1. Introducció
The Mastercool 55850 Intellasense Leak Detector Kit is a professional-grade instrument designed for the accurate detection of both refrigerant and combustible gas leaks. This comprehensive kit provides technicians with the necessary tools for efficient and reliable leak detection in HVAC, automotive, and industrial applications. Its advanced sensor technology and user-friendly interface ensure precise readings and ease of operation.
2. Informació de seguretat
Always observe the following safety precautions when operating the Mastercool 55850 Leak Detector:
- Equips de protecció individual: Always wear the included UV safety glasses (Mastercool P/N 92398) and other appropriate personal protective equipment (PPE) when performing leak detection, especially when using the UV light or handling refrigerants.
- Ventilació: Ensure adequate ventilation in the work area, particularly when dealing with combustible gases or refrigerants, which can displace oxygen or be flammable.
- Gasos inflamables: Exercise extreme caution when detecting combustible gases. Avoid open flames, sparks, or other ignition sources in areas where flammable gases may be present.
- Seguretat de la bateria: Use only the specified D alkaline batteries. Do not mix old and new batteries, or different types of batteries. Dispose of batteries properly.
- Manipulació de la sonda: The flexible probe contains sensitive electronics. Avoid sharp bends or excessive force that could damage the probe or sensor tip.
- Emmagatzematge: Store the unit and its components in the provided hard case in a cool, dry place away from direct sunlight and extreme temperatures.
3. Producte acabatview and Kit Contents
The Mastercool 55850 Intellasense Leak Detector Kit is a comprehensive solution for professional leak detection. It includes the main 55800 detector unit and a range of essential accessories.
Contingut del kit:
- Mastercool 55800 Intellasense Leak Detector
- LED UV Light (Mastercool P/N 53513)
- UV Safety Glasses (Mastercool P/N 92398)
- 2 x D Alkaline Batteries
- Vial de prova de fuites
- Filtres de substitució
- Molded Hard Carrying Case

Característiques principals:
- Dual Gas Detection: Detects all common refrigerants (CFCs, HCFCs, HFCs, R1234yf, R410a, R32) and combustible gases (e.g., hydrogen-based trace gases).
- Long-Life Sensor: Equipped with a heated metal oxide (tin oxide) sensor providing up to 2000 hours of reliable operation.
- Super Sensitive Mode: Enhances detection accuracy for low-level refrigerant leaks, such as R1234yf and R407C.
- Pantalla LCD: A large LCD screen provides real-time visual feedback on leak intensity (via vertical bars), sensitivity level, battery status, and diagnostic error codes.
- Intelligent Flexible Probe: Features a 16-inch (40.6 cm) flexible probe with an intelligent sensing tip that minimizes false readings by adjusting for environmental interference.
- Controls fàcils d'utilitzar: Intuitive controls for Volume/Mute, Sensitivity (High/Medium/Low), and Peak Hold/Freeze Signal functions.


4. Configuració
4.1. Instal·lació de la bateria
- Locate the battery compartment on the underside of the detector unit.
- Obriu la tapa del compartiment de la bateria.
- Insert two (2) D alkaline batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
- Tanqueu bé la tapa del compartiment de la bateria.
4.2. Initial Power-On and Warm-Up
- Manteniu premut el botó d'engegada (⏻) on the keypad until the unit powers on.
- The LCD display will show a warm-up sequence. The unit requires approximately 30-60 seconds to warm up and stabilize the sensor. During this time, the display may show "WAIT".
- Once warm-up is complete, the display will indicate "READY" and the unit is ready for operation.
5. Instruccions de funcionament
5.1. Encès / apagat
- Per encendre: Manteniu premut el botó d'engegada (⏻) until the unit activates. Allow for the warm-up period.
- Per apagar: Manteniu premut el botó d'engegada (⏻) until the unit shuts down.
5.2. Ajust dels nivells de sensibilitat
The detector offers three sensitivity levels: High (H), Medium (M), and Low (L). Use the 'HML' button to cycle through these settings.
- Alt (H): For detecting very small leaks or when the leak source is unknown.
- Mitjà (M): General purpose detection.
- Baix (L): For large leaks or when pinpointing a known leak source.
5.3. Super Sensitive Function
To activate the Super Sensitive function for enhanced detection of minute leaks (e.g., R1234yf, R407C), ensure the unit is in High sensitivity mode, then refer to the specific instructions in the full manual for activation, as this may involve a combination of button presses or a dedicated mode.

5.4. Interpreting the LCD Display
The LCD provides critical information during operation:
- Leak Intensity Bars: Vertical bars illuminate to indicate the concentration of detected gas. More bars signify a stronger leak.
- Nivell de sensibilitat: Displays 'H', 'M', or 'L' to show the current sensitivity setting.
- Estat de la bateria: An icon indicates the remaining battery life. Replace batteries when the low battery indicator appears.
- Missatges d'estat: "WAIT" during warm-up, "READY" when operational, "PEAK" when Peak Hold is active, "MUTE" when audio is off.
- Codis d'error: Specific codes (e.g., E8) may appear to indicate sensor issues or other malfunctions. Refer to the Troubleshooting section for details.
5.5. Using the Flexible Probe
The 16-inch flexible probe allows access to hard-to-reach areas. Slowly move the probe tip around suspected leak points, maintaining a consistent distance from the surface. The intelligent sensing tip is designed to minimize false alarms from environmental factors.

5.6. Peak Hold Function
Press the 'PEAK' button to activate the Peak Hold function. This feature locks the highest detected leak signal on the display while allowing the unit to continue scanning for additional leaks. This is useful for identifying the strongest leak point in an area with multiple small leaks.
5.7. Volume/Mute Control
Press the 'VOLUME/MUTE' button to toggle the audible alarm on or off. The display will show "MUTE" when the audio is disabled.
5.8. Using the UV Light and Safety Glasses
For systems charged with UV dye, the included LED UV light (53513) and UV safety glasses (92398) can be used to visually locate leaks. Shine the UV light on suspected areas while wearing the safety glasses to observe a bright green/yellow glow where the dye has escaped.

6. Manteniment
6.1. Substitució del sensor
The heated metal oxide sensor has an approximate lifespan of 2000 hours. When sensor performance degrades or an error code related to the sensor appears, it should be replaced. Refer to the full manual for detailed sensor replacement instructions.
6.2. Substitució del filtre
The probe tip contains a filter that prevents debris from entering the sensor. Replace the filter periodically, or if it appears dirty or clogged, using the included replacement filters. A clogged filter can affect detection accuracy.
6.3. Neteja de la unitat
Netegeu l'exterior del detector amb un drap net.amp cloth. Do not use abrasive cleaners or solvents. Ensure the unit is powered off before cleaning.
6.4. Substitució de la bateria
Replace the D batteries when the low battery indicator appears on the LCD. Follow the battery installation steps outlined in Section 4.1.
6.5. Emmagatzematge
When not in use, store the Mastercool 55850 Leak Detector and all accessories in its original hard carrying case. This protects the unit from dust, moisture, and physical damage.
7. Solució De Problemes
| Problema | Causa possible | Solució |
|---|---|---|
| La unitat no s'encén. | Piles gastades o instal·lades incorrectament. | Check battery polarity. Replace batteries with new D alkaline batteries. |
| Low sensitivity or no detection. | Sensor nearing end of life; clogged filter; incorrect sensitivity setting; environmental interference. | Replace sensor (if applicable). Replace probe filter. Adjust sensitivity to 'H' or 'Super Sensitive' mode. Move to a less turbulent area. |
| False alarms or erratic readings. | Strong air currents; presence of other gases/vapors; sensor contamination. | Minimize air movement around the probe. Ensure the area is free of non-target gases (e.g., cleaning solvents). Clean or replace sensor/filter. |
| LCD displays "E8" or other error code. | Sensor malfunction or internal error. | Power off the unit, wait 30 seconds, then power on again. If the error persists, the sensor may need replacement or the unit requires servicing. Contact Mastercool support. |
8. Especificacions
| Número de model | 55850 |
| Tipus de sensor | Heated Tin Oxide |
| Detecta | CFCs, HCFCs, HFCs (including R1234yf, R410a, R32), Combustible Gases (e.g., Hydrogen) |
| Sensitivity (Refrigerant) | 0.15 oz/yr (High), 0.25 oz/yr (Medium), 0.5 oz/yr (Low) |
| Temperatura de funcionament | De 0 °F a 140 °F (-17.8 °C a 60 °C) |
| Font d'alimentació | 2 x D Alkaline Batteries (included) |
| Durada de la bateria | Aproximadament 60 hores |
| Longitud de la sonda | 16 inches (40.6 cm) flexible |
| Dimensions del producte | 12"D x 9"W x 4.5"H (approximate case dimensions) |
| Pes de l'article | 8.5 Pounds (including case and accessories) |
9. Garantia i Suport
The Mastercool 55850 Intellasense Leak Detector Kit is backed by Mastercool's reliable service and U.S.-based customer support team. For warranty information, technical assistance, or service inquiries, please refer to the contact details provided in the product packaging or visit the official Mastercool weblloc. Conserveu el rebut de compra per a reclamacions de garantia.