1. Introducció
This manual provides essential information for the safe and efficient operation of your APC SMT1500RMI2UC Line-Interactive 1500VA Uninterruptible Power Supply (UPS). The UPS is designed to protect your electronic equipment from power outages, surges, and sags, ensuring continuous power and data integrity. Please read this manual thoroughly before installation and use.
2. Informació de seguretat
WARNING: Risk of Electric Shock or Explosion
- This UPS contains internal batteries that may present a shock hazard even when disconnected from the utility power.
- El manteniment de les bateries ha de ser realitzat o supervisat per personal coneixedor de les bateries i de les precaucions necessàries.
- Do not dispose of batteries in a fire. Batteries may explode.
- No obriu ni mutileu les bateries. L'electròlit alliberat és nociu per a la pell i els ulls. Pot ser tòxic.
- Ensure proper grounding of the UPS and connected equipment.
- Do not operate the UPS in direct sunlight, in contact with fluids, or where there is excessive dust or humidity.
3. Producte acabatview
3.1 Tauler frontal

Figura 3.1: Frontal view of the APC SMT1500RMI2UC UPS, showing the LCD display and control buttons.
The front panel features an intuitive LCD display and control buttons for monitoring UPS status, configuring settings, and performing self-tests. The display provides real-time information on load, battery charge, and operational status.

Figure 3.2: Close-up of the UPS LCD display, indicating 0% load and 100% battery charge.
3.2 Panell posterior

Figura 3.3: posterior view of the UPS, highlighting the input power connector, six IEC-C13 output outlets, communication ports, and battery connector.
The rear panel includes the main power input, six IEC-C13 output outlets for connecting protected equipment, and various communication ports. An overload protector button is also present for resetting in case of an electrical overload.

Figura 3.4: Detallada view of the USB, Serial, and Network (SmartConnect) communication ports.
3.3 SmartConnect Feature
The APC SMT1500RMI2UC features SmartConnect, allowing for cloud-based remote monitoring and management of your UPS. This enables you to receive alerts, monitor status, and perform basic management tasks from any web-dispositiu habilitat.

Figure 3.5: The APC SmartConnect dashboard accessible across various devices for remote monitoring.
4. Configuració
4.1 Desembalatge i inspecció
Carefully unpack the UPS and inspect it for any shipping damage. Report any damage to the carrier and your dealer. Retain the packing materials for future use.
4.2 Connexió de la bateria
The UPS is shipped with the internal battery disconnected for safety. Before initial use, connect the battery according to the instructions provided in the quick start guide or on the unit itself. This typically involves pulling out the battery tray, rotating the battery, and pushing it back in until it clicks into place.
4.3 Col·locació i muntatge
The SMT1500RMI2UC is designed for rack-mount installation. Ensure adequate ventilation around the unit. Avoid placing the UPS near heat sources or in areas with excessive dust or moisture.

Figure 4.1: The UPS securely installed within a standard server rack.
4.4 Equips de connexió
- Connect the UPS to a properly grounded utility power outlet using the provided power cord.
- Connect your critical equipment (servers, network devices, etc.) to the IEC-C13 output outlets on the rear of the UPS. Ensure the total load does not exceed the UPS's capacity.
- For remote monitoring, connect an Ethernet cable from your network to the SmartConnect network port on the rear panel.
4.5 Engegada inicial
Press the power button on the front panel to turn on the UPS. The LCD display will illuminate, and the UPS will perform a self-test. Allow the UPS to charge for at least 24 hours before relying on its full battery runtime capacity.
5. Funcionament
5.1 Engegada/apagada
- Per encendre: Premeu i manteniu premut el botó d'engegada fins que la pantalla s'il·lumini.
- Per apagar: Premeu i manteniu premut el botó d'engegada fins que la pantalla s'apagui.
Pantalla LCD 5.2 i navegació
The LCD display provides real-time status information. Use the navigation buttons (up, down, enter, escape) to browse through menus, view detailed information, and adjust settings such as output voltage, alarm thresholds, and self-test schedules.
5.3 Volum automàtictagReglament (AVR)
The UPS features Automatic Voltage Regulation (AVR) to correct minor voltage fluctuations without switching to battery power. This extends battery life and ensures a stable power supply to connected equipment.
5.4 Green Mode
The Green Mode feature optimizes UPS efficiency by bypassing the AVR when utility power is stable, reducing energy consumption and heat generation. The UPS automatically switches to AVR or battery mode when power conditions require it.
5.5 SmartConnect Monitoring
Once connected to your network, register your UPS with the APC SmartConnect portal. This allows you to monitor the UPS status, receive email alerts for critical events, and perform remote diagnostics via a secure web interface or mobile application.
6. Manteniment
6.1 Battery Care and Replacement
The internal battery has a typical lifespan of 3-5 years. Regular self-tests help monitor battery health. When the battery needs replacement, the UPS will indicate this on the LCD and via SmartConnect. Replace batteries with APC-approved replacement battery cartridges (RBCs) to ensure optimal performance and safety.
6.2 actualitzacions de microprogramari
Periodically check for firmware updates through the SmartConnect portal or APC's website. Firmware updates can provide performance enhancements, bug fixes, and new features. Follow the provided instructions carefully when performing updates.
6.3 Neteja
Keep the UPS free from dust and debris. Use a dry cloth to clean the exterior. Do not use liquid cleaners or solvents.
7. Solució De Problemes
Si teniu problemes amb el vostre SAI, consulteu els següents problemes i solucions habituals:
| Problema | Causa possible | Solució |
|---|---|---|
| El SAI no s'encén | Battery not connected; No utility power; Faulty power cord | Ensure battery is connected; Check utility power; Verify power cord connection. |
| UPS beeps frequently | On battery power; Low battery; Overload | Check utility power; Allow battery to charge; Reduce connected load. |
| Indicador de sobrecàrrega activat | Too much equipment connected | Disconnect non-essential equipment; Press the overload protector reset button on the rear panel. |
| La bateria necessita substitució | La bateria ha arribat al final de la vida útil | Order and install a new APC replacement battery cartridge. |
For more detailed troubleshooting, consult the full product documentation available on the APC website or through the SmartConnect portal.
8. Especificacions
Key technical specifications for the APC SMT1500RMI2UC UPS:
- Model: SMT1500RMI2UC
- Capacitat: 1500 VA / 1000 W
- Entrada Voltage: 230 Volts
- Output Outlets: 6 x IEC-C13
- Dimensions (A x A x P): 3.39 x 17.01 x 18.78 polzades (8.6 x 43.2 x 47.7 cm)
- Pes de l'article: 57.2 lliures (26 quilograms)
- Tipus de bateria: 1 x A battery (included)
- Ports de comunicació: USB, Serial, Network (SmartConnect)
- Color: Negre
- Data de primera disponibilitat: 3 d'abril de 2018

Figure 8.1: Runtime graph illustrating the estimated battery backup time based on connected load for the SMT1500RMI2UC model.
9. Garantia i Suport
For warranty information and technical support, please refer to the official APC by Schneider Electric weblloc web o contacteu amb el seu servei d'atenció al client. Mantingueu a mà el rebut de compra i el número de sèrie del producte quan contacteu amb el servei d'assistència.
You can find additional resources and support through the Botiga APC by Schneider Electric a Amazon.