1. Introducció
The Veanic Mini Digital Temperature Humidity Meter is designed to provide accurate and real-time measurements of both temperature and humidity in various indoor environments. Its compact size makes it suitable for monitoring conditions in diverse locations such as reptile tanks, guitar cases, greenhouses, cellars, refrigerators, and closets. This manual provides essential information for the proper setup, operation, and maintenance of your device.

Figura 1: Mésview of the Veanic Mini Digital Temperature Humidity Meters.
2. Característiques del producte
- Funcionalitat 2 en 1: Measures both temperature and humidity.
- Disseny compacte: Mini size (1.89" x 1.13" x 0.6" / 48mm x 28mm x 15mm) for versatile placement.
- Pantalla LCD digital: Clear and easy-to-read display in Fahrenheit (℉).
- Ampli rang de mesura: Temperature from -58℉ to 158℉; Humidity from 10% to 99% RH.
- Alta precisió: Temperature accuracy of ±2℉; Humidity accuracy of ±5% RH.
- Frequent Sampling: Measures conditions every 10 seconds for up-to-date readings.
- Llarga vida útil de la bateria: Powered by 2 LR44 button batteries, providing 12-18 months of operation.
Figure 2: Compact dimensions of the meter.
3. Configuració
The Veanic Mini Digital Temperature Humidity Meter comes with batteries pre-installed. However, if you need to replace them or ensure they are correctly seated, follow these steps:
- Localitzeu el compartiment de la bateria a la part posterior de la unitat.
- Feu lliscar la tapa de la bateria.
- Insert two LR44 button batteries, ensuring correct polarity (+/-). The package includes 4 LR44 backup batteries.
- Tanqueu la tapa de la bateria amb seguretat.
- The device will automatically power on and begin displaying readings.
Figure 3: Battery installation and compartment details.
4. Instruccions de funcionament
The meter is designed for straightforward operation with no buttons for mode selection, ensuring continuous monitoring.
4.1 Lectura de la pantalla
- The large number on the display indicates the current humidity level in percentage (%).
- The smaller number on the display indicates the current temperature in Fahrenheit (℉).
Figure 4: Temperature display on the meter.
Figure 5: Humidity display on the meter.
4.2 Col·locació
Place the meter in the desired location. Ensure that the air vents on the device are not obstructed to allow for accurate air circulation and measurement. The meter is ideal for:
- Jars and containers
- Reptile tanks and terrariums
- Guitar cases
- Incubators and brooders
- Greenhouses and gardens
- Cellars, fridges, and closets
- Offices and other indoor spaces
Figure 6: Various application scenarios for the meter.
5. Especificacions
| Especificació | Valor |
|---|---|
| Tipus | Termòmetre digital higròmetre |
| Dimensions | 1.89" x 1.13" x 0.6" (48 mm x 28 mm x 15 mm) |
| Interval de mesura de temperatura | -58 ℉ a 158 ℉ |
| Precisió de la mesura de la temperatura | ±2 ℉ (a temperatura normal) |
| Interval de mesura de la humitat | 10% a 99% HR |
| Precisió de la mesura de la humitat | ±5% HR |
| Humitat Sampling Període | 10 segons |
| Tipus de bateria | 2 x LR44 button batteries |
| Durada de la bateria | 12-18 mesos |
| Mostra | LCD (No backlight function) |
| Material | ABS |
Figure 7: Material and display type of the meter.
6. Manteniment
To ensure the longevity and accuracy of your Veanic Mini Digital Temperature Humidity Meter, follow these simple maintenance guidelines:
- Neteja: Wipe the device clean with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the display or casing.
- Substitució de la bateria: When the display becomes dim or stops showing readings, it's time to replace the batteries. Refer to Section 3: Setup for battery replacement instructions.
- Emmagatzematge: Store the meter in a cool, dry place when not in use for extended periods.
7. Solució De Problemes
If you encounter any issues with your Veanic Mini Digital Temperature Humidity Meter, consider the following common solutions:
- Sense pantalla o pantalla atenuada: This usually indicates low battery power. Replace the LR44 batteries as described in the Setup section.
- Lectures inexactes:
- Ensure the air vents on the device are not blocked.
- Allow the device to acclimate to the environment for at least 15-30 minutes after placement or battery change.
- Avoid placing the meter in direct sunlight, near heat sources, or in areas with extreme drafts, as these can affect readings.
- If multiple meters are used, slight variations (within the accuracy tolerance) are normal.
- Display Shows 'EE' or 'HH': This may indicate that the temperature or humidity is outside the measurable range of the device. Move the meter to an environment within the specified operating ranges.
8. Garantia i Suport
Specific warranty information is not provided in the product details. For any product support, warranty claims, or further inquiries, please refer to the retailer where the product was purchased or visit the official Veanic brand store: