Lincat 4251391256989

Lincat Quartz Heater Instruction Manual

Model: 4251391256989

1. Producte acabatview

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Lincat Quartz Heater. This heater is designed for use in LSC and LPC Salamandre infrared warmers.

Key specifications include a power output of 500W, operating voltage of 240V, a length of 460mm, and an electrical diameter of 9mm.

2. Informació de seguretat

Llegiu atentament totes les instruccions de seguretat abans de la instal·lació i l'ús. Si no seguiu aquestes instruccions, podeu patir descàrregues elèctriques, incendis o lesions greus.

  • Seguretat elèctrica: Ensure the power supply is disconnected before installation, maintenance, or replacement. This product operates at 240V; improper handling can be dangerous.
  • Risc de calor: The quartz heater generates high temperatures during operation. Avoid direct contact with the element when powered. Allow sufficient cooling time before handling.
  • Instal·lació: Installation should only be performed by a qualified technician in accordance with local electrical codes and regulations.
  • Compatibilitat: Use only with Lincat LSC and LPC Salamandre infrared warmers as specified. Do not attempt to use this heater in incompatible appliances.
  • Inspecció de danys: Before installation, inspect the heater for any signs of damage. Do not install a damaged heater.

3. Components i dimensions del producte

The Lincat Quartz Heater is a tubular heating element designed for efficient heat generation in professional catering equipment.

Lincat Quartz Heater element, a long, slender heating tube with electrical connections at both ends.

Figure 3.1: Lincat Quartz Heater element. This image shows the full length of the quartz heating tube, which is typically used in commercial infrared warmers.

Technical diagram of the Lincat Quartz Heater showing length 'L' and diameter 'Ø' measurements.

Figure 3.2: Technical diagram illustrating the dimensions of the quartz heater. 'L' denotes the overall length of 460mm, and 'Ø' indicates the electrical diameter of 9mm.

lateral view of the Lincat Quartz Heater element, highlighting its cylindrical shape and end connections.

Figura 3.3: lateral view of the Lincat Quartz Heater. This perspective emphasizes the uniform cylindrical structure and the connection points at each end of the heating element.

4. Configuració i instal·lació

Important: Installation must be performed by a qualified electrician. Ensure the appliance is disconnected from the main power supply before proceeding.

  1. Desconnexió d'alimentació: Turn off and unplug the Lincat Salamandre infrared warmer from the electrical outlet.
  2. Tauler d'accés: Locate and carefully open the access panel on the Salamandre warmer that houses the heating elements. Refer to the Salamandre warmer's specific manual for panel removal instructions.
  3. Remove Old Heater (if applicable): If replacing an existing heater, carefully disconnect the electrical terminals and unclip or slide out the old quartz heater. Dispose of the old heater responsibly.
  4. Instal·lar un escalfador nou: Gently insert the new Lincat Quartz Heater into its designated slots or clips. Ensure it is securely seated.
  5. Connecteu el cablejat: Reconnect the electrical terminals to the new heater. Ensure connections are tight and correct according to the Salamandre warmer's wiring diagram.
  6. Panell segur: Tanqueu i assegureu el panell d'accés.
  7. Prova: Reconnect the Salamandre warmer to the power supply and perform a functional test to ensure the new heater operates correctly.

5. Instruccions de funcionament

This quartz heater is an internal component of Lincat LSC and LPC Salamandre infrared warmers. Its operation is controlled by the warmer's main controls.

  • Ensure the heater is correctly installed within the Salamandre warmer.
  • Operate the Salamandre warmer according to its specific user manual. The quartz heater will activate as part of the warmer's heating cycle.
  • Do not attempt to operate the quartz heater independently outside of its intended appliance.

6. Manteniment i cura

Regular maintenance ensures optimal performance and extends the lifespan of the heater. Always disconnect power before any maintenance.

  • Neteja: Allow the heater to cool completely. Gently wipe the exterior of the quartz tube with a dry, soft cloth to remove any dust or debris. Do not use abrasive cleaners or liquids directly on the heating element.
  • Inspecció: Periodically inspect the heater for any signs of wear, cracks, or discoloration. Check electrical connections for tightness.
  • Substitució: If the heater shows signs of damage or reduced performance, it should be replaced by a qualified technician.

7. Solució De Problemes

If you experience issues with your Lincat Quartz Heater, consider the following common troubleshooting steps. For complex issues, contact a qualified technician.

ProblemaCausa possibleSolució
Heater not glowing/heatingNo power to the appliance; faulty wiring connection; heater element failure.Check power supply to the Salamandre warmer. Verify wiring connections. If power is present and connections are good, the heater may need replacement.
Calefacció desigualPartial element failure; debris on element.Inspect the element for visible damage. Clean the element if necessary (ensure power is off and element is cool). If damage is present, replace the heater.
Flickering or intermittent operationLoose electrical connection; internal fault.Check and tighten all electrical connections. If the problem persists, professional inspection and replacement are recommended.

8. Especificacions

  • Marca: Lincat
  • Número de model: 4251391256989
  • ASIN: B073Z8TQTG
  • Aplicació: Salamandre Infrared Warmer (LSC, LPC series)
  • Potència: 500 W
  • Voltage: 240 V
  • Longitud: 460 mm
  • Electrical Diameter: 9 mm
  • Fabricant: Lincat

9. Garantia i Suport

For warranty information, please refer to the documentation provided with your Lincat Salamandre infrared warmer or contact Lincat customer support directly. This quartz heater is a replacement part, and its warranty may be subject to the terms of the original appliance or specific replacement part warranty.

For technical support or inquiries regarding this product, please contact your authorized Lincat dealer or Lincat customer service.

Documents relacionats - 4251391256989

Preview Forn Lincat CiBO+: Instruccions d'instal·lació i funcionament
Instruccions completes d'instal·lació i funcionament per al forn d'alta velocitat Lincat CiBO+ UL. Inclou directrius de seguretat, dades tècniques i procediments operatius.
Preview Marquesines d'extracció Lincat SmartVent: Instruccions d'ús i instal·lació
Guia d'usuari i instal·lació per a les marquesines d'extracció Lincat SmartVent (SV1212, SV1216, SV1220, SV1224). Cobreix les especificacions tècniques, els procediments d'instal·lació, el funcionament, la neteja, la substitució de components i la informació sobre la garantia.
Preview Instruccions d'instal·lació, funcionament i manteniment de la caldera i el refrigerador d'aigua Lincat EB3FX/HC/PB
Guia completa per a la caldera i el refrigerador d'aigua Lincat EB3FX/HC/PB, que cobreix la instal·lació, el funcionament, el manteniment, la resolució de problemes i les precaucions de seguretat. Inclou dades tècniques i una llista de peces de recanvi.
Preview Lincat Waterboiler EB3FX, EB4FX, EB6FX, EB6TFX, EB3FX/PB, EB3FX/TT Installation, Operating and Servicing Instructions
Comprehensive installation, operating, and servicing instructions for Lincat Waterboiler models EB3FX, EB4FX, EB6FX, EB6TFX, EB3FX/PB, and EB3FX/TT. Includes technical data, safety precautions, maintenance, and troubleshooting.
Preview Unitats elèctriques de filtració de fums Lincat L3, L4: instruccions d'instal·lació, funcionament i manteniment
Guia completa per a les unitats elèctriques de filtració de fums Lincat L3 i L4, que cobreix la instal·lació, el funcionament, el manteniment, la resolució de problemes i les peces de recanvi. Inclou avisos de seguretat i especificacions tècniques.
Preview Marquesines d'extracció Lincat SmartVent: Manual d'usuari i instal·lació
Guia completa d'usuari i instal·lació per a les marquesines d'extracció Lincat SmartVent, que cobreix els models SV1212, SV1216, SV1220 i SV1224. Inclou dades tècniques, avisos de seguretat, procediments d'instal·lació, connexions elèctriques, posada en marxa, neteja, substitució de components i informació sobre la garantia per a sistemes de ventilació de cuines comercials.