1. Producte acabatview
The ABB Tmax XT4NU3250EFF000XXX is a high-performance molded case circuit breaker designed for reliable protection in various electrical systems. This device features a frame size XT4, rated for up to 250A, with voltage ratings of 600V (UL) and 690V (IEC). It incorporates an Ekip LS/I electronic trip unit, providing Long-Time (L), Short-Time (S), and Instantaneous (I) protection functions. This 3-pole circuit breaker is engineered for safety and efficiency in industrial and commercial applications.

An image showing the ABB Tmax XT4NU3250EFF000XXX Molded Case Circuit Breaker. The device is dark gray with a red and white handle, indicating its operational status. Various labels and connection points are visible on its front and sides.
2. Informació de seguretat
Observeu sempre les següents precaucions de seguretat per evitar lesions o danys a l'equip:
- Installation, maintenance, and repair must be performed by qualified personnel only.
- Ensure all power sources are disconnected and locked out before working on the circuit breaker or associated circuitry.
- Use appropriate personal protective equipment (PPE) such as insulated gloves, safety glasses, and arc-flash protective clothing.
- Comproveu el vol correctetage i classificacions actuals abans de la instal·lació.
- Do not operate the circuit breaker if it appears damaged or malfunctioning.
3. Configuració i instal·lació
The ABB Tmax XT4NU3250EFF000XXX circuit breaker is designed for DIN Rail Mount installation. Proper installation is crucial for safe and reliable operation.
3.1 Comprovacions prèvies a la instal·lació
- Inspect the circuit breaker for any physical damage.
- Confirm that the product specifications match the system requirements.
- Ensure the mounting surface is clean and secure.
3.2 Muntatge
- Securely attach the circuit breaker to a standard DIN rail.
- Assegureu-vos una ventilació adequada al voltant del dispositiu per evitar el sobreescalfament.
3.3 Cablejat
- Connect the main power supply conductors to the appropriate terminals (Line/Load) as indicated on the device.
- Ensure all connections are tight and secure to prevent loose contacts and arcing.
- Follow all local and national electrical codes for wiring practices.
- Verify correct polarity and phase sequence for multi-phase installations.
4. Instruccions de funcionament
The ABB Tmax XT4NU3250EFF000XXX circuit breaker is designed for straightforward operation.
4.1 Activació / desactivació
- To Switch ON: Push the operating handle firmly to the 'ON' position.
- To Switch OFF: Push the operating handle firmly to the 'OFF' position.
4.2 Trip Indication and Reset
- If an overload or short-circuit occurs, the circuit breaker will automatically trip, moving the handle to an intermediate 'TRIPPED' position.
- Per restablir: First, move the handle fully to the 'OFF' position. Then, push the handle to the 'ON' position.
- Before resetting, investigate and resolve the cause of the trip. Repeated tripping indicates an underlying electrical issue.
5. Manteniment
Regular maintenance ensures the longevity and reliable operation of your circuit breaker.
5.1 Inspecció rutinària
- Inspeccioneu periòdicament l'interruptor automàtic per detectar qualsevol signe de danys físics, decoloració o connexions soltes.
- Check for dust accumulation and keep the area around the breaker clean.
5.2 Neteja
- Ensure power is disconnected before cleaning.
- Use a dry, lint-free cloth to wipe down the exterior of the circuit breaker. Avoid using solvents or abrasive cleaners.
5.3 Servei professional
For internal inspection, testing, or repair, contact qualified ABB service personnel or an authorized service center. Do not attempt to disassemble the circuit breaker yourself.
6. Solució De Problemes
Aquesta secció ofereix orientació per a problemes comuns. Per a problemes complexos, consulteu un electricista qualificat.
6.1 Breaker Trips Frequently
- Possible causa: Sobrecàrrega.
- Acció: Reduce the load on the circuit by unplugging some devices.
- Possible causa: Curtcircuit.
- Acció: Inspect wiring and connected devices for faults. This requires professional attention.
- Possible causa: Ground fault (if applicable to the specific trip unit configuration).
- Acció: Consult a qualified electrician to identify and rectify the ground fault.
6.2 Breaker Will Not Reset
- Possible causa: Persistent fault (overload or short circuit).
- Acció: Ensure the cause of the trip has been resolved. If the fault persists, the breaker will not reset.
- Possible causa: Internal damage to the breaker.
- Acció: If no fault is present and the breaker still won't reset, it may be damaged and require replacement by a qualified professional.
7. Especificacions
Detailed technical specifications for the ABB Tmax XT4NU3250EFF000XXX Molded Case Circuit Breaker:
| Especificació | Valor |
|---|---|
| Marca | FIG |
| Model | XT4NU3250EFF000XXX |
| Valoració actual | 250 Amps |
| Voltage Rating (UL) | 600 V |
| Voltage Rating (IEC) | 690 V |
| Tipus de viatge | Ekip LS/I (Electronic, LS/I Protection) |
| Nombre de pols | 3 |
| Tipus d'interruptor | LS |
| Tipus de muntatge | Muntatge sobre carril DIN |
| Dimensions del paquet | 8.26 x 6.49 x 6.1 polzades |
| Pes | 5.51 lliures |
| Data de primera disponibilitat | 25 de juny de 2018 |
8. Informació de la garantia
ABB products are manufactured to high standards and typically come with a manufacturer's warranty. For specific warranty terms and conditions applicable to your ABB Tmax XT4NU3250EFF000XXX circuit breaker, please refer to the official documentation provided with your purchase or visit the official ABB weblloc web. Conserveu el comprovant de compra per a reclamacions de garantia.
9. Suport i contacte
For technical assistance, product inquiries, or service requests, please contact ABB customer support. You can find contact information and additional resources on the official ABB weblloc.
Oficial d'ABB Weblloc: Visit the ABB Store on Amazon