Akicon BPT16-14EL-L12

Manual d'usuari del ventilador d'extracció de bany Akicon BPT16-14EL-L12 amb llum LED

Model: BPT16-14EL-L12

Introducció

This manual provides essential information for the safe installation, operation, and maintenance of your Akicon BPT16-14EL-L12 Bathroom Exhaust Fan with LED Light. Please read these instructions thoroughly before installation and use, and retain them for future reference.

The Akicon BPT16-14EL-L12 exhaust fan is designed to effectively remove moisture and odors from bathrooms and similar indoor spaces up to 85 square feet. It features a quiet operation at 1.5 sones and an integrated 12W LED light for illumination.

Akicon BPT16-14EL-L12 Bathroom Exhaust Fan with LED Light

Descripció de la imatge: Una part frontal view of the Akicon BPT16-14EL-L12 bathroom exhaust fan, showcasing its white grille cover with integrated LED light and the metal housing with a black duct connector.

Informació de seguretat

ADVERTÈNCIA: Per reduir el risc d'incendi, descàrrega elèctrica o lesions a les persones, observeu el següent:

  • Els treballs d'instal·lació i el cablejat elèctric han de ser realitzats per persones qualificades d'acord amb tots els codis i estàndards aplicables, inclosos els codis i normes de construcció antiincendis.
  • Always disconnect power at the service panel before wiring or servicing the unit.
  • This unit is HVI-certified and cUL listed for use over bathtubs and showers when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.
  • No utilitzeu aquest ventilador amb cap dispositiu de control de velocitat d’estat sòlid.
  • Never place any object into the fan blades.
  • Assegureu-vos que el ventilador estigui correctament connectat a terra.
  • Duct work must be installed with a minimum number of turns and runs to ensure optimal airflow.

Contingut del paquet

Verifiqueu que tots els components siguin presents abans de començar la instal·lació:

  • Exhaust Fan Housing Assembly
  • Grille Cover with Integrated LED Light
  • 12W E26 Base LED Bulb (pre-installed or separate)
  • Installation Hardware (screws, wire connectors)
  • Manual d'usuari (aquest document)

Especificacions

CaracterísticaEspecificació
MarcaAkicon
Número de modelBPT16-14EL-L12
Capacitat de cabal d'aire90 peus cúbics per minut (CFM)
Nivell de soroll1.5 sons
Font d'alimentacióAC
Voltage120 Volts
Llum LED Wattage12 watts
Temperatura de color de la llum LED5000K (blanc fred)
Housing Dimensions (L x W x H)9-3/8" x 9-3/8" x 7-5/16"
Grille Cover Size11 cm x 11 cm
Mida del conducterodona de 4 polzades
Mida recomanada de l'habitacióFins a 85 peus quadrats
CertificacionsHVI, cUL Listed
Pes de l'article8.83 lliures

Configuració i instal·lació

This section outlines the general steps for installing the Akicon BPT16-14EL-L12 exhaust fan. For detailed diagrams and specific instructions, refer to the included installation guide or consult a qualified electrician.

1. Consideracions prèvies a la instal·lació

  • Measure Room Size: Ensure the fan's 90 CFM capacity is suitable for your room (up to 85 sq. ft.).
  • Obertura del sostre: The recommended ceiling opening size is approximately 9-7/8" x 9-7/8". If replacing an existing fan, measure the current opening. If the existing opening is smaller, it will need to be enlarged to accommodate the new housing.
  • Conductes: Plan for a 4-inch round duct connection. Use rigid metal ducting for best performance.
  • Cablejat elèctric: Ensure a 120V AC power supply is available. The fan and light can be wired to operate jointly or separately via wall switches.
Diagram showing housing, grille, and ceiling opening dimensions for the Akicon exhaust fan.

Descripció de la imatge: This image displays the critical dimensions for installation. It shows the fan housing size as 9-3/8" x 9-3/8" x 7-5/16", the grille cover size as 11" x 11", and the recommended ceiling opening size as 9-7/8" x 9-7/8". This helps ensure proper fit during installation.

Installation notice for Akicon exhaust fan showing housing dimensions and required ceiling opening.

Descripció de la imatge: An installation notice highlighting the housing dimensions (9.4" x 9.4" x 7.7") and emphasizing that the opening hole size should be based on the housing size. It advises checking existing opening sizes for replacements and cutting the hole to match the new housing if necessary.

2. Mounting the Fan Housing

  • Apagueu l'alimentació a l'interruptor.
  • Cut the ceiling opening to the specified dimensions (approx. 9-7/8" x 9-7/8").
  • Secure the fan housing to ceiling joists using appropriate fasteners. The housing is designed for screw-in installation. Ensure it is firmly attached to prevent vibration and noise.
Diagram illustrating attic and soffit installation types for a bathroom exhaust fan.

Descripció de la imatge: This diagram shows two common installation scenarios: attic and soffit. It illustrates how the fan can be ducted to exhaust air outside, emphasizing the importance of proper ducting for effective ventilation.

3. Connexió de conductes

  • Connect a 4-inch round duct to the fan's exhaust collar. Secure with duct tape or clamps.
  • Route the duct to an exterior vent cap, ensuring minimal bends and a slight downward slope away from the fan to prevent condensation buildup.
Detailed installation diagram for the Akicon bathroom exhaust fan.

Descripció de la imatge: A comprehensive installation diagram showing the fan housing, duct connection, and electrical wiring points. It provides a visual guide for the step-by-step installation process within a ceiling.

4. Cablejat elèctric

  • Open the wiring compartment on the fan housing.
  • Connect the household wiring to the fan's wiring according to local electrical codes. The fan and light have separate wires, allowing for independent operation if desired (e.g., separate wall switches for fan and light).
  • Ensure all connections are secure and properly insulated. Close the wiring compartment cover.

5. Install Grille Cover

  • If the LED bulb is not pre-installed, screw the 12W E26 base LED bulb into the socket.
  • Attach the grille cover to the fan housing. Typically, this involves inserting mounting springs into slots in the housing and pushing the grille firmly against the ceiling.

Once installation is complete, restore power at the circuit breaker and test the fan and light functions.

Instruccions de funcionament

The Akicon BPT16-14EL-L12 exhaust fan and LED light are designed for simple operation via standard wall switches.

  • Funcionament del ventilador: Flip the designated wall switch to turn the exhaust fan ON or OFF.
  • Funcionament lleuger: Flip the designated wall switch to turn the LED light ON or OFF.
  • If wired separately, the fan and light can be controlled independently. If wired jointly, both will activate simultaneously.

For optimal moisture and odor removal, operate the fan during and after showering or bathing for at least 15-20 minutes.

Manteniment

Regular maintenance ensures optimal performance and longevity of your exhaust fan. Always disconnect power at the circuit breaker before performing any maintenance.

1. Cleaning the Grille Cover

  • Gently pull down the grille cover to detach it from the housing springs.
  • Wash the grille cover with mild soap and water. Rinse thoroughly and dry completely before reattaching.
Primer pla view of the Akicon exhaust fan grille.

Descripció de la imatge: Un detallat view of the fan's white grille cover, showing the ventilation slots and the central LED light panel. This component is easily removable for cleaning.

2. Cleaning the Fan Interior

  • With the grille removed and power off, carefully wipe down the fan blades and interior of the housing with a damp tela.
  • Do not allow water to enter the motor or electrical components.
  • Assegureu-vos que totes les peces estiguin seques abans de restablir l'alimentació.

3. LED Bulb Replacement

  • Assegureu-vos que l'alimentació estigui apagada.
  • Remove the grille cover.
  • Unscrew the old E26 base LED bulb and replace it with a new 12W E26 base LED bulb.
  • Reattach the grille cover and restore power.

Resolució de problemes

If you encounter issues with your Akicon exhaust fan, refer to the following common problems and solutions:

ProblemaCausa possibleSolució
Fan does not operate / Light does not turn onNo power supply; Loose wiring; Faulty switch; Blown fuse/tripped breakerCheck power at the circuit breaker. Ensure all wiring connections are secure. Test the wall switch. Replace fuse or reset breaker.
Fan is excessively noisyLoose mounting; Obstruction in fan blades; Dirty fan blades/motor; Improper ductingEnsure fan housing is securely mounted. Disconnect power and check for obstructions. Clean fan blades and motor. Inspect ductwork for kinks or blockages.
Mal rendiment de ventilacióDucting issues (too long, too many bends, wrong size); Blocked exterior vent; Room size exceeds fan capacityInspect ductwork for proper installation and clear any blockages. Ensure exterior vent is clear. Verify fan CFM matches room size.
LED light flickers or is dimLoose bulb; Faulty bulb; Wiring issueEnsure bulb is screwed in tightly. Replace the LED bulb. Check electrical connections to the light.

If the problem persists after attempting these solutions, please contact Akicon customer support.

Informació de la garantia

The Akicon BPT16-14EL-L12 Bathroom Exhaust Fan with LED Light comes with a Garantia limitada d'3 any des de la data de compra. Aquesta garantia cobreix els defectes de materials i de mà d'obra en ús normal.

The warranty does not cover damage resulting from improper installation, misuse, abuse, accident, neglect, or unauthorized repair or modification. Proof of purchase is required for all warranty claims.

Atenció al client

For any questions, technical assistance, or warranty claims, please contact Akicon customer service. Have your model number (BPT16-14EL-L12) and proof of purchase ready when contacting support.

Contact information can typically be found on the Akicon official weblloc web o a través de la vostra plataforma de compra.

Documents relacionats - BPT16-14EL-L12

Preview AKICON 110 CFM Bathroom Exhaust Fan with RGB LED, Humidity Sensor, 3CCT & Night Light - Use and Care Guide
Comprehensive use and care guide for the AKICON 110 CFM Bathroom Exhaust Fan, featuring RGB LED mode, humidity sensor, 3CCT, and night light. Includes installation instructions for new and existing construction, troubleshooting, and maintenance.
Preview Guia d'ús i cura del ventilador d'extracció de bany AKICON 110 CFM amb LED RGB i sensor d'humitat
Detailed use and care guide for the AKICON 110 CFM Bathroom Exhaust Fan. Covers installation (new and existing construction), specifications, safety information, maintenance, troubleshooting, and remote operation for models AKHR110-RGB2-W, AKHR110-RGB2-B, and AKHR110-RGB2-S.
Preview Extractor de bany AKICON de 110 CFM amb LED RGB, sensor d'humitat, 3CCT i llum nocturna: guia d'ús i cura
Comprehensive use and care guide for the AKICON 110 CFM Bathroom Exhaust Fan, featuring RGB LED mode, humidity sensor, 3CCT color temperature, and night light. Includes installation instructions, safety information, troubleshooting, and warranty details.
Preview AKICON BPT14-80CL Bathroom Ventilation Fan with Light Use and Care Guide
Comprehensive use and care guide for the AKICON BPT14-80CL Bathroom Ventilation Fan with Light, detailing product specifications, installation, maintenance, troubleshooting, and warranty information.
Preview AKICON AK1390N2-W/B/S Ventilador de bany amb llum Guia d'ús i cura
Guia completa d'ús i cura del ventilador de bany AKICON AK1390N2-W/B/S amb llum LED. Inclou instruccions d'instal·lació, informació de seguretat, manteniment, resolució de problemes i detalls de la garantia.
Preview Guia de l'usuari de l'interruptor d'humitat AK-SW-FLHT
Guia d'usuari per a l'interruptor d'humitat AKICON AK-SW-FLHT, que detalla les especificacions, la configuració, els modes de funcionament i les instruccions de cablejat per controlar els ventiladors i els llums en funció dels nivells d'humitat.