Brecknell LPS150

Brecknell LPS150 Portable Shipping Scale User Manual

Model: LPS150 | Brand: Brecknell

1. Introducció

This manual provides essential instructions for the proper setup, operation, and maintenance of your Brecknell LPS150 Portable Shipping Scale. Please read this manual thoroughly before using the scale to ensure safe and efficient operation. The LPS150 is designed for shipping, warehouse, and general-purpose weighing applications, offering portability and ease of use.

2. Informació de seguretat

  • No sobrecarregueu la bàscula més enllà de la seva capacitat màxima de 68 kg (150 lliures).
  • Avoid dropping the scale or subjecting it to severe shocks.
  • Do not immerse the scale or its components in water or other liquids.
  • Use only the provided AC adapter or specified batteries.
  • Mantingueu la bàscula allunyada de camps electromagnètics forts.
  • Ensure the scale is placed on a stable, level surface during operation.

3. Què hi ha a la caixa

Desembaleu amb cura tots els components i verifiqueu que heu rebut els articles següents:

  • Weighing Platform with Indicator and Bracket
  • Adaptador de corrent alterna
  • 4 x piles AAA
  • Cable RS-232
  • Manual d'usuari (aquest document)
Contents of the Brecknell LPS150 scale box, including platform, indicator, power adapter, batteries, and cables.

Image 3.1: All components included with the Brecknell LPS150 Portable Shipping Scale.

4. Producte acabatview

4.1 Components

The Brecknell LPS150 scale consists of a stainless steel weighing platform and a remote LCD indicator connected by a coiled cable. The indicator features a digital display and control buttons.

Diagram showing the Brecknell LPS150 scale with labels for the stainless steel weighing platform, 0.625 inch high LCD display, and operator keys.

Image 4.1: Labeled diagram of the LPS150 scale components.

4.2 Pantalla i controls

The indicator features a 0.63-inch, 5-digit LCD display. The operator keys include:

  • ON / OFF / ZERO: Powers the scale on or off, and zeros the display.
  • UNITATS: Changes the weighing unit (lb, kg, lb/oz).
  • TARA: Subtracts the weight of a container.
  • HOLD / PRINT: Holds the displayed weight or sends data via RS-232.

5. Configuració

5.1 Col·locació

Place the weighing platform on a firm, level, and stable surface. Ensure there are no obstructions around the platform that could interfere with accurate weighing. The indicator can be placed on a desk or mounted to a wall using the included bracket.

Brecknell LPS150 scale in a warehouse setting, with the platform on the floor and the indicator mounted on a wall next to a computer workstation.

Imatge 5.1: Ex.ample of scale placement with wall-mounted indicator.

5.2 Connexió d'alimentació

The LPS150 scale can be powered by either the included AC adapter or four AAA batteries.

  • Adaptador de CA: Connect the AC adapter to the power input port on the indicator and plug it into a standard electrical outlet.
  • Bateries: Open the battery compartment on the back of the indicator and insert four AAA batteries, observing correct polarity.

5.3 Connecting the Indicator to the Platform

Connect the coiled cable from the weighing platform to the corresponding port on the indicator. Ensure the connection is secure.

6. Instruccions de funcionament

6.1 Pesatge bàsic

  1. Premeu el botó ON / OFF / ZERO button to power on the scale. The display will show "0.00" when ready.
  2. Place the item to be weighed gently on the center of the weighing platform.
  3. Read the weight displayed on the LCD.
  4. Remove the item from the platform. The display should return to zero. If not, press ON / OFF / ZERO to re-zero.
Brecknell LPS150 scale showing a package on the platform and the digital display reading 0.00.

Image 6.1: The LPS150 scale ready for weighing.

Brecknell LPS150 scale with a white box on the platform, displaying a weight of 3.30 lbs.

Image 6.2: Weighing a package on the LPS150 scale.

6.2 Conversió d'unitats

To change the weighing unit:

  • With the scale on and displaying weight, press the UNITATS botó.
  • The display will cycle through available units: pounds (lb), kilograms (kg), and pounds/ounces (lb/oz).
  • Release the button when the desired unit is shown.

6.3 Funció de tara

The Tare function allows you to subtract the weight of a container, so only the net weight of the contents is displayed.

  1. Col·loqueu un recipient buit a la plataforma de pesatge.
  2. Espereu que el pes s'estabilitzi.
  3. Premeu el botó TARA button. The display will return to "0.00" and the TARE indicator will illuminate.
  4. Add items to the container. The display will show only the weight of the added items.
  5. To clear the tare, remove the container from the platform and press the TARA botó de nou.

6.4 Funció Hold

The Hold function allows you to temporarily freeze the displayed weight, which is useful for weighing large or awkwardly shaped items that might obscure the display.

  • Col·loqueu l'article a la plataforma.
  • Once the weight is stable, press the HOLD / PRINT button. The displayed weight will be held, and the HOLD indicator will illuminate.
  • To release the held weight, press the HOLD / PRINT botó de nou.

6.5 RS-232 Communication Setup (for UPS Worldship)

The LPS150 scale includes an RS-232 port for data communication with compatible software, such as UPS Worldship. Correct configuration of both the scale and your computer's serial port is crucial for proper functionality.

6.5.1 Configuració d'escala

  1. Ensure the scale is powered off.
  2. Manteniu premut el botó ON / OFF / ZERO botó i el UNITATS button simultaneously until the display shows "P1". This enters the setup menu.
  3. Premeu el botó TARA button repeatedly to cycle through the programming parameters (P1, P2, P3, etc.) until you reach P4.
  4. At P4, press the UNITATS button to change the setting to 7 (NCI protocol).
  5. Premeu el botó TARA button to save the P4 setting and advance to P5.
  6. At P5, press the UNITATS button to change the setting to 2 (4800 baud rate).
  7. Premeu el botó TARA button to save the P5 setting and advance to P6.
  8. At P6, press the UNITATS button to change the setting to 2 (7E1 data format).
  9. Premeu el botó ON / OFF / ZERO button to save all settings and exit the setup menu.

6.5.2 Computer Serial Port Configuration (Windows PC)

  1. Connect the RS-232 cable from the scale indicator to an available serial port on your computer. If your computer does not have a serial port, a USB-to-serial adapter may be required.
  2. Open Device Manager (search for "Device Manager" in the Windows search bar).
  3. Expand the "Ports (COM & LPT)" section.
  4. Identify the COM port assigned to your scale (e.g., COM1, COM3). Double-click on it to open its Properties.
  5. Go to the "Port Settings" tab and configure as follows:
    • Bits per segon: 4800
    • Bits de dades: 7
    • Paritat: Fins i tot
    • Stop Bits: 1
    • Control de flux: Cap
  6. Click "OK" to save the settings and close Device Manager.

6.5.3 UPS Worldship Configuration

  1. Open UPS Worldship software.
  2. Navigate to the "Tools" tab.
  3. Select "System Preferences" and then click on "Hardware".
  4. Under the Scale settings, change the "Scale port" to the COM port you identified in Device Manager (e.g., COM1).
  5. Change the "Scale Type" to "NCI 3835".
  6. Click "Test Scale" to verify communication. The weight from the scale should now be reported in Worldship.

7. Manteniment

7.1 Neteja

To maintain accuracy and prolong the life of your scale:

  • Wipe the platform and indicator with a soft, damp tela.
  • No utilitzeu netejadors abrasius, dissolvents ni productes químics agressius.
  • Ensure no liquids enter the indicator or the gaps around the platform.

7.2 Substitució de la bateria

If the scale is powered by batteries and the display becomes dim or erratic, it's time to replace the batteries. Open the battery compartment on the back of the indicator, remove the old batteries, and insert four new AAA batteries, ensuring correct polarity.

8. Solució De Problemes

ProblemaCausa possibleSolució
L'escala no s'encén.No power (AC adapter unplugged, batteries dead/incorrectly installed).Comproveu la connexió de l'adaptador de CA. Canvieu les piles, assegurant-vos de la polaritat correcta.
Lectures inexactes o inestables.Scale not on a level surface; item touching something else; overload; environmental factors (vibrations, drafts).Ensure scale is level and stable. Re-zero the scale. Remove any obstructions. Do not exceed capacity.
Display shows "Err" or error code.Overload condition; internal error.Remove weight from platform. Power cycle the scale. If error persists, contact support.
RS-232 communication not working with UPS Worldship.Incorrect scale settings; incorrect computer serial port settings; incorrect Worldship settings; faulty cable.Review Section 6.5 for detailed configuration steps for the scale, computer, and UPS Worldship. Ensure RS-232 cable is securely connected and not damaged.

9. Especificacions

CaracterísticaDetall
ModelLPS150
Capacitat150 lliures (68 kg)
Unitats de pesatgelb, kg, lb/oz
Mostra0.63" (16 mm), 5-digit LCD
Mida de la plataforma15" L x 12" W (381 mm x 305 mm)
ConstruccióStainless Steel Platform, Mild Steel Understructure, Stainless Steel/ABS Indicator
Poder4 x AAA Batteries or 6 VDC AC Adapter (both included)
InterfícieRS-232
Pes de l'article11 lliures (5 kg)
Dimensions del producte17 x 15 x 2.3 polzades (total)

10. Garantia i Suport

Brecknell products are manufactured to high standards and are warranted against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Brecknell weblloc.

For technical assistance, troubleshooting, or spare parts, please contact Brecknell customer support. Have your model number (LPS150) and purchase information ready when contacting support.

Brecknell Contact Information:
Please refer to the official Brecknell weblloc web o l'embalatge del producte per obtenir les dades de contacte més actualitzades.

Documents relacionats - LPS150

Preview Brecknell MS 1000-LCD Operator Manual - Electronic Scale Guide
Comprehensive operator manual for the Brecknell MS 1000-LCD electronic chair scale. This guide covers installation, operation, features like Tare, Hold, BMI, calibration, diagnostics, and technical specifications for accurate weighing.
Preview Brecknell B140 Counting/Coin Scale - Precision Weighing and Counting
Explore the Brecknell B140 Counting/Coin Scale, engineered with Dual Range Technology for superior accuracy across multiple capacities. Ideal for industrial, warehouse, and process control applications, it offers robust construction, versatile features, and clear LED displays.
Preview Bàscula multifunció Brecknell BFS-150: manual d'instruccions i guia de l'usuari
Manual d'instruccions complet per a la bàscula multifunció Brecknell BFS-150. Aprèn sobre les seves característiques, especificacions tècniques, funcionament, manteniment i com interpretar les mesures de greix corporal, aigua, IMC, múscul i ossos.
Preview Brecknell SBI-110 3900LP Bench Scale User Manual
Comprehensive user manual for the Brecknell SBI-110 3900LP Bench Scale. Covers installation, operation, weighing modes, counting, checkweighing, hold mode, menus, calibration, RS232 communication, replacement parts, and loadcell pinouts.
Preview Brecknell PC Series Price Computing Scale Technical Manual
This technical manual provides comprehensive information for the Brecknell PC Series Price Computing Scales (e.g., PC-30, v0.541). It covers installation, operation, parameters, error codes, and specifications for retail environments.
Preview Brecknell DS 1000-LCD Digital Drum Weigher - Operator Manual
This operator manual for the Brecknell DS 1000-LCD digital drum weigher scale provides detailed instructions on installation, operation, features, weighing modes, calibration, and specifications. Essential guide for users of Brecknell weighing equipment.