Introducció
The Southwire 40012S Receptacle Tester is a compact and essential tool designed to quickly and accurately identify common wiring problems in standard 120V AC electrical outlets. This device helps ensure the safety and proper functioning of your electrical system by indicating correct wiring, open ground, open neutral, open hot, hot/ground reverse, and hot/neutral reverse conditions.
Its simple plug-and-read operation makes it suitable for both professionals and homeowners for routine checks and troubleshooting.
Informació de seguretat
Always observe the following safety precautions when using the receptacle tester:
- No utilitzeu el provador si sembla danyat.
- Ensure your hands are dry before handling the tester or any electrical outlet.
- Do not attempt to open or modify the tester. There are no user-serviceable parts inside.
- This tester is designed for 120V AC outlets only. Do not use it on higher voltage circuits.
- Always follow local electrical codes and safety regulations.
- If a wiring fault is detected, consult a qualified electrician for repair. Do not attempt to fix wiring issues yourself unless you are a qualified professional.
Producte acabatview
The Southwire 40012S Receptacle Tester features a durable design with clear indicator lights for easy fault identification.

Figura 1: Frontal view of the Southwire 40012S Receptacle Tester, highlighting its compact design and the clear labeling for voltage and fault indications.
Característiques principals:
- Fault Indicator Lights: Three distinct lights illuminate in various patterns to indicate specific wiring conditions.
- Wire Legends: A printed legend on the tester clearly explains what each light pattern signifies.
- Reinforced Prongs: Designed for durability and reliable connection to outlets.
- Disseny compacte: Small and lightweight for easy portability and storage.

Figure 2: Diagram detailing the features and functions of the receptacle tester, showing its internal components and operational capabilities.
Configuració i funcionament
Using the Southwire 40012S Receptacle Tester is straightforward. No setup is required beyond simply plugging it into the outlet you wish to test.
Instruccions de funcionament:
- Insert the Tester: Firmly plug the Southwire 40012S Receptacle Tester into the 120V AC outlet you intend to test. Ensure it is fully seated in the receptacle.
- Observe the Lights: Once plugged in, the tester's indicator lights will illuminate in a specific pattern. Refer to the legend printed on the tester's label to interpret the results.
- Interpretar els resultats:
- Two Amber Lights (Left and Right): Indica CORRECTE cablejat.
- Middle Amber Light Only: Indica TERRA OBERTA.
- Right Amber Light Only: Indica OBERT NEUTRE.
- Left Amber Light Only: Indica OBRIR CALOR.
- Left Amber and Middle Red Lights: Indica HOT/GRD REV (Hot and Ground Reversed).
- Middle Amber and Right Red Lights: Indica HOT/NEU REV (Hot and Neutral Reversed).
- Remove the Tester: Once you have noted the results, carefully unplug the tester from the outlet.

Figure 3: The receptacle tester being prepared for use, showing its compact size and how it fits into a standard outlet.

Figure 4: The receptacle tester actively checking an outlet, with its lights indicating the wiring status.
Manteniment
The Southwire 40012S Receptacle Tester requires minimal maintenance to ensure its longevity and accurate performance.
- Neteja: Wipe the tester with a dry, soft cloth to remove dust or dirt. Do not use abrasive cleaners or solvents.
- Emmagatzematge: Store the tester in a cool, dry place, away from direct sunlight and extreme temperatures.
- Inspecció: Before each use, visually inspect the tester for any signs of damage, such as cracks in the casinpues doblegades o doblegades. No l'utilitzeu si està malmès.
Resolució de problemes
If the Southwire 40012S Receptacle Tester does not function as expected, consider the following:
- No Lights Illuminate:
- Assegureu-vos que el provador estigui completament inserit a la presa de corrent.
- Check if the outlet has power (e.g., by plugging in a lamp). If there is no power, the circuit breaker may be tripped or there is a complete open circuit.
- Inspect the tester for visible damage. If damaged, discontinue use.
- Lectures incorrectes:
- Ensure you are correctly interpreting the light patterns according to the legend on the tester.
- Test the tester on a known good outlet to verify its functionality.
If troubleshooting steps do not resolve the issue, or if a wiring fault is indicated, it is recommended to contact a qualified electrician for further assistance.
Especificacions
| Especificació | Detall |
|---|---|
| Número de model | 40012S |
| Marca | Southwire |
| Dimensions del producte | 2.54 x 4.32 x 9.14 cm (0.99 x 1.70 x 3.59 polzades) |
| Pes de l'article | 54.43 g (0.12 lliures) |
| Font d'alimentació | Elèctric amb cable |
| Tipus de mesura | Voltmeter (for wiring status indication) |
| Color | Negre |
| UPC | 032886699832 |

Figure 5: Visual representation of the tester's dimensions and weight.
Garantia i Suport
For information regarding warranty coverage, technical support, or service for your Southwire 40012S Receptacle Tester, please refer to the official Southwire weblloc web o contacteu directament amb el seu departament d'atenció al client.
Contact details can typically be found on the manufacturer's packaging or their official website. Please have your model number (40012S) ready when contacting support.