Paradox PCS250

Manual d'usuari del mòdul de comunicació GSM/GPRS Paradox PCS250

Model: PCS250 | Brand: Paradox

1. Introducció

The Paradox PCS250 is a GSM/GPRS communication module designed to enhance the connectivity of Paradox alarm systems. It enables communication via the GSM/GPRS network, providing advanced features such as remote system management, voice alerts, and SMS notifications. This manual provides detailed instructions for the installation, operation, and maintenance of your PCS250 module.

2. Informació de seguretat

Please read all safety instructions carefully before installing and operating the PCS250 module. Failure to follow these instructions may result in damage to the device, property, or personal injury.

3. Producte acabatview

The Paradox PCS250 is a compact and elegant communication module designed to integrate seamlessly with compatible Paradox alarm control panels.

3.1 Característiques clau

3.2 Contingut del paquet

3.3 Diagrama del producte

Paradox PCS250 GSM/GPRS Communication Module front view

Figura 1: Davant view of the Paradox PCS250 module. The left side features a series of LED indicators for status and signal strength, while the right side is a smooth, white panel. The bottom edge shows the Paradox logo and a mounting screw hole.

4. Configuració i instal·lació

The PCS250 module requires careful installation to ensure optimal performance. It is recommended that installation be performed by a qualified professional.

4.1 Comprovació de compatibilitat

Ensure your Paradox control panel is compatible with the PCS250 module:

4.2 Inserció de la targeta SIM

  1. Power off the control panel and the PCS250 module before inserting the SIM card.
  2. Locate the SIM card slot(s) on the PCS250 module. There are two possible slots.
  3. Carefully insert the activated SIM card into one of the slots. Ensure it is fully seated.
  4. Nota: SIM card slots can be fragile. Handle with extreme care.

4.3 Cablejat i connexió

  1. Connect the PCS250 module directly to the control panel using the provided wiring. Refer to the control panel's manual for specific connection points.
  2. If installing the module up to 300m from the control panel, use the optional CVT485 module.
  3. Connect the external supplementary power supply to the PCS250 module as recommended.
  4. Securely mount the PCS250 module in a location with good GSM signal reception.

5. Instruccions de funcionament

Once installed and powered, the PCS250 module will begin communicating with your Paradox control panel and the GSM/GPRS network.

5.1 Indicadors d'estat

The LEDs on the module indicate its operational status and GSM/GPRS signal strength. Refer to the specific LED guide in the full technical manual for detailed interpretations.

5.2 SMS Notifications and Control

5.3 Voice Communication (with VDMP3)

5.4 Remote Management via GPRS

The PCS250 allows remote management of your control panel using Paradox software via the GPRS network:

Refer to the respective software manuals for detailed instructions on remote management.

6. Manteniment

Regular maintenance ensures the longevity and optimal performance of your PCS250 module.

6.1 actualitzacions de microprogramari

The firmware of both the control panel and the PCS250 module can be updated remotely via the GPRS network. Consult your installer or Paradox technical support for information on available updates and the update procedure.

6.2 SIM Card Management

6.3 Neteja

Clean the exterior of the module with a soft, dry cloth. Do not use abrasive cleaners or solvents.

7. Solució De Problemes

This section addresses common issues you might encounter with the PCS250 module.

ProblemaCausa possibleSolució
No GSM Signal / Weak SignalPoor module placement; SIM card not activated; network issues.Relocate the module to an area with better signal. Consider an external antenna extension. Verify SIM card activation with your mobile operator.
SMS/Voice Alerts Not ReceivedIncorrect phone numbers programmed; insufficient SIM credit; SIM card issues; VDMP3 module not connected/faulty.Check programmed phone numbers in the control panel. Verify SIM card credit and expiry. Ensure VDMP3 module is correctly installed and functional.
Remote Management (GPRS) FailsGPRS service not enabled on SIM; incorrect software configuration; network issues.Confirm GPRS service is active on your SIM card. Check software (WinLoad, NEware, BabyWare) settings. Ensure stable internet connection on both ends.
El mòdul no responNo power; loose connection; module fault.Check power supply and all connections. Power cycle the module and control panel. If problem persists, contact technical support.

8. Especificacions

CaracterísticaDetall
Número de modelPCS250
MarcaParadoxa
FabricantPARADOXA
Dimensions (L x A x A)19.05 x 10.41 x 6.1 cm (7.5 x 4.1 x 2.4 polzades)
Pes280 grams (0.62 lliures)
ColorBlanc
Font d'alimentacióBattery with external power supply
Mètode d'instal·lacióProfessional hard-wired
Tecnologia de connectivitatWired (to control panel)
Dispositius compatiblesMAGELLAN MG5000/MG5050 (v4.0+), Spectra SP (v3.42+), DIGIPLEX EVO (v2.02+) alarm control panels
Components inclososGSM/GPRS Communication Module, VDMP3 Voice Communication Module
Ús recomanatEnhance alarm system communication and enable remote management

9. Garantia i Suport

Specific warranty information for the Paradox PCS250 module is typically provided at the point of purchase or within the product packaging. Please refer to your purchase documentation or contact your authorized Paradox dealer for details regarding warranty coverage and terms.

For technical support, troubleshooting assistance beyond this manual, or service inquiries, please contact your professional installer or Paradox customer support directly. Contact information can usually be found on the Paradox official weblloc web o a l'embalatge del producte.

Documents relacionats - PCS250

Preview Paradox PCS250 GPRS/GSM Communicator Module: Reference and Installation Manual
This comprehensive manual details the installation, configuration, and operation of the Paradox PCS250 GPRS/GSM Communicator Module. Learn about its features, connectivity options, SMS reporting capabilities, and compatibility with Paradox security systems.
Preview Paradox PCS265V8 LTE Communicator Module Installation Manual
This installation manual provides detailed instructions for connecting, programming, and operating the Paradox PCS265V8 LTE Communicator Module. It covers system integration, SIM card setup, LED functionality, reporting options, technical specifications, and certifications.
Preview Paradox PCS265V7 LTE Communicator Module Installation and Programming Guide
Comprehensive guide for installing and programming the Paradox PCS265V7 LTE Communicator Module, covering connections, setup, LED indicators, network configuration, SMS commands, technical specifications, and certifications.
Preview Paradox SP5500+/SP6000+ User Guide: Expandable Security Systems
Comprehensive user guide for Paradox SP5500+ and SP6000+ expandable security systems. Learn about installation, operation, features like StayD, arming/disarming, remote controls, and communication options.
Preview Manual d'instal·lació del mòdul d'expansió d'entrada de 8 zones Paradox ZX82
Aquest manual d'instal·lació proporciona detalls complets per al mòdul d'expansió d'entrada de 8 zones Paradox ZX82, que cobreix les seves característiques, la compatibilitat amb els panells de control Paradox, els procediments de connexió, les instruccions de programació per als sistemes EVO i MG/SP, les funcions dels indicadors LED, les especificacions tècniques i la informació d'actualització del firmware.
Preview Guia de l'usuari de Paradox Magellan i Spectra SP
Guia d'usuari completa per als sistemes d'alarma Paradox Magellan i Spectra SP, que cobreix la configuració, el funcionament, funcions com StayD, comandaments a distància, opcions de comunicació i resolució de problemes.