Producte acabatview
The EDM 02566 is a 1-pole + neutral magnetothermic circuit breaker designed for electrical installations. This narrow, white circuit breaker is rated at 16A and provides essential protection against overcurrents and short circuits in your electrical system. Its compact design makes it suitable for various distribution boards.
Les característiques clau inclouen:
- 1-Pole + Neutral configuration
- 16 Ampere (16A) current rating
- Magnetothermic protection mechanism
- Compact, narrow design
- White color finish
- Manufactured by Edp
Informació important de seguretat
WARNING: Electrical work should only be performed by qualified and licensed electricians. Failure to follow these instructions can result in electric shock, fire, serious injury, or death.
- Always disconnect power at the main service panel before installing, servicing, or removing this device.
- Comproveu que l'alimentació estigui apagada amb un voltage provador abans de continuar.
- Ensure the circuit breaker's rating (16A) matches the requirements of your electrical circuit.
- No utilitzeu aquest dispositiu si sembla malmès.
- Compliu tots els codis i regulacions elèctriques locals i nacionals.
- Aquest producte està dissenyat només per a ús interior en llocs secs.
Guia d'instal·lació
Follow these steps carefully for the correct installation of your EDM 02566 Magnetothermic Circuit Breaker. Ensure all safety precautions are observed.
- Preparació: Turn off the main power supply to the electrical panel where the circuit breaker will be installed. Use a voltage tester to confirm that the power is completely off.
- Identify Breaker Slot: Locate an available slot on the DIN rail within your electrical distribution board.
- Muntatge: Position the circuit breaker onto the DIN rail. Press firmly until it clicks securely into place.
- Wiring - Input (Top Terminals):
Connect the incoming live (L) wire to the top terminal marked 'L' (or the un-marked terminal on the right, as per typical wiring diagrams for this type of breaker). Connect the incoming neutral (N) wire to the top terminal marked 'N'. Ensure wires are stripped to the correct length and securely fastened by tightening the screw terminals. Refer to the wiring diagram below for clarity.

Figura 1: Wiring Diagram. The diagram illustrates the connection points for the incoming (Entrada) and outgoing (Salida) Live (L) and Neutral (N) wires. The 'N' terminal is clearly marked for the neutral connection.
- Wiring - Output (Bottom Terminals):
Connect the outgoing live (L) wire for the circuit you are protecting to the bottom terminal corresponding to the live input. Connect the outgoing neutral (N) wire to the bottom terminal marked 'N'. Tighten all screw terminals firmly to prevent loose connections, which can cause overheating.
- Verifica les connexions: Double-check all wiring connections to ensure they are correct and secure.
- Restaura l'alimentació: Un cop finalitzada i verificada la instal·lació, restableu l'alimentació al quadre de servei principal.

Figura 2: EDM 02566 Circuit Breaker. This image shows the front of the circuit breaker, including the ON/OFF switch, terminal screws, and product labeling.
Funcionament
The EDM 02566 Magnetothermic Circuit Breaker operates automatically to protect electrical circuits from damage caused by overcurrent or short circuit. It also provides a manual means to disconnect power to a circuit.
- Posició ON: Push the switch lever upwards to the 'ON' position to allow current to flow through the circuit.
- Posició OFF: Push the switch lever downwards to the 'OFF' position to manually disconnect power to the circuit.
- Posició disparada: If an overcurrent or short circuit occurs, the breaker will automatically trip to an intermediate or 'OFF' position (depending on the specific mechanism). This indicates a fault in the circuit.
- Reinici d'un interruptor automàtic disparat: To reset a tripped breaker, first identify and resolve the cause of the trip (e.g., unplug overloaded devices). Then, firmly push the switch lever completely to the 'OFF' position before pushing it back to the 'ON' position. If the breaker immediately trips again, do not attempt to reset it repeatedly; consult a qualified electrician.
Manteniment
Magnetothermic circuit breakers like the EDM 02566 are generally maintenance-free. However, periodic checks can help ensure their continued reliable operation:
- Inspecció visual: Inspeccioneu periòdicament l'interruptor automàtic per detectar qualsevol signe de danys físics, decoloració o connexions soltes.
- Neteja: Ensure the area around the circuit breaker is free from dust and debris, which can impede proper heat dissipation.
- Testing (Professional Only): For critical installations, professional electricians may perform periodic testing of circuit breakers using specialized equipment. Do not attempt to test the breaker by intentionally creating a short circuit.
- Estrènyer les connexions: Over time, screw terminals can loosen. A qualified electrician can periodically check and re-tighten terminal screws, ensuring power is off before doing so.
Resolució de problemes
If you encounter issues with your EDM 02566 Magnetothermic Circuit Breaker, consider the following common scenarios:
- Freqüència de salts de l'interruptor:
This is usually an indication of an overloaded circuit or a short circuit. Unplug or turn off some devices connected to the circuit. If the problem persists, there might be a fault in the wiring or an appliance. Consult a qualified electrician.
- L'interruptor no es reinicia:
Ensure you are pushing the lever fully to the 'OFF' position before attempting to push it to 'ON'. If it still doesn't reset or immediately trips again, there is likely a persistent fault on the circuit. Do not force the breaker. Seek professional electrical assistance.
- Sense alimentació al circuit (interruptor activat):
Check if the main breaker for the entire panel is ON. Verify all connections to the circuit breaker are secure. If power is still not restored, there might be an issue with the wiring or the breaker itself. Contact a qualified electrician.
- El trencador té molta calor:
A warm breaker can be normal under load, but if it's excessively hot to the touch, it could indicate an overload, loose connection, or an internal fault. Immediately turn off the circuit at the main panel and have it inspected by an electrician.
Especificacions tècniques
| Especificació | Valor |
|---|---|
| Fabricant | Edp |
| Número de part | 02566 |
| Pes de l'article | 3.52 unces |
| Dimensions del producte | 3.94 x 2.76 x 1.97 polzades |
| Número de model de l'article | 02566 |
| Color | blanc |
| Quantitat de paquet d'articles | 1 |
| Piles incloses? | No |
| Necessites piles? | No |
| ASIN | B079KM9X7Q |
| Data de primera disponibilitat | 3 de febrer de 2018 |
Garantia i Suport
For specific warranty information regarding your EDM 02566 Magnetothermic Circuit Breaker, please refer to the documentation provided with your purchase or contact the manufacturer directly. As a general guideline, most electrical components come with a limited manufacturer's warranty covering defects in materials and workmanship.
For technical support, installation queries, or troubleshooting assistance beyond this manual, it is highly recommended to contact a qualified and licensed electrician. Do not attempt repairs or modifications yourself if you are not qualified.
Manufacturer Contact (General): www.edm.es (Please note: This is a general link to the brand's weblloc web i potser no condueix directament a assistència per a aquest producte específic.)