Introducció
The FLIR VT8-600 is a high-quality voltage, continuity, and current tester, ideal for electricians and service technicians who troubleshoot and verify electrical installations or systems within light commercial and industrial facilities. The optimized open-jaw design of the VT8-600 allows it to access tight spaces and reliably measure large-diameter cables. Comprehensive measurement features make the FLIR VT8-600 a versatile tool – one meter can get the job done. Carry the compact tester in your pocket to be ready at any moment for easy troubleshooting and repair. It features a CAT III-600V/CAT IV-300V safety rating and a measurement range of 100A/600V.
Configuració
1. Instal·lació de la bateria
The FLIR VT8-600 requires 2 AA batteries for operation, which are included with the device. To install or replace batteries:
- Localitzeu la tapa del compartiment de la bateria a la part posterior de la unitat.
- Use a suitable tool (e.g., a small screwdriver) to open the battery compartment.
- Introduïu les 2 piles AA, assegurant-vos de la polaritat correcta (+/-) tal com s'indica a l'interior del compartiment.
- Tanqueu de manera segura la tapa del compartiment de la bateria.
2. Connexió dels cables de prova
Per a mesures que requereixen cables de prova (per exemple, voltage, resistance, continuity, capacitance), connect the leads to the appropriate input jacks on the bottom of the device.
- Inseriu el cable de prova negre al connector 'COM' (comú).
- Insert the red test lead into the 'VΩ' jack for voltage, mesures de resistència, continuïtat i capacitància.

Imatge: Part posterior view of the FLIR VT8-600 showing the battery compartment and test lead connections. The black lead is connected to the 'COM' port and the red lead to the 'VΩ' port.
Instruccions de funcionament
The FLIR VT8-600 features a rotary dial for mode selection and dedicated buttons for additional functions.
1. Engegada/Apagada i Selecció de Mode
Turn the rotary dial to the desired measurement function to power on the device. Turn the dial to 'OFF' to power off the device.
2. Funcions de mesura
- Volum AC / DCtagMesura de e (V∼ / V—)
Seleccioneu el voltage mode on the rotary dial. Connect the test leads in parallel to the circuit or component to measure voltage. The device supports up to 600V. - AC/DC Current Measurement (A∼ / A—)
Select the current mode on the rotary dial. Use the open jaw to clamp around a single conductor to measure current. The device supports up to 100A. Ensure the conductor is centered within the jaw for accurate readings.
Image: The FLIR VT8-600 being used to measure current by clamping its open jaw around a wire inside an electrical panel.

Image: A close-up of the FLIR VT8-600 measuring current with its open jaw around a thick black cable within an electrical distribution box.
- Resistance Measurement (Ω)
Select the resistance mode. Connect the test leads across the component when it is de-energized. - Continuity Test (⚡)
Select the continuity mode. Place the test leads across the circuit or component. A continuous tone indicates continuity. - Capacitance Measurement (‡)
Select the capacitance mode. Connect the test leads across the capacitor. Ensure the capacitor is discharged before testing.
3. Funcions especials
- Botó MODE: Toggles between AC and DC measurements or other sub-functions within a mode.
- REL/ZERO Button: Used for relative measurements or to zero out the display for current measurements.
- Botó HOLD: Freezes the current reading on the display. Press again to release.
- Backlight/Work Light Button: Activates the display backlight and the integrated LED work light for improved visibility in dimly lit environments.

Image: The FLIR VT8-600 held by a gloved hand, with red and black test leads inserted into an electrical panel to measure voltage.

Image: The FLIR VT8-600 showing a voltage reading on its backlit display, with test leads connected and positioned near an electrical panel.
Manteniment
Neteja
To ensure optimal performance and longevity of your FLIR VT8-600, follow these cleaning guidelines:
- Wipe the exterior of the device with a clean, damp tela. No utilitzeu netejadors abrasius ni dissolvents.
- Ensure the device is powered off and disconnected from any electrical circuits before cleaning.
- Keep the display clean and free from dust or smudges for clear readings.
Canvi de bateria
Replace batteries when the low battery indicator appears on the display. Refer to the 'Battery Installation' section under Setup for detailed instructions.
Emmagatzematge
When not in use, store the FLIR VT8-600 in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.
Resolució de problemes
If you encounter issues with your FLIR VT8-600, refer to the following common problems and solutions:
| Problema | Causa possible | Solució |
|---|---|---|
| El dispositiu no s'encén. | Piles gastades o instal·lades incorrectament. | Comproveu la polaritat de la bateria o substituïu les bateries. |
| Lectures inexactes. | Incorrect mode selected; poor test lead connection; external interference. | Ensure correct mode is selected. Re-seat test leads. Move away from strong electromagnetic fields. |
| Sense to de continuïtat. | Open circuit; faulty test leads. | Verify the circuit is closed. Check test leads for damage or replace them. |
| La pantalla està tènue o parpelleja. | Bateria baixa. | Substituïu les piles. |
If the problem persists after attempting these solutions, please contact FLIR customer support.
Especificacions
| Característica | Detall |
|---|---|
| Fabricant | FLIR |
| Número de part | VT8-600 |
| Pes de l'article | 163 g |
| Dimensions del producte | 5.3 x 3.5 x 21 cm |
| Bateries | Necessites 2 piles AA (incloses) |
| Número de model de l'article | VT8-600 |
| Color | Negre |
| Estil | 100 Amp / 600 Volt |
| Tipus de font d'alimentació | Elèctric amb cable |
| Number of Item Subunits | 1 |
| Sistema de mesura | mètrica |
| Precisió de la mesura | +/-0.5% |
| Especificacions compatibles | CAT III-600V / CAT IV-300V |
| Components inclosos | VT8-600, Silicone Test Leads, Carry Case, 2 x AA Alkaline Batteries |
| Tipus de pila de bateria | Alcalí |
| Data de primera disponibilitat | 14 de setembre de 2023 |
| Classificació de temperatura superior | 50 ℃ |
| Tipus de mesura | Voltmeter, Ammeter, Ohmmeter |
| UPC | 793950386002 |
Informació de la garantia
The FLIR VT8-600 comes with a Garantia limitada d'3 any. This warranty covers defects in materials and workmanship under normal use. For specific terms and conditions, please refer to the warranty card included with your product or visit the official FLIR weblloc.
Atenció al client
For technical assistance, product inquiries, or warranty claims, please contact FLIR customer support through their official channels:
- Weblloc: Visit the official FLIR weblloc web amb recursos de suport, preguntes freqüents i formularis de contacte.
- Telèfon: Refer to the contact information provided in your product packaging or on the FLIR weblloc web per a números de suport regional.
When contacting support, please have your product model (VT8-600) and serial number (if applicable) ready.