1. Producte acabatview
The ABB Adam DYN-Info M12-5 Safety Sensor Unit is designed for safety applications, providing reliable DYNlink signals and information output. This unit is built to withstand harsh environments, featuring an IP69K rating. It includes an M12-5 male connector for easy integration.
Les característiques clau inclouen:
- Easier troubleshooting capabilities.
- Suitable for operation in harsh environments.
- Local reset function for operational convenience.
- Achieves Performance Level 'e' (PL e) with fewer components.
- Offers large mounting tolerance for flexible installation.

Figura 1: Frontal view of the ABB Adam DYN-Info M12-5 Safety Sensor Unit, highlighting its robust yellow casing and M12-5 connector.
2. Informació de seguretat
Important: Read all instructions carefully before installation, operation, or maintenance. Failure to follow these instructions may result in serious injury or equipment damage.
- Ensure all power is disconnected before performing any installation or maintenance procedures.
- La instal·lació i el cablejat han de ser realitzats per personal qualificat d'acord amb totes les normes elèctriques locals i nacionals.
- Do not modify the sensor unit. Any modifications may compromise safety and void the warranty.
- Verify proper functioning of the safety system after installation and before putting the machinery into operation.
- The unit operates at 220 Volts. Take appropriate precautions when handling electrical connections.
3. Configuració i instal·lació
The Adam DYN-Info M12-5 Safety Sensor Unit is designed for wall mounting. Proper installation is crucial for optimal performance and safety.
3.1 Muntatge
- Select a suitable wall-mounting location that provides clear access and optimal detection range for the application.
- Use the provided DA 1B distance plates and DA 2B distance rings as needed to achieve the correct mounting distance and alignment. Four pieces of each are included.
- Securely fasten the sensor unit to the wall using appropriate hardware (not included, unless specified).

Figure 2: Dimensional drawing of the sensor unit, with measurements in millimeters. This diagram aids in precise mounting and space planning.
3.2 Connexió elèctrica
- Connect the M12-5 male connector to the corresponding female connector of your safety system.
- Ensure all connections are tight and secure to prevent intermittent operation or electrical hazards.
- Verify that the power supply matches the sensor's requirements (24 VDC, 30 mA, 220 Volts as specified).
3.3 Detection Distance
The sensor unit has specific detection distance parameters that must be considered during installation to ensure reliable operation.

Figura 3: lateral view diagram illustrating the detection distance range of the sensor, indicating optimal positioning for the safety application.

Figura 4: Frontal view diagram detailing the detection distance and alignment tolerances for the sensor unit.
4. Instruccions de funcionament
Once installed and powered, the Adam DYN-Info M12-5 Safety Sensor Unit continuously monitors the safety area. It provides DYNlink signals and additional information output to the connected safety control system.
- DYNlink Signal: This signal communicates the safety status to the connected safety relay or PLC.
- Information Output: Provides diagnostic data or operational status to the control system, aiding in system monitoring and troubleshooting.
- Local Reset Function: If the sensor triggers a safety stop, a local reset may be performed according to the safety system's configuration. Refer to your system's documentation for specific reset procedures.
5. Manteniment
The ABB Adam DYN-Info M12-5 Safety Sensor Unit is designed for minimal maintenance. Regular checks ensure continued reliable operation.
- Neteja: Periodically clean the sensor surface with a soft, damp cloth. Avoid abrasive cleaners or solvents that could damage the housing or sensing elements.
- Inspecció: Regularly inspect the sensor unit and its connections for any signs of physical damage, wear, or corrosion. Ensure all cables are securely connected.
- Prova funcional: Perform routine functional tests as required by your safety system's maintenance schedule to confirm the sensor's proper operation.
6. Solució De Problemes
This section provides guidance for common issues. For complex problems, contact ABB technical support.
| Problema | Causa possible | Solució |
|---|---|---|
| El sensor no respon | No power, incorrect wiring, sensor misalignment, damaged unit. | Check power supply. Verify wiring connections. Adjust sensor alignment. Inspect for damage; replace if necessary. |
| Funcionament intermitent | Loose connections, environmental interference, minor misalignment. | Tighten all connections. Check for sources of interference. Re-align sensor carefully. |
| Falsos desencadenants | Obstruction in detection zone, excessive vibration, incorrect sensitivity setting (if applicable). | Clear detection path. Secure mounting to reduce vibration. Consult system documentation for sensitivity adjustments. |
7. Especificacions
| Atribut | Valor |
|---|---|
| Marca | FIG |
| Número de model | 2TLA020051R5100 |
| Descripció | Adam safety sensor unit with DYNlink signal and information output. |
| Tipus de connector | M12-5 Male Connector |
| Classificació de protecció d'entrada (IP). | IP69K |
| Color | Yellow (Unit), Black (Connector) |
| Font d'alimentació | Elèctric amb cable |
| Voltage | 220 Volts (Operating) / 24 VDC (Control) |
| Actual | 30 mA |
| Pes de l'article | 0.03 quilograms (aproximadament 0.915 unces) |
| Tipus de muntatge | Muntatge de paret |
| Material | Acetat de vinil etilè (EVA) |
| Temperatura de funcionament | Fins a 85 graus centígrads |
| Components inclosos | Sensor, 4pcs DA 1B distance plates, 4pcs DA 2B distance rings |
8. Garantia i Suport
For warranty information, please refer to the official ABB product documentation or contact ABB customer service directly. ABB provides technical support for its products to ensure optimal performance and safety.
For technical assistance, troubleshooting beyond this manual, or spare parts inquiries, please visit the official ABB weblloc web o poseu-vos en contacte amb el vostre representant local d'ABB.
Oficial d'ABB Weblloc: www.abb.com