1. Introducció
The Honeywell TH6100AF2004 T6 Pro-1 Heat Slab Sensor Thermostat is designed to provide precise temperature control for heating systems, particularly those utilizing slab or floor heating. This thermostat offers flexible climate control options, allowing management of ambient air temperature, floor temperature, or a combination of both with defined limits. Its programmable features contribute to energy efficiency and enhanced comfort.

2. Característiques clau
- 1-Stage Heat Only: Designed for single-stage sistemes de calefacció.
- Flexible Climate Control:
- Ambient Air Temperature (A): Controls based on room air temperature.
- Floor Temperature (F): Controls based on the temperature of the floor slab using a remote sensor.
- Air Temperature with Min/Max Floor Limits (AF): Controls air temperature while maintaining floor temperature within specified minimum and maximum limits for comfort and floor protection.
- Antifreeze Temperature Protection: Prevents pipes from freezing in unoccupied spaces.
- Boiler Short Cycling Protection: Extends the life of heating equipment.
- Opcions programables: Supports 7-day, 5-2-day, or 5-1-1-day scheduling, or non-programmable operation.
- Vacation Hold Settings: Allows for extended temperature holds during absences.
- Mode econòmic: Overrides floor low limit settings during 'away' and 'sleep' periods to conserve energy.
- Pantalla LCD gran: Pantalla clara i fàcil de llegir.
- Control de botó: Intuitive interface for adjustments.

3. Contingut del paquet
Comproveu que el vostre paquet contingui els elements següents:
- Honeywell TH6100AF2004 T6 Pro-1 Thermostat
- Universal Mounting Plate (UWP)
- Adaptador d'instal·lació estàndard (adaptador de caixa J)
- Cover Plate (for covering old thermostat marks)
- Maquinari de muntatge (cargols, ancoratges)
- Floor Temperature Sensor (wired)
- Tornavís

4. Configuració i instal·lació
4.1. Informació de seguretat
ADVERTÈNCIA: Risc elèctric.
Disconnect power at the circuit breaker or fuse box before installation to prevent electrical shock or equipment damage. Installation should be performed by a qualified technician. Read all instructions carefully before proceeding.
4.2. Cablatge
The TH6100AF2004 thermostat is designed for 24V AC systems. Ensure your heating system is compatible. Refer to your heating system's manual for specific wiring diagrams. Connect wires to the Universal Wiring Plate (UWP) terminals as indicated in the thermostat's wiring diagram. The floor sensor connects to the 'S1' and 'S2' terminals.

4.3. Muntatge
- Turn off power to your heating system at the circuit breaker.
- Traieu el vostre termòstat antic.
- Mount the UWP to the wall using the provided screws and anchors. Ensure it is level.
- Route the floor sensor cable to the desired location in the floor slab and connect it to the S1 and S2 terminals on the UWP.
- Connect the system wires to the appropriate terminals on the UWP.
- Align the thermostat with the UWP and push it firmly until it snaps into place.
- Restableix l'electricitat al teu sistema de calefacció.
5. Instruccions de funcionament
5.1. Mostra mésview
The large LCD display shows the current temperature, setpoint temperature, time, system mode, and fan status. Buttons below the display allow for mode selection, menu access, and temperature adjustments.

5.2. Configuració de la temperatura
To adjust the setpoint temperature, use the + or - buttons located below the display. The display will show the new setpoint briefly before returning to the current temperature.
5.3. Mode Selection (Heat, Off)
Premeu el botó Mode botó per anar canviant pels modes de sistema disponibles: Calor i Apagat. Seleccioneu Calor for active heating or Apagat per desactivar el sistema de calefacció.
5.4. Calendari de programació
The thermostat supports programmable schedules (7-day, 5-2-day, 5-1-1-day) or non-programmable operation. Access the Menú to configure your desired schedule. Follow the on-screen prompts to set specific temperatures for different times of the day and days of the week (e.g., Wake, Away, Home, Sleep periods).
5.5. Floor Temperature Control Options
The thermostat offers three control options, configurable in the installer setup menu:
- A (Ambient Air Temperature): The thermostat controls based solely on the air temperature sensor. The floor sensor is not actively used for control.
- F (Floor Temperature): The thermostat controls based solely on the floor sensor. The air temperature sensor is not actively used for control.
- AF (Ambient Air Temperature with Min/Max Floor Limits): The thermostat primarily controls based on the air temperature sensor, but will activate heating if the floor temperature drops below a set minimum limit, or deactivate if it exceeds a set maximum limit. This protects the floor and enhances comfort.
6. Manteniment
6.1. Neteja
Netegeu l'exterior del termòstat amb un drap suau iamp drap. No utilitzeu productes de neteja abrasius ni dissolvents. Eviteu ruixar líquids directament sobre el termòstat.
6.2. Sensor Care
The floor temperature sensor is typically embedded in the floor slab and requires no direct maintenance. Ensure the sensor cable is not damaged during installation or subsequent floor work. If the sensor is exposed, keep it clean and free from debris.
7. Solució De Problemes
Si teniu problemes amb el termòstat, consulteu els problemes i solucions més comuns següents:
- Sense pantalla/pantalla en blanc:
- Check the circuit breaker and ensure power is supplied to the heating system and thermostat.
- Verify that the thermostat is properly seated on the UWP.
- Heating Not Turning On:
- Ensure the system mode is set to Calor.
- Increase the setpoint temperature above the current room temperature.
- Check for error messages on the display.
- Verify wiring connections at the UWP.
- Lectures de temperatura inexactes:
- Assegureu-vos que el termòstat no estigui exposat a la llum solar directa, corrents d'aire ni fonts de calor.
- If using a floor sensor, ensure it is correctly installed and not damaged.
- Thermostat Not Responding to Button Presses:
- A temporary power cycle (turn off power at breaker for 30 seconds, then restore) may resolve the issue.
If problems persist after attempting these troubleshooting steps, contact customer support.
8. Especificacions
| Característica | Especificació |
|---|---|
| Marca | Honeywell |
| Nom del model | Honeywell T6 Pro-1 |
| Número de model | TH6100AF2004 |
| Tipus de controlador | Pulsador |
| Característica especial | 7-day, 5-2-day, 5-1-1-day programmable or non-programmable |
| Color | Blanc |
| Usos específics per al producte | Boiler, Heat Slab |
| Tipus de control de temperatura | Auto, Heat, Off |
| Tecnologia de connectivitat | Amb cable |
| Components inclosos | Thermostat, Floor Sensor |
| Font d'alimentació | CA/CC (24 volts) |
| Pes de l'article | 13 unces (0.81 lliures) |
| Dimensions del producte | 15.75 x 12.95 x 6.35 polzades |
| Tipus de visualització | LCD |
| Tipus de muntatge | Muntatge de paret |

9. Garantia i Suport
9.1. Informació de la garantia
This Honeywell product is covered by a limited warranty. For specific details regarding warranty coverage, duration, and terms, please refer to the warranty card included with your product or visit the official Honeywell weblloc web. Conserveu el comprovant de compra per a reclamacions de garantia.
9.2. Atenció al client
For technical assistance, troubleshooting guidance beyond this manual, or warranty inquiries, please contact Honeywell Customer Support. Contact information can typically be found on the product packaging, the official Honeywell website, or by calling the number provided in your product documentation.