SMART SENSOR AS8909

Portable H2 Gas Detector User Manual

Model: AS8909

Marca: SENSOR INTEL·LIGENT

1. Introducció

This user manual provides essential information for the safe and effective operation of your SMART SENSOR AS8909 Portable H2 Gas Detector. This device is designed for accurately detecting hydrogen gas (H2) concentrations in various environments, ensuring safety by alerting users to potentially hazardous levels.

Please read this manual thoroughly before using the device and keep it for future reference.

2. Informació de seguretat

ADVERTÈNCIA: Si no es segueixen aquestes instruccions de seguretat, es poden produir lesions greus o la mort.

  • Always operate the device in accordance with the instructions provided in this manual.
  • No intenteu modificar ni reparar el dispositiu. Envieu totes les tasques de manteniment a personal qualificat.
  • Ensure the device is regularly calibrated to maintain accuracy. Inaccurate readings can lead to dangerous situations.
  • This device is designed to detect hydrogen gas. It may not detect other hazardous gases.
  • The device is certified with GB3836 series anti-explosion standard, ensuring its safe operation in potentially explosive atmospheres. However, always exercise extreme caution in such environments.
  • Keep the device away from strong electromagnetic fields, extreme temperatures, and corrosive substances.

3. Producte acabatview

The SMART SENSOR AS8909 is a compact and portable hydrogen gas detector featuring a high-sensitivity electrochemical sensor and a clear LCD display.

3.1. Components del dispositiu

Davant view of the SMART SENSOR AS8909 Portable H2 Gas Detector

Figura 3.1: Frontal view of the AS8909 H2 Gas Detector.

Labeled diagram of the AS8909 H2 Gas Detector components

Figure 3.2: Labeled diagram showing key components including the high sensitive sensor, sampling pump connecting port, high density LCD screen with backlight, down button, up button, sound alarm, light alarm, confirm button, power on/off button, and battery charging port.

  • High Sensitive Sensor: Located at the top, responsible for detecting H2 gas.
  • Sampling Pump Connecting Port: For attaching an external sampling pump if needed.
  • High Density LCD Screen: Displays H2 concentration, battery status, and other information. Features a backlight for visibility in dark conditions.
  • Botons de control: Includes Up, Down, Confirm, and Power On/Off buttons for navigation and settings adjustment.
  • Indicadors d'alarma: Integrated sound alarm, light alarm, and vibration alarm to alert users to gas presence.
  • Port de càrrega de la bateria: Located at the bottom for recharging the built-in Li-battery.

3.2. Dimensions i portabilitat

Dimensions of the AS8909 H2 Gas Detector

Figure 3.3: The AS8909 detector measures approximately 120.2mm (height) x 64.5mm (width) x 38.3mm (depth), making it compact and easy to carry.

AS8909 H2 Gas Detector held in hand, demonstrating its portable design

Figure 3.4: The compact design and unique clip allow for convenient portability, fitting comfortably in hand.

3.3. Alarm Features

Diagram illustrating the sound, light, and vibration alarms of the AS8909 H2 Gas Detector

Figure 3.5: The device features three distinct alarm types: audible (sound alarm), visual (light alarm), and tactile (vibration alarm). It differentiates between low and high alarm values with varying frequencies of alarming noise.

3.4. Característiques clau

Close-up images highlighting key features of the AS8909 H2 Gas Detector: soft buttons, imported electrochemical sensor, rechargeable Li-battery, and big LCD screen display.

Figura 3.6: Detallada views of the soft, comfortable buttons, the imported electrochemical sensor for accurate detection, the integrated rechargeable Li-battery, and the large, clear LCD screen.

3.5. Llista d'embalatge

Contents of the AS8909 H2 Gas Detector package, including the gas monitor, paper gift box, user manual, CNEX certificate, calibration certificate, warranty card, and battery charger with cable.

Figure 3.7: The standard package includes the H2 gas monitor, user manual, charging adaptor, USB cable, hand carry case, calibration certificate, CNEX certificate, and a gift paper box.

3.6. Vídeo de desempaquetatge del producte

Video 3.1: This video demonstrates the unboxing and contents of the AS8909 H2 Gas Detector package, showing the device and its accessories.

4. Configuració

4.1. Càrrega inicial

  1. Connect the provided USB cable to the charging adaptor.
  2. Plug the charging adaptor into a standard power outlet.
  3. Connect the USB cable to the battery charging port at the bottom of the detector.
  4. Allow the device to charge fully before first use. The battery indicator on the LCD screen will show charging status. A full charge typically provides 10-12 hours of continuous operation.

4.2. Engegar per primera vegada

  1. Press and hold the Power On/Off button until the LCD screen illuminates.
  2. The device will perform a self-test and warm-up sequence. During this time, avoid exposing it to gas.
  3. Once the self-test is complete, the display will show '0 PPM' or the current ambient H2 concentration, indicating it is ready for use.

5. Instruccions de funcionament

5.1. Encendre/apagar

  • Per encendre: Press and hold the Power On/Off button for approximately 3 seconds until the screen lights up.
  • Per apagar: Press and hold the Power On/Off button for approximately 3 seconds. The screen will display a countdown or a power-off message before shutting down.

5.2. Prendre Mides

  • Once powered on and warmed up, the device continuously monitors the H2 gas concentration in its immediate environment.
  • The real-time H2 concentration (in PPM) is displayed prominently on the LCD screen.
  • For specific areas, hold the detector steadily in the desired location. If using a sampling pump, ensure it is correctly attached and functioning.

5.3. Alarm Settings and Response

The AS8909 features adjustable high and low alarm values. Factory preset low alarm value is 50ppm, and high alarm value is 100ppm.

  1. Adjusting Alarm Values: Refer to the detailed instructions in the full user manual (provided in the package) for navigating the menu using the Up, Down, and Confirm buttons to set custom alarm thresholds.
  2. Activació d'alarma: When the detected H2 concentration reaches or exceeds the preset low or high alarm values, the device will activate its alarms: audible sound (up to 80dB), flashing light, and vibration.
  3. Resposta a les alarmes: If an alarm sounds, immediately take appropriate safety measures, such as evacuating the area, ventilating the space, and identifying the source of the gas leak. Do not re-enter the area until the H2 concentration has returned to safe levels.

6. Manteniment

6.1. Neteja

  • Netegeu l'exterior del dispositiu amb un damp tela. No utilitzeu netejadors abrasius ni dissolvents.
  • Ensure no liquid enters the sensor opening or charging port.

6.2. Cura de la bateria

  • Recharge the battery when the low battery indicator appears on the LCD screen.
  • Avoid completely draining the battery frequently, as this can reduce its lifespan.
  • If storing the device for an extended period, charge the battery to approximately 50% and recharge every 3-6 months to prevent deep discharge.

6.3. Calibració

Regular calibration is crucial for maintaining the accuracy and reliability of your gas detector. It is recommended to have the device calibrated by a qualified professional at least once a year, or more frequently depending on usage and environmental conditions. Refer to the calibration certificate included in your package for details.

7. Solució De Problemes

ProblemaCausa possibleSolució
El dispositiu no s'encén.Bateria baixa o esgotada.Carregueu el dispositiu completament amb el carregador subministrat.
Inaccurate or fluctuating readings.Sensor contamination or damage; device needs calibration.Clean the sensor area carefully. Contact professional service for calibration or repair.
Alarm does not sound/light/vibrate.Alarm settings are off; speaker/LED/vibrator malfunction.Check alarm settings in the menu. If problem persists, contact support.
El dispositiu es bloqueja o deixa de respondre.Error de programari.Perform a soft reset by holding the power button until it shuts down, then restart. If unresponsive, allow battery to drain completely then recharge.

Si trobeu problemes que no figuren aquí o si les solucions suggerides no resolen el problema, poseu-vos en contacte amb l'atenció al client.

8. Especificacions

CaracterísticaEspecificació
MarcaSENSOR INTEL·LIGENT
ModelAS8909
Tipus de gasHydrogen gas (H2)
Gas Measurement Range0~1000 ppm
Resolució1 ppm
Principi de funcionamentSensor electroquímic
Tipus d’alarmaSound, Light, Vibration (adjustable values)
Nivell de so d'alarmaFins a 80 dB
Temperatura de funcionament-10~50°C
Humitat de funcionament15~95%RH (standard)
Temperatura d'emmagatzematge0~40°C
Font d'alimentació3.7V rechargeable Li-battery (Built-in)
Corrent de funcionament160 mA
Corrent de curtcircuit<3A
Nivell de proteccióIP65
Outer Enclosure MaterialPlàstic ABS
Pes net del producte200 g
Dimensions120.2 x 64.5 x 38.3 mm
UPC785197913837

9. Garantia i Suport

Your SMART SENSOR AS8909 Portable H2 Gas Detector comes with a standard manufacturer's warranty. Please refer to the warranty card included in your product package for specific terms and conditions, including the warranty period and coverage details.

For technical support, troubleshooting assistance, or warranty claims, please contact SMART SENSOR customer service. Contact information can typically be found on the product packaging, the official SMART SENSOR website, or the included warranty card.

It is recommended to register your product online (if applicable) to facilitate warranty service and receive important product updates.

Documents relacionats - AS8909

Preview SMART SENSOR AR8100 Oxygen Detector Instruction Manual
Instruction manual for the SMART SENSOR AR8100 portable oxygen detector. Learn how to operate, calibrate, and understand readings for accurate oxygen level measurement in various environments.
Preview SMART SENSOR AS823 Digital Lux Meter Instruction Manual
Instruction manual for the SMART SENSOR AS823 Digital Lux Meter, covering features, operations, specifications, and a detailed diagram description for accurate light measurement.
Preview AR824 Digital Sound Level Meter Operation Manual
Operation manual for the AR824 Digital Sound Level Meter by SMART SENSOR. Covers features, specifications, calibration, operation, and cautions for accurate sound measurement.
Preview Manual d'instruccions de l'anemòmetre SMART SENSOR AR816
Comprehensive instruction manual for the SMART SENSOR AR816 Anemometer, detailing its functions, operation, and technical specifications for wind speed and temperature measurement.
Preview Detectors i monitors de gas amb sensor intel·ligent - Catàleg de productes
Exploreu la gamma completa de detectors i monitors de gas Smart Sensor, que inclouen detectors multigas, monogas i especialitzats per a diverses aplicacions industrials i de seguretat. View especificacions, característiques i detalls d'embalatge.
Preview Smart Sensor ST9604 Digital Sound Level Meter - Technical Data Sheet by ICHEMING