1. Introducció
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Red Lion Controls/N-Tron PAXD0000 Universal DC Input Meter. Please read this manual thoroughly before using the device and retain it for future reference.
The PAXD0000 is designed for universal DC input measurement applications, offering reliable performance in industrial environments.
2. Informació de seguretat
Always observe standard safety precautions during installation and operation. Failure to comply with safety warnings may result in injury or damage to the equipment.
- Ensure power is disconnected before performing any wiring or maintenance.
- La instal·lació i el manteniment només els ha de dur a terme personal qualificat.
- No feu servir el dispositiu en entorns que superin les condicions de funcionament especificades.
- Protegiu el dispositiu de la humitat, la pols i les temperatures extremes.
3. Producte acabatview
The Red Lion PAXD0000 Universal DC Input Meter features a clear digital display and intuitive control buttons for easy configuration and monitoring.
Figure 1: Front panel of the PAXD0000 meter. This image shows the front panel of the PAXD0000 meter, featuring a red digital display showing '67.4 %' and five control buttons labeled DSP, PAR, F1, F2, and RST.
Components del panell frontal:
- Pantalla digital: High-visibility red LED display for showing measured values and menu parameters.
- Botó DSP: Used for display functions and navigating through display modes.
- PAR Button: Used for accessing and setting parameter configurations.
- Botó F1: Function button 1, typically for specific user-defined actions or menu navigation.
- Botó F2: Function button 2, typically for specific user-defined actions or menu navigation.
- Botó RST: Reset button, used for resetting values or confirming selections.
4. Configuració
4.1. Instal·lació
The PAXD0000 is designed for panel mounting. Ensure adequate space for ventilation and wiring connections.
- Cut a panel cutout of the specified dimensions (refer to the product datasheet for exact measurements).
- Insert the meter into the cutout from the front.
- Secure the meter using the provided mounting clips from the rear of the panel.
4.2. Cablatge
Refer to the wiring diagram provided with your device for specific terminal connections. Ensure all connections are secure and correctly polarized.
- Font d'alimentació: Connect the appropriate DC power supply to the designated power terminals. Verify voltage compatibilitat.
- Senyal d'entrada: Connect the DC input signal to the input terminals. Observe polarity for accurate readings.
- Output Connections (if applicable): If your model includes output options (e.g., relays, analog output), connect them according to your system requirements.
4.3. Encès
Once all wiring is complete and verified, apply power to the device. The display should illuminate, and the meter will perform a self-test before showing the measured value.
5. Instruccions de funcionament
5.1. Basic Measurement Display
Upon power-up, the meter will typically display the primary measured DC input value. Use the DSP button to cycle through various display modes, such as minimum, maximum, or other configured values.
5.2. Configuració de paràmetres
To access and modify device parameters:
- Premeu el botó PAR botó per entrar al menú de paràmetres.
- Utilitza el F1 i F2 buttons to navigate through the parameters.
- Premeu RST to select a parameter for editing.
- Ús F1 i F2 per canviar el valor del paràmetre.
- Premeu RST again to confirm the new value and save it.
- Premeu PAR per sortir del menú de paràmetres.
Common parameters include input scaling, decimal point position, and alarm setpoints. Refer to the detailed programming guide for a complete list of parameters and their functions.
6. Manteniment
6.1. Neteja
Netegeu el panell frontal amb un suau, damp cloth. Do not use abrasive cleaners or solvents, as these may damage the display or housing.
6.2. Calibració
The PAXD0000 is factory calibrated. If recalibration is required, refer to the advanced programming manual or contact Red Lion technical support. Recalibration should only be performed by trained personnel using certified equipment.
7. Solució De Problemes
This section provides solutions to common issues. For problems not listed here, contact technical support.
| Problema | Causa possible | Solució |
|---|---|---|
| La pantalla està en blanc | No power, incorrect wiring, or power supply failure. | Check power connections and supply voltage. Verify wiring against the diagram. |
| Lectures incorrectes | Incorrect input wiring, scaling errors, or sensor issue. | Verify input wiring polarity. Check parameter settings for scaling. Test input signal with a known source. |
| Els botons no responen | Temporary software glitch or physical damage. | Cycle power to the device. If problem persists, contact support. |
8. Especificacions
| Característica | Detall |
|---|---|
| Model | PAXD0000 |
| Marca | Red Lion |
| Fabricant | Controls Red Lion |
| Tipus d'entrada | Universal DC Input |
| ASIN | B07CZLSTMV |
| UPC | 747356317894 |
| Data de primera disponibilitat | 10 de maig de 2018 |
For complete technical specifications, refer to the official product datasheet available on the Red Lion weblloc.
9. Informació de la garantia
Red Lion Controls products are typically covered by a limited warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary by region and product. Please refer to the official Red Lion Controls warranty statement available on their website or contact your local distributor for detailed information.
Conserveu el comprovant de compra per a reclamacions de garantia.
10. Suport
For technical assistance, troubleshooting, or further information regarding the PAXD0000 Universal DC Input Meter, please contact Red Lion Controls technical support.
You can also visit the official Red Lion website for product documentation, FAQs, and contact details. For general inquiries or to explore other products, visit the Red Lion Store on Amazon.