. | Verify start mode settings in software. Check if memory is full; download data and reconfigure. |
8. Especificacions
| Característica | Detall |
|---|---|
| Número de model | EL-21CFR-TP-LCD+ |
| Interval de mesura | -35 a +80 °C / -31 a +176 °F |
| Capacitat de memòria | 32,000 lectures de temperatura |
| Tipus de sonda | Thermistor probe |
| Mostra | LCD with current, highest, and lowest readings |
| Interfície | USB |
| Compliment | 21 CFR |
| Pes de l'article | 1 lliures |
| Fabricant | COLE-PARMER |
| Primera data disponible | 20 de juny de 2017 |
9. Garantia i Suport
Specific warranty information for the Lascar Electronics EL-21CFR-TP-LCD data logger is typically provided with the product packaging or available on the manufacturer's official website. Please refer to these resources for detailed terms and conditions regarding warranty coverage.
Atenció al client:
For technical assistance, troubleshooting beyond this manual, or inquiries regarding service and calibration, please contact Lascar Electronics customer support. Contact details can usually be found on their official weblloc o a la documentació del producte.