Danfoss 067L5955

Danfoss TR6 TXV Thermostatic Expansion Valve Kit

Model: 067L5955

For 1.5 to 3 ton Traditional HVAC Systems - A/C, Heat Pump, Bi Flow

1. Producte acabatview

The Danfoss TR6 thermostatic expansion valve is engineered for precise control of refrigerant flow in ducted split (residential) and light commercial air conditioning systems. Its hermetically sealed design and robust construction ensure long-term reliability and performance.

Danfoss TR6 TXV Thermostatic Expansion Valve Kit

Figure 1: The Danfoss TR6 TXV Thermostatic Expansion Valve Kit, showing its brass body, capillary tube, and sensing bulb.

Característiques principals:

Internal components of Danfoss TR6 TXV

Figura 2: Secció transversal view of the Danfoss TR6 TXV, highlighting internal components such as the hermetic power head, anti-hunt charge, robust stainless steel capillary tube, and built-in check valve.

2. Instal·lació i configuració

The Danfoss TR6 kit includes all necessary components for installation. Professional installation by a qualified HVAC technician is recommended to ensure proper function and system integrity.

Components inclosos:

Pautes generals d'instal·lació:

  1. Preparació del sistema: Ensure the HVAC system is depressurized and isolated before beginning installation.
  2. Connexió: Connect the valve to the evaporator using the appropriate fittings (aeroquip, chatleff, or flare) provided in the kit. Bimetal connections allow for soldering without excessive heat transfer.
  3. Bulb Placement: Securely attach the sensing bulb to the suction line using the provided bulb strap and insulating tape. Proper bulb placement is critical for accurate superheat control.
  4. Equalization Line: Connect the external equalization line (if applicable) to the suction line.
  5. Comprovació de fuites: After installation, perform a thorough leak check on all connections.
  6. System Evacuation and Charging: Evacuate the system to remove non-condensables and moisture, then charge with the correct refrigerant (R410A).
  7. Ajust de sobreescalfament: The valve features adjustable superheat. Adjustments should be made by a qualified technician according to system requirements.
Danfoss TR6 TXV dimensions

Figure 3: Technical drawing illustrating the dimensions of the Danfoss TR6 TXV in millimeters and inches.

System Integration Diagrams:

Traditional air conditioning system diagram

Figure 4: Diagram of a traditional air conditioning system (cooling only) showing the placement of the TR6 valve (A) controlling liquid injection in one direction.

Traditional air conditioning heat pump system diagram

Figure 5: Diagram of a traditional air conditioning / heat pump system with two TR6 valves (C and G), illustrating their function in cooling and heating modes with built-in check valves.

Simplified bi-flow air conditioning heat pump system diagram

Figure 6: Diagram of a simplified air conditioning / heat pump system (bi-flow) using a single TR6 valve (C) without an internal check valve, controlling liquid injection in both directions.

Danfoss TR6 TXV detailed dimensions

Figure 7: Detailed technical drawing of the Danfoss TR6 TXV, showing various dimensions and connection points.

Isomètric view of Danfoss TR6 TXV

Figure 8: Isometric view of the Danfoss TR6 TXV, providing a three-dimensional perspective of the valve and its components.

3. Principis de funcionament

The Danfoss TR6 thermostatic expansion valve regulates the flow of liquid refrigerant into the evaporator based on the superheat of the refrigerant vapor leaving the evaporator. The sensing bulb, attached to the suction line, monitors the refrigerant temperature. Changes in this temperature cause the charge within the bulb to expand or contract, which in turn opens or closes the valve orifice, maintaining optimal superheat and ensuring efficient system operation.

The balanced port design minimizes the influence of varying condensing pressures on the valve's operation, providing stable control. For heat pump applications, the built-in check valve allows refrigerant flow in one direction while preventing it in the opposite, ensuring proper operation during heating and cooling cycles.

4. Manteniment

The Danfoss TR6 TXV is designed for long-term, maintenance-free operation due to its robust and hermetically sealed construction. Regular maintenance of the overall HVAC system, including filter changes and coil cleaning, will contribute to the longevity and efficiency of the expansion valve.

5. Solució De Problemes

Troubleshooting issues related to the expansion valve typically involves diagnosing refrigerant flow problems or incorrect superheat. Always consult a qualified HVAC technician for diagnosis and repair.

Símptomes comuns i causes potencials:

For complex issues, it is recommended to use diagnostic tools such as pressure gauges and temperature probes to accurately assess system performance and identify the root cause.

6. Especificacions

EspecificacióValor
MarcaDanfoss
Número de model067L5955
MaterialAcer inoxidable, llautó
Dimensions de l'article (L x A x A)2.75 x 3.5 x 2.5 polzades
Pes de l'article1.45 lliures (0.53 kg)
Mida de la connexió d'entrada3/8 polzada
Tipus de connexió d'entradaOutside Diameter Flared (ODF)
Mida de connexió de presa3/8 polzada
Tipus de connexió de presaFlare
Pressió màxima de funcionament49 bar
Nombre de Ports2
Orifice Capacity3 TR (10.50 kW)
Refrigerants compatiblesR410A
Configuració de fàbrica10.22 bar / 133.5 psig
Temperature Range (MIN)-10 degC / 15 degF
Temperature Range (MAX)15 degC / 60 degF
Ajustable
Vàlvula de retencióSí (integrat)
Longitud del tub capil·lar800 mm / 31.5 polzades

7. Garantia i Suport

Warranty information for the Danfoss TR6 TXV Thermostatic Expansion Valve Kit is typically provided by the manufacturer, Danfoss, or the authorized seller at the time of purchase. Please refer to your purchase documentation or contact the seller for specific warranty terms and conditions.

For technical support, installation assistance, or further product information, please contact Danfoss directly or consult their official website. Danfoss also offers the Coolselector®2 app, an advanced calculation and selection software, which can assist in selecting appropriate Danfoss components for your HVAC system.

Documents relacionats - 067L5955

Preview Danfoss Universal TR 6 TXV: Eficiència energètica i substitució OEM per a sistemes de climatització
Exploreu la vàlvula d'expansió termostàtica (TXV) Danfoss Universal TR 6 per a aire condicionat residencial i bombes de calor. Les característiques inclouen millores significatives d'eficiència energètica, capacitats de substitució OEM i especificacions tècniques detallades per a sistemes R-22 i R-410A.
Preview Guia d'instal·lació de la vàlvula d'expansió termostàtica Danfoss TR6
Guia d'instal·lació de la vàlvula d'expansió termostàtica Danfoss TR6, que inclou refrigerants, pressió de treball, direcció del flux, configuració i especificacions tècniques.
Preview Guia d'instal·lació de la vàlvula d'expansió termostàtica Danfoss TR6
Guia d'instal·lació de la vàlvula d'expansió termostàtica Danfoss TR6, que cobreix la compatibilitat de refrigerants, la pressió de treball, la direcció del flux, la configuració i les especificacions tècniques.
Preview Dades tècniques i guia d'aplicació de la vàlvula d'expansió termostàtica Danfoss TR6
Guia completa de la vàlvula d'expansió termostàtica Danfoss TR6, que cobreix les seves característiques, aplicacions en sistemes HVAC/R, especificacions tècniques, dimensionament, informació de comanda i principis de disseny. Inclou diagrames i taules per a una fàcil consulta.
Preview Danfoss TGE Series Thermostatic Expansion Valves - Technical Data
Comprehensive technical data and specifications for Danfoss TGE series thermostatic expansion valves, including types TGE 10, TGE 20, and TGE 40. Covers applications, features, operating conditions, technical data, sizing, and ordering information for various refrigerants.
Preview Guia d'instal·lació de la vàlvula d'expansió termostàtica Danfoss TCBE/TCCE/TCAE
This installation guide provides detailed instructions for Danfoss TCBE, TCCE, and TCAE series thermostatic expansion valves. It covers general specifications like maximum working and test pressures, temperature limits, connection sizes, and essential installation steps including pressure testing and superheat adjustment. The guide also includes a table for superheat settings based on different refrigerants (R22/R407C, R134a, R404A/R507, R410A) and operating temperature ranges (N, NM, B).