Balluff MIC+130/D/TC

MIC+130/D/TC Ultrasonic Sensor

Manual d'instruccions

Introducció

This manual provides detailed instructions for the installation, operation, and maintenance of the Balluff MIC+130/D/TC Ultrasonic Sensor. This M30 ultrasonic sensor is designed for precise distance measurement and object detection within a range of 200-2000mm, featuring PNP NO/NC outputs and an M12 connector. Please read this manual thoroughly before using the device to ensure safe and efficient operation.

Instruccions de seguretat

Contingut del paquet

Verifiqueu que tots els components siguin presents i no estiguin danyats en desembalar-los:

Balluff MIC+130/D/TC Ultrasonic Sensor with two mounting nuts

Figura 1: The Balluff MIC+130/D/TC Ultrasonic Sensor, a cylindrical M30 threaded device with a blue cap and a white sensing face, shown alongside two hexagonal metal mounting nuts. The sensor body is metallic and ribbed, indicating a robust construction. The blue cap features control buttons and labeling for the model number and brand.

Configuració i instal·lació

1. Muntatge

  1. Select a suitable mounting location that provides a clear line of sight to the target object and is free from excessive acoustic noise or air turbulence.
  2. Insert the sensor into a pre-drilled M30 hole.
  3. Secure the sensor using the two provided M30 mounting nuts. Ensure it is firmly tightened to prevent movement.
  4. Orient the sensor's sensing face directly towards the target object.

2. Cablatge

The MIC+130/D/TC sensor uses an M12 connector. Refer to the sensor's label or technical documentation for the exact pinout. A typical M12 4-pin connector wiring for PNP sensors is as follows:

Connect the sensor to a compatible power supply (typically 10-30V DC) and the control system inputs. Ensure all connections are secure and insulated.

Instruccions de funcionament

Once properly installed and wired, the MIC+130/D/TC sensor is ready for operation. The sensor typically features teach-in functionality or adjustable parameters via buttons on the sensor body or through a software interface (if applicable). For detailed configuration, refer to the specific Balluff datasheet for the MIC+130/D/TC model.

Funcionament bàsic:

  1. Encès: Apply power to the sensor. An LED indicator (if present) should illuminate, indicating power.
  2. Detecció: The sensor emits ultrasonic waves and detects their reflection. When an object enters the detection range (200-2000mm), the output (PNP NO/NC) will switch state according to its configuration.
  3. Estat de sortida: Monitor the output signal at the M12 connector to confirm object detection or distance measurement.

Teach-in Function (if available):

Many ultrasonic sensors allow for teach-in of switching points. This typically involves pressing a button on the sensor while the target object is at the desired detection distance. Consult the sensor's specific datasheet for detailed teach-in procedures.

Manteniment

The MIC+130/D/TC sensor is designed for low maintenance. Regular inspection and cleaning are recommended to ensure optimal performance.

Resolució de problemes

ProblemaCausa possibleSolució
Sensor not powering on (no LED indication)Sense subministrament d'alimentació; cablejat incorrecte; subministrament d'alimentació defectuós.Comproveu les connexions d'alimentació i el volumtage. Verify wiring according to the pinout. Test power supply.
Sensor not detecting objects or erratic detectionSensing face dirty; object out of range; acoustic interference; incorrect teach-in.Clean sensing face. Ensure object is within 200-2000mm range. Reduce acoustic noise. Re-perform teach-in procedure.
Output not switchingIncorrect wiring; faulty output circuit; sensor not detecting.Verify output wiring (PNP NO/NC). Check if sensor is detecting (e.g., via LED). Replace sensor if output circuit is confirmed faulty.

Especificacions

Garantia i Suport

Balluff products are manufactured to high quality standards. For information regarding warranty terms, technical support, or service, please contact your local Balluff representative or visit the official Balluff website. Please have your model number (MIC+130/D/TC) and serial number (if applicable) ready when contacting support.

Official Balluff Weblloc: www.balluff.com

Documents relacionats - MIC+130/D/TC

Preview Bloc de connexions Balluff BPI 4M4A5P-2K-B0-KPXB0-030: especificacions tècniques i cablejat
Especificacions tècniques detallades, dades elèctriques, condicions ambientals, informació sobre materials, dades mecàniques, pinouts dels connectors i diagrames de cablejat per al bloc de connexions Balluff BPI 4M4A5P-2K-B0-KPXB0-030 (codi de comanda: BPI009W).
Preview Convertidors analògics i d'E/S de camp IO-Link de Balluff: característiques i especificacions
Exploreu els mestres, concentradors i convertidors analògics d'E/S de camp IO-Link de Balluff. Aquest document detalla les característiques, les especificacions tècniques i les assignacions de pins per a una connectivitat d'automatització industrial perfecta.
Preview Balluff BF-IDM30 RFID Reader Operating Guide
Comprehensive operating guide for the Balluff BF-IDM30 RFID Reader. Covers device purpose, connection, installation, setup, operation, status indicators, electrical and mechanical specifications, and regulatory compliance information for FCC and ISED Canada.
Preview Sensor fotoelèctric Balluff BLA 50D-001-S115: especificacions tècniques i funcionament
Especificacions tècniques detallades, característiques i guia operativa per al sensor fotoelèctric Balluff BLA 50D-001-S115. Inclou dades elèctriques, característiques òptiques, abast, connectivitat i informació de seguretat.
Preview Balluff BNI EIP-508-105-Z015-C06 EtherNet/IP™ IP67 Modules User's Guide
Comprehensive user's guide for the Balluff BNI EIP-508-105-Z015-C06 EtherNet/IP™ and IO-Link IP67 industrial module. Details installation, configuration, technical specifications, and integration for automation systems.
Preview Balluff BNI IOL-102-002-Z019 IO-Link 1.1 Sensor Hub User Guide
Comprehensive user guide for the Balluff BNI IOL-102-002-Z019 IO-Link 1.1 sensor hub, detailing installation, configuration, technical specifications, and troubleshooting for industrial automation applications.