IHP 60J79

IHP OEM Lennox Gas Fireplace Thermopile (60J79) User Manual

Model: 60J79 | Brand: IHP

1. Introducció

This user manual provides essential information regarding the IHP OEM Lennox Gas Fireplace Thermopile, model 60J79. This genuine OEM part is designed for use in various Lennox and IHP gas stoves, fireplaces, and inserts. Understanding its function, proper installation, and maintenance will ensure the safe and efficient operation of your heating appliance.

2. Producte acabatview

IHP OEM Lennox Gas Fireplace Thermopile (60J79)

Image of the IHP OEM Lennox Gas Fireplace Thermopile (60J79).

The thermopile is a critical safety and operational component in many gas fireplaces and heating systems. It is essentially a thermoelectric device that converts heat from the pilot flame into a small electrical current (millivolts). This current is then used to energize the gas valve, allowing the main burner to ignite and operate. If the pilot flame extinguishes, the thermopile stops producing current, which in turn closes the gas valve, preventing unburnt gas from accumulating.

The IHP OEM Lennox Gas Fireplace Thermopile (60J79) is a genuine, certified OEM part from Innovative Hearth Products (IHP), ensuring compatibility and reliable performance with specified Lennox and IHP models.

Detailed text description of the image: This image displays the IHP OEM Lennox Gas Fireplace Thermopile (60J79), a crucial component for gas fireplaces. It features a metallic rod-like sensor connected to a coiled wire, designed to generate a small electrical current when heated by the pilot flame. The sensor tip appears dark, indicating its heat-resistant material, while the connection points are brass-colored. The coiled wire is sheathed in a protective metallic casing.

3. Compatibilitat

This thermopile (part number 60J79) is a direct replacement for the following Lennox / IHP Gas Models. Please verify your appliance's model number before purchasing i instal·lant.

Xemeneies de gas Elite:

Xemeneies de gas Merit:

4. Instal·lació i substitució

ADVERTIMENT: Installation should only be performed by a qualified service technician. Improper installation can lead to gas leaks, fire, or carbon monoxide poisoning. Always turn off the gas supply and disconnect power to the appliance before beginning any work.

  1. La seguretat primer: Ensure the gas supply to the fireplace is turned off at the main shut-off valve. Disconnect electrical power to the unit if applicable. Allow the fireplace to cool completely.
  2. Access the Thermopile: Locate the existing thermopile within your fireplace. It is typically positioned near the pilot light assembly, where it can be directly heated by the pilot flame. You may need to remove decorative logs, grates, or access panels.
  3. Disconnect Old Thermopile: Carefully disconnect the thermopile's lead wires from the gas valve or control board. Note the routing of the wire and how it is secured. The thermopile itself is usually threaded into a bracket or the pilot assembly. Use a wrench to unscrew it.
  4. Install New Thermopile: Thread the new IHP OEM Lennox Thermopile (60J79) into the same location. Do not overtighten. Ensure the tip of the thermopile will be fully enveloped by the pilot flame when lit.
  5. Connecteu els cables: Connect the lead wires of the new thermopile to the appropriate terminals on the gas valve or control board. Refer to your fireplace's specific service manual for correct wiring diagrams. Ensure connections are secure.
  6. Torneu a muntar: Replace any removed panels, grates, or logs.
  7. Prova de funcionament: Slowly turn the gas supply back on. Follow your fireplace's instructions to light the pilot. Once the pilot is stable, test the main burner ignition. Observe the pilot flame's interaction with the thermopile tip. The pilot flame should fully engulf the thermopile tip for proper operation.
  8. Comproveu si hi ha fuites: After restoring gas, perform a leak test around all connections using a gas leak detection solution (soapy water). Bubbles indicate a leak. If a leak is detected, turn off the gas immediately and rectify the connection before retesting.

5. Operation (Function)

The thermopile operates passively, converting thermal energy from the pilot flame into electrical energy. When the pilot flame heats the thermopile's tip, it generates a small voltage (typically 250-750 millivolts). This voltage is sent to the gas valve, which then allows the main burner to ignite when called for by the thermostat or control switch. If the pilot flame goes out, the thermopile cools down, stops producing voltage, and the gas valve automatically closes, shutting off the gas supply to both the pilot and main burner. This safety mechanism prevents uncombusted gas from accumulating, which could lead to a hazardous situation.

6. Manteniment

Regular maintenance of your fireplace system, including the thermopile, can extend its lifespan and ensure safe operation. While the thermopile itself requires minimal direct maintenance, consider the following:

7. Solució De Problemes

If your gas fireplace is experiencing issues related to ignition or staying lit, a faulty thermopile could be the cause. Here are common symptoms and troubleshooting steps:

Common Symptoms of a Faulty Thermopile:

Passos de resolució de problemes:

  1. Verify Pilot Flame: Ensure the pilot flame is strong, blue, and consistently hitting the thermopile tip. Adjust the pilot flame if necessary (refer to your fireplace manual).
  2. Clean Pilot Assembly: Turn off gas and power. Carefully clean any debris from the pilot orifice and thermopile tip.
  3. Comproveu les connexions: Ensure all thermopile connections to the gas valve are clean and tight. Loose or corroded connections can prevent proper voltage transmissió.
  4. Test Thermopile Output (Advanced): With a multimeter set to DC millivolts, connect the leads to the thermopile terminals on the gas valve (or directly to the thermopile leads if accessible and safe). Light the pilot. A healthy thermopile should generate at least 250-350 millivolts (mV) when heated by the pilot flame. If the reading is significantly lower or zero, the thermopile is likely faulty and needs replacement.
  5. Consulteu un professional: If troubleshooting steps do not resolve the issue, or if you are uncomfortable performing these checks, contact a qualified HVAC technician or fireplace service professional.

8. Especificacions

Tipus de partTermopila
Número de model60J79
MarcaIHP (Innovative Hearth Products) OEM
CompatibilitatLennox / IHP Gas Fireplaces, Stoves, and Inserts (refer to Section 3 for full list)
Pes de l'articleAproximadament 1 lliura (0.45 kg)
Piles necessàriesNo
ASINB07JZVR1BW

9. Garantia i Suport

Specific warranty details for the IHP OEM Lennox Gas Fireplace Thermopile (60J79) are not provided within the product information. For warranty inquiries, please refer to the documentation included with your purchase or contact the original seller or Innovative Hearth Products (IHP) directly.

For technical support or further assistance with installation and troubleshooting, it is recommended to consult a qualified HVAC technician or fireplace service professional. You may also contact IHP customer service for official support channels.

Documents relacionats - 60J79

Preview Fireplace Blower Kits FBK-100 & FBK-200 Installation Guide
Installation instructions for FireplaceBlowersOnline FBK-100 and FBK-200 blower accessory kits, compatible with numerous Innovative Hearth Products (IHP) fireplace models. Includes safety warnings, step-by-step procedures, and wiring diagrams.
Preview Innovative Hearth Products PC-DVF32TMHSTPN Conversion Kit Installation Guide
Detailed installation instructions for the Innovative Hearth Products PC-DVF32TMHSTPN conversion kit, enabling the conversion of DVF32TMHST and DVF32TMH PN series vented decorative fireplaces from natural gas to propane/LP gas. Includes parts, tools, step-by-step procedures, and safety warnings.
Preview Manual del propietari i guia d'instal·lació de les xemeneies superiors DRI3030TEN i DRI2530TEN
Aquest manual d'usuari i guia d'instal·lació complets proporcionen detalls essencials per a les xemeneies de gas de ventilació directa Superior Fireplaces DRI3030TEN i DRI2530TEN, que abasten la instal·lació, el funcionament, la seguretat i el manteniment.
Preview Innovative Hearth Products RC-S-TOUCH Remote Control Installation and Operation Manual
Comprehensive guide for installing and operating the Innovative Hearth Products RC-S-TOUCH remote control system for gas heating appliances, covering setup, functions, programming, and troubleshooting.
Preview Guia d'instal·lació dels kits de pantalla rígida per a xemeneies Innovative Hearth Products
Instruccions d'instal·lació pas a pas per als kits de pantalla rígida per a xemeneies d'Innovative Hearth Products, que detallen la compatibilitat amb diversos models de xemeneies i les precaucions de seguretat essencials. Inclou el contingut del kit, informació general i notes d'ús importants.
Preview Innovative Hearth Products 36" Electric Fireplace Installation and Operation Manual
Comprehensive installation and operation instructions for Innovative Hearth Products (IHP) 36" Electric Fireplaces, including safety warnings, specifications, installation steps, maintenance, troubleshooting, and warranty information.