Red Lion RL-SPRK200

Red Lion RL-SPRK200 Sprinkler/Irrigation Pump Instruction Manual

Model: RL-SPRK200 (97102001)

Introducció

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Red Lion RL-SPRK200 Sprinkler/Irrigation Pump. The RL-SPRK200 is a 2 HP, 230 Volt pump designed for both residential and commercial lawn and turf sprinkling systems. It features a rugged cast iron casing and a high-efficiency thermoplastic impeller and diffuser.

The pump is engineered for easy priming up to 25 feet, requiring no additional priming after the initial fill. It delivers up to 76 GPM at 10 PSI and 64 GPM at 30 PSI, capable of handling up to 21 sprinkler heads with 1/2-inch fittings or 10 sprinkler heads with 3/4-inch fittings in each zone.

Red Lion RL-SPRK200 pump with its thermoplastic impeller shown separately

Image: The Red Lion RL-SPRK200 pump with its thermoplastic impeller, highlighting the internal component.

Informació de seguretat

Instruccions importants de seguretat: Read all instructions carefully before installation and operation. Failure to follow these instructions can result in serious injury or property damage.

  • Risc elèctric: This pump operates on 230 Volts only. It is not designed for 115 Volts and does not come with a power cord. The pump must be wired into a 230 Volt power source by a qualified electrician in accordance with all local electrical codes. Ensure the power supply is disconnected before performing any installation or maintenance.
  • Posada a terra: Always ensure the pump is properly grounded to prevent electrical shock.
  • Parts mòbils: Mantingueu les mans i la roba allunyades de les parts mòbils durant el funcionament.
  • Superfícies calentes: The pump motor can become hot during operation. Avoid contact to prevent burns.
  • Pressió de l'aigua: Always relieve system pressure before servicing the pump or plumbing.
  • Advertència de la proposta 65: Aquest producte pot contenir productes químics coneguts a l’Estat de Califòrnia per causar càncer i defectes congènits o altres danys reproductius.

Contingut del paquet

Verifiqueu que tots els components siguin presents en desembalar-lo:

  • Red Lion RL-SPRK200 Sprinkler/Irrigation Pump with Thermoplastic Impeller
  • Manual d'instal·lació (aquest document)

Configuració

Proper setup is crucial for optimal performance and longevity of your pump.

1. Col·locació

  • Install the pump on a firm, level surface to minimize vibration and ensure stable operation.
  • Locate the pump in a dry, well-ventilated area, protected from freezing temperatures and direct exposure to the elements.
  • Ensure adequate space around the pump for ventilation and future maintenance.

2. Connexions de fontaneria

The pump features a 2-inch Female NPT threaded intake and a 1.5-inch Female NPT threaded discharge.

  • Use appropriate pipe fittings and thread sealant to ensure watertight connections.
  • Install a foot valve or check valve on the intake line to maintain prime.
  • Ensure all plumbing is adequately supported to prevent strain on the pump housing.
Diagram showing the Red Lion RL-SPRK200 pump with labels for 2 inch FNPT intake, 1.5 inch FNPT discharge, capacitor start, thermally protected motor, and cast iron casing.

Image: Key features of the RL-SPRK200 pump, including intake and discharge ports.

3. Connexió elèctrica

This pump requires a dedicated 230 Volt power source.

  • Electrical wiring must be performed by a qualified electrician.
  • Connect the pump to a 230 Volt, 10.9 running Ampcircuit s.
  • The motor is a Capacitor-run PSC design and is thermally protected.
  • Assegureu-vos que tot el cablejat compleixi amb els codis elèctrics nacionals i locals.

4. Aclarint la bomba

The RL-SPRK200 is designed for one-time priming. No additional priming is required after the initial fill, provided the intake line and foot valve hold prime.

  1. Remove the priming plug located on the top of the pump casing.
  2. Ompliu la bomba casing completely with water until it overflows from the priming hole.
  3. Torneu a col·locar el tap d'encès de manera segura.
  4. Open any discharge valves to allow air to escape the system.
  5. Turn on the power to the pump. The pump should begin to draw water and build pressure.
  6. Allow the pump to run until a steady stream of water flows from the discharge.
  7. If the pump does not prime within 5 minutes, turn it off, recheck all connections for leaks, and repeat the priming process.
Red Lion RL-SPRK200 pump operating in a lawn with sprinklers in the background.

Image: The RL-SPRK200 pump installed and operating, providing water for a sprinkler system.

Instruccions de funcionament

Once the pump is properly installed and primed, operation is straightforward.

  • Ensure all intake and discharge valves are open before starting the pump.
  • Turn on the electrical power to the pump. The pump will start and begin to build pressure.
  • Monitor the system for proper water flow and pressure. The pump can deliver up to 76 GPM at 10 PSI and 64 GPM at 30 PSI.
  • If the pump runs continuously without building pressure, refer to the troubleshooting section.
  • To stop the pump, turn off the electrical power.
Close-up of a sprinkler head watering a lawn, with the Red Lion pump visible in the foreground.

Image: A sprinkler head in operation, demonstrating the pump's function in an irrigation system.

Manteniment

Regular maintenance ensures reliable performance and extends the life of your pump.

  • Inspecció periòdica: Periodically inspect the pump and plumbing for leaks, corrosion, or damage. Tighten any loose connections.
  • Neteja: Keep the pump area clean and free of debris to ensure proper motor ventilation.
  • Hivernització: In areas subject to freezing temperatures, the pump must be drained completely to prevent damage. Disconnect power, remove drain plugs, and allow all water to escape. Store the pump in a warm, dry location if possible.
  • Impeller Check: If performance degrades, inspect the thermoplastic impeller for wear or obstructions.

Resolució de problemes

This section addresses common issues you might encounter with your Red Lion RL-SPRK200 pump.

ProblemaCausa possibleSolució
La bomba no arrencaNo power; tripped circuit breaker; faulty wiring.Check power supply; reset breaker; verify 230V connection.
La bomba funciona però no hi ha aigua o el cabal és baixLoss of prime; air leak in suction line; clogged intake; low water source.Re-prime the pump; check all suction line connections for leaks; clear intake; ensure adequate water supply.
Pump not performing to specificationsVol incorrectetage (e.g., connected to 115V); worn impeller; motor issue.Ensure pump is connected to a 230 Volt power source. Inspect impeller; contact support if motor issue is suspected.
Excés de soroll o vibracióLoose mounting; cavitation (air in pump); foreign object in impeller.Tighten mounting bolts; check for air leaks in suction line; inspect impeller for obstructions.

For more detailed troubleshooting, consult the full owner's manual or contact technical support.

Especificacions

Technical specifications for the Red Lion RL-SPRK200 Sprinkler/Irrigation Pump:

  • Model: RL-SPRK200 (97102001)
  • Potència (HP): 2.0 CV
  • Voltage: 230 Volts
  • Córrer Amps: 10.9 Amps @ 230 V
  • Wattage: 7332 watts
  • Cabal màxim: 76 galons per minut (GPM)
  • Pressió màxima: 49 PSI
  • Maximum Lifting Height (Suction Lift): 25 peus
  • Intake Connection: 2-inch Female NPT threaded
  • Connexió de descàrrega: 1.5-inch Female NPT threaded
  • Material: Cast Iron casing, Thermoplastic impeller
  • Dimensions del producte (L x A x A): 21.85" x 11.42" x 10.2"
  • Pes de l'article: 63 lliures
  • Tipus de motor: Capacitor-run PSC design, Thermally protected
  • Certificacions: CSA listed (US and Canada)
Technical diagram showing the dimensions of the SPRK series sprinkler pumps, with height A at 10.2 inches, length B at 21.85 inches, and width C at 11.42 inches.

Image: Dimensional drawing of the SPRK series pumps, including the RL-SPRK200.

Performance chart for Centrifugal Sprinkler Pumps, showing Total Dynamic Head (ft) versus Capacity (US gpm) for various RL-SPRK models, including RL-SPRK200.

Image: Performance curve chart illustrating the flow and head characteristics of the RL-SPRK200 and other models.

Garantia

The Red Lion RL-SPRK200 Sprinkler/Irrigation Pump is covered by a Garantia del fabricant de 2 anys. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the warranty documentation included with your product or contact Red Lion customer support.

Suport

For technical assistance, troubleshooting, or installation support, please contact Red Lion customer service.

  • Telèfon d'assistència tècnica: 1-888-885-9254
  • You may also visit the official Red Lion weblloc per a recursos addicionals i preguntes freqüents.
Red Lion 'About Us' image featuring people and the brand logo, with technical support contact information.

Image: Red Lion 'About Us' section, including technical support contact details.

Documents relacionats - RL-SPRK200

Preview Red Lion RL-SPRK Series Sprinkler Pump Owner's Manual - Installation, Operation, Maintenance Guide
This manual provides comprehensive instructions for the Red Lion RL-SPRK Series Sprinkler Pumps, covering installation, voltage settings, operation, maintenance, troubleshooting, and replacement parts. Designed for residential and commercial lawn and turf sprinkler systems.
Preview Red Lion RLHE-300 Cast Iron Industrial Sprinkler Pump Owner's Manual
Comprehensive owner's manual for the Red Lion RLHE-300 industrial sprinkler pump, covering installation, operation, maintenance, and troubleshooting. Features include heavy-duty iron casing, high-efficiency impeller, and automatic thermal protector.
Preview Red Lion 4-inch Deep Well Submersible Pump Manual
Comprehensive guide for Red Lion 4-inch deep well submersible pumps, covering installation, electrical connections, maintenance, and troubleshooting for RL and RS series models.
Preview Red Lion Pump Troubleshooting Guide: Solutions for Jet, Submersible, and Transfer Pumps
Comprehensive troubleshooting guide for Red Lion water pumps, including Shallow Well Jet Pumps (e.g., RJS-50-PREM), Convertible Jet Pumps (e.g., RJC-50), 4" Submersible Well Pumps (e.g., RL12G10-3W2V), Submersible Utility & Sump Pumps, RL-S Cast Iron Surface Effluent Pumps, RL-50 Transfer Pumps, and RLSP/RLHE Sprinkler Pumps. Find solutions for common issues like motor failure, priming problems, low pressure, and more.
Preview Red Lion RJSE-75SS Sprinkler Utility Pump - Operation and Maintenance Manual
Comprehensive guide for the Red Lion RJSE-75SS Sprinkler Utility Pump, covering safety warnings, electrical precautions, application, installation, operation, maintenance, and troubleshooting. Includes detailed diagrams and warranty information.
Preview Red Lion 4-Inch Deep Well Submersible Pump Owner's Manual & Installation Guide
Comprehensive guide for Red Lion 4-inch deep well submersible pumps (RL-series and RS-series), covering specifications, safety, installation, maintenance, and troubleshooting for rural water supply. Includes model details, electrical requirements, and operational advice.