TOPGREENER TDOS5-JD

Manual d'instruccions de l'interruptor de sensor de moviment de càrrega dual TOPGREENER TDOS5-JD

Model: TDOS5-JD | Brand: TOPGREENER

1. Introducció

This manual provides detailed instructions for the installation, operation, and maintenance of your TOPGREENER TDOS5-JD Dual Load Motion Sensor Switch. This device is designed to automatically control two separate loads, such as lights and a fan, based on occupancy or vacancy detection using Passive Infrared (PIR) technology. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Informació de seguretat

3. Contingut del paquet

4. Característiques del producte

5. Instal·lació

Abans de començar: Ensure power is OFF at the circuit breaker. This device is for single-pole installations only and requires a ground wire.

  1. Apagueu l'alimentació: Locate the circuit breaker controlling the switch you are replacing and turn it OFF. Verify power is off using a voltage provador.
  2. Elimina l'interruptor existent: Carefully remove the wall plate and unscrew the existing switch from the wall box. Disconnect the wires.
  3. Identificar els cables: You should have a Line (hot) wire, two Load wires (one for each load, e.g., light and fan), and a Ground wire. This switch does not require a neutral wire.
  4. Wire the Sensor Switch: Connect the wires from the wall box to the corresponding wires on the TDOS5-JD switch using wire nuts.
    • Connecteu el Line (hot) wire from the wall box to the switch's Line wire.
    • Connecteu el Load 1 wire (e.g., for lights) from the wall box to the switch's Load 1 wire.
    • Connecteu el Load 2 wire (e.g., for fan) from the wall box to the switch's Load 2 wire.
    • Connecteu el Cable de terra from the wall box to the switch's Ground wire.
  5. Muntar l'interruptor: Carefully fold the wires into the wall box and secure the switch with the provided screws. Attach the wall plate.
  6. Restaura l'alimentació: Torneu a encendre l'alimentació a l'interruptor.
  7. Període d'escalfament: After installation, allow 1-2 minutes for the device to warm up and calibrate before it functions correctly.
Diagram of TOPGREENER TDOS5-JD sensor switch components and warm-up instruction

Figura 1: Components of the TDOS5-JD sensor switch, indicating the PIR sensor, Load 1/2 ON/OFF buttons, LED indicator, and a note about the warm-up period after installation. It also highlights that a ground wire is required and no neutral wire is needed.

TOPGREENER TDOS5-JD sensor switch being installed into a wall box

Figura 2: An image showing the TOPGREENER TDOS5-JD motion sensor switch being carefully inserted into a standard electrical wall box during the installation process.

6. Funcionament

Once installed and powered, the TDOS5-JD switch will operate according to the selected mode (Occupancy or Vacancy) and configured settings.

Person carrying laundry basket, demonstrating hands-free lighting with the sensor switch

Figura 3: A person carrying a laundry basket walks into a room, and the lights automatically turn on, illustrating the hands-free lighting capability of the motion sensor switch.

Bathroom with lights and fan controlled by the dual load sensor switch

Figura 4: A modern bathroom setting where the TOPGREENER dual load sensor switch controls both the overhead lights and the exhaust fan automatically, demonstrating its energy-saving potential.

7. Customization and Settings

The TDOS5-JD switch offers adjustable settings for time delay, sensitivity (range), and operating mode. These settings are located behind the faceplate.

  1. Configuració d'accés: Gently pry open the outer cover of the switch to reveal the adjustment dials and mode switch.
  2. Ajustar el retard de temps: Use a small screwdriver to turn the 'TIME' dial to select the desired delay: Test (15 seconds), 5 minutes, 10 minutes, 20 minutes, or 30 minutes.
  3. Adjust Sensor Range: Use a small screwdriver to turn the 'RANGE' dial to adjust the motion detection sensitivity from 1 (lowest) to 4 (highest).
  4. Seleccioneu el mode de funcionament: Use the small switch labeled 'OCCD OCCS VACD' to choose your desired mode:
    • OCCD: Dual Occupancy Mode
    • OCCS: Single Occupancy Mode
    • VACD: Modalitat vacant
Diagram showing how to adjust timer, range, and mode on the sensor switch

Figura 5: A detailed diagram illustrating the steps to customize the sensor switch settings. It shows how to open the cover, and then adjust the 'Time' dial (Test, 5, 10, 20, 30 Min), 'Range' dial (1-4), and the 'Mode Select' switch (OCCD, OCCS, VACD).

Bathroom scene with a close-up of the sensor switch's adjustable time delay settings

Figura 6: An image depicting a modern bathroom with the sensor switch installed on the wall. A magnified inset shows the adjustable time delay and range dials, emphasizing the customization options for automatic light control.

8. Solució De Problemes

ProblemaCausa possibleSolució
Lights/Fan do not turn ON with motion.No power; incorrect wiring; sensor blocked; incorrect mode; range too low.Check circuit breaker. Verify wiring connections. Ensure sensor lens is clear. Confirm correct operating mode (OCCS/OCCD). Increase sensor range.
Lights/Fan stay ON too long or turn OFF too quickly.Incorrect time delay setting; continuous motion detected; walk-through feature activated.Adjust time delay setting. Ensure no constant motion within sensor's view. Understand walk-through feature behavior.
Lights/Fan turn ON without apparent motion (false triggers).Sensor too sensitive; heat sources or air drafts; sensor facing high-traffic area.Decrease sensor range. Relocate sensor away from heat sources (HVAC vents, direct sunlight) or drafts. Adjust sensor direction if possible.
Timer not functioning as expected (e.g., only extreme settings work).Dial mechanism issue; specific unit calibration.Carefully re-adjust the time dial. If issue persists, contact customer support.
One load works, but the other does not.Incorrect wiring for the non-working load; faulty bulb/fan.Verify wiring connections for Load 1 and Load 2. Test the bulb or fan directly to ensure it is functional.

9. Especificacions

10. Manteniment

The TOPGREENER TDOS5-JD motion sensor switch requires minimal maintenance.

11. Garantia i Suport

TOPGREENER products are designed for reliability and performance. For specific warranty information, including terms and conditions, please refer to the warranty documentation provided with your purchase or visit the official TOPGREENER website. For technical support or assistance with troubleshooting, please contact TOPGREENER customer service.

Fabricant: TOPGREENER

Informació de contacte: Please visit the TOPGREENER official weblloc web per obtenir les dades de contacte i els recursos d'assistència més actualitzats.

Documents relacionats - TDOS5-JD

Preview Guia d'instal·lació de l'interruptor de sensor d'ocupació/vacant Topgreener TDOS5/TDOS5-NL
Guia d'instal·lació completa per a l'interruptor de sensor d'ocupació/vacant 2 en 1 Topgreener TDOS5/TDOS5-NL. Inclou especificacions, diagrames de cablejat, configuracions d'ajust, modes de funcionament, consells per a la resolució de problemes i informació sobre la garantia.
Preview Guia d'instal·lació del sensor de moviment PIR d'humitat de doble tecnologia TOPGREENER TDHOS5
Guia completa d'instal·lació i programació per al sensor d'humitat i moviment PIR de doble tecnologia TOPGREENER TDHOS5. Cobreix el cablejat, la configuració, les característiques, la resolució de problemes i la garantia per a un control òptim de la llum i el ventilador del bany.
Preview Instruccions d'instal·lació del regulador d'intensitat LED TGSDS3 de Top Greener
Guia d'instal·lació completa per al regulador d'intensitat LED Top Greener TGSDS3, que detalla el cablejat unipolar i de 3 vies, les especificacions del producte, les instruccions de funcionament i la informació de la garantia.
Preview Instruccions d'instal·lació de l'interruptor del sensor de presència TopGreener TSOS5/TWOS5
Instruccions d'instal·lació detallades per als interruptors de sensor d'ocupació TopGreener TSOS5 i TWOS5, incloent-hi especificacions, diagrames de cablejat, funcionament, resolució de problemes i informació sobre la garantia.
Preview Guia d'instal·lació del control de ventilador amb sensor d'humitat TOPGREENER TDHS5
Instruccions d'instal·lació completes i guia d'usuari per al control de ventilador amb sensor d'humitat TOPGREENER TDHS5. Apreneu a cablejar, programar i fer funcionar el control de ventilador amb sensor d'humitat per a una ventilació òptima del bany.
Preview Guia d'instal·lació i configuració del regulador d'intensitat Wi-Fi TOPGREENER TGWF500D
Guia completa d'instal·lació i configuració del regulador d'intensitat intel·ligent per a la domòtica sense fils TOPGREENER TGWF500D. Apreneu a connectar-vos al Wi-Fi i a fer funcionar el vostre regulador d'intensitat intel·ligent.