Introducció
This manual provides essential information for the safe installation, operation, and maintenance of your Akicon BPT16-14EL-L12 Bathroom Exhaust Fan with LED Light. Please read these instructions thoroughly before installation and use, and retain them for future reference.
The Akicon BPT16-14EL-L12 exhaust fan is designed to effectively remove moisture and odors from bathrooms and similar indoor spaces up to 85 square feet. It features a quiet operation at 1.5 sones and an integrated 12W LED light for illumination.

Descripció de la imatge: Una part frontal view of the Akicon BPT16-14EL-L12 bathroom exhaust fan, showcasing its white grille cover with integrated LED light and the metal housing with a black duct connector.
Informació de seguretat
ADVERTÈNCIA: Per reduir el risc d'incendi, descàrrega elèctrica o lesions a les persones, observeu el següent:
- Els treballs d'instal·lació i el cablejat elèctric han de ser realitzats per persones qualificades d'acord amb tots els codis i estàndards aplicables, inclosos els codis i normes de construcció antiincendis.
- Always disconnect power at the service panel before wiring or servicing the unit.
- This unit is HVI-certified and cUL listed for use over bathtubs and showers when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.
- No utilitzeu aquest ventilador amb cap dispositiu de control de velocitat d’estat sòlid.
- Never place any object into the fan blades.
- Assegureu-vos que el ventilador estigui correctament connectat a terra.
- Duct work must be installed with a minimum number of turns and runs to ensure optimal airflow.
Contingut del paquet
Verifiqueu que tots els components siguin presents abans de començar la instal·lació:
- Exhaust Fan Housing Assembly
- Grille Cover with Integrated LED Light
- 12W E26 Base LED Bulb (pre-installed or separate)
- Installation Hardware (screws, wire connectors)
- Manual d'usuari (aquest document)
Especificacions
| Característica | Especificació |
|---|---|
| Marca | Akicon |
| Número de model | BPT16-14EL-L12 |
| Capacitat de cabal d'aire | 90 peus cúbics per minut (CFM) |
| Nivell de soroll | 1.5 sons |
| Font d'alimentació | AC |
| Voltage | 120 Volts |
| Llum LED Wattage | 12 watts |
| Temperatura de color de la llum LED | 5000K (blanc fred) |
| Housing Dimensions (L x W x H) | 9-3/8" x 9-3/8" x 7-5/16" |
| Grille Cover Size | 11 cm x 11 cm |
| Mida del conducte | rodona de 4 polzades |
| Mida recomanada de l'habitació | Fins a 85 peus quadrats |
| Certificacions | HVI, cUL Listed |
| Pes de l'article | 8.83 lliures |
Configuració i instal·lació
This section outlines the general steps for installing the Akicon BPT16-14EL-L12 exhaust fan. For detailed diagrams and specific instructions, refer to the included installation guide or consult a qualified electrician.
1. Consideracions prèvies a la instal·lació
- Measure Room Size: Ensure the fan's 90 CFM capacity is suitable for your room (up to 85 sq. ft.).
- Obertura del sostre: The recommended ceiling opening size is approximately 9-7/8" x 9-7/8". If replacing an existing fan, measure the current opening. If the existing opening is smaller, it will need to be enlarged to accommodate the new housing.
- Conductes: Plan for a 4-inch round duct connection. Use rigid metal ducting for best performance.
- Cablejat elèctric: Ensure a 120V AC power supply is available. The fan and light can be wired to operate jointly or separately via wall switches.

Descripció de la imatge: This image displays the critical dimensions for installation. It shows the fan housing size as 9-3/8" x 9-3/8" x 7-5/16", the grille cover size as 11" x 11", and the recommended ceiling opening size as 9-7/8" x 9-7/8". This helps ensure proper fit during installation.

Descripció de la imatge: An installation notice highlighting the housing dimensions (9.4" x 9.4" x 7.7") and emphasizing that the opening hole size should be based on the housing size. It advises checking existing opening sizes for replacements and cutting the hole to match the new housing if necessary.
2. Mounting the Fan Housing
- Apagueu l'alimentació a l'interruptor.
- Cut the ceiling opening to the specified dimensions (approx. 9-7/8" x 9-7/8").
- Secure the fan housing to ceiling joists using appropriate fasteners. The housing is designed for screw-in installation. Ensure it is firmly attached to prevent vibration and noise.

Descripció de la imatge: This diagram shows two common installation scenarios: attic and soffit. It illustrates how the fan can be ducted to exhaust air outside, emphasizing the importance of proper ducting for effective ventilation.
3. Connexió de conductes
- Connect a 4-inch round duct to the fan's exhaust collar. Secure with duct tape or clamps.
- Route the duct to an exterior vent cap, ensuring minimal bends and a slight downward slope away from the fan to prevent condensation buildup.

Descripció de la imatge: A comprehensive installation diagram showing the fan housing, duct connection, and electrical wiring points. It provides a visual guide for the step-by-step installation process within a ceiling.
4. Cablejat elèctric
- Open the wiring compartment on the fan housing.
- Connect the household wiring to the fan's wiring according to local electrical codes. The fan and light have separate wires, allowing for independent operation if desired (e.g., separate wall switches for fan and light).
- Ensure all connections are secure and properly insulated. Close the wiring compartment cover.
5. Install Grille Cover
- If the LED bulb is not pre-installed, screw the 12W E26 base LED bulb into the socket.
- Attach the grille cover to the fan housing. Typically, this involves inserting mounting springs into slots in the housing and pushing the grille firmly against the ceiling.
Once installation is complete, restore power at the circuit breaker and test the fan and light functions.
Instruccions de funcionament
The Akicon BPT16-14EL-L12 exhaust fan and LED light are designed for simple operation via standard wall switches.
- Funcionament del ventilador: Flip the designated wall switch to turn the exhaust fan ON or OFF.
- Funcionament lleuger: Flip the designated wall switch to turn the LED light ON or OFF.
- If wired separately, the fan and light can be controlled independently. If wired jointly, both will activate simultaneously.
For optimal moisture and odor removal, operate the fan during and after showering or bathing for at least 15-20 minutes.
Manteniment
Regular maintenance ensures optimal performance and longevity of your exhaust fan. Always disconnect power at the circuit breaker before performing any maintenance.
1. Cleaning the Grille Cover
- Gently pull down the grille cover to detach it from the housing springs.
- Wash the grille cover with mild soap and water. Rinse thoroughly and dry completely before reattaching.

Descripció de la imatge: Un detallat view of the fan's white grille cover, showing the ventilation slots and the central LED light panel. This component is easily removable for cleaning.
2. Cleaning the Fan Interior
- With the grille removed and power off, carefully wipe down the fan blades and interior of the housing with a damp tela.
- Do not allow water to enter the motor or electrical components.
- Assegureu-vos que totes les peces estiguin seques abans de restablir l'alimentació.
3. LED Bulb Replacement
- Assegureu-vos que l'alimentació estigui apagada.
- Remove the grille cover.
- Unscrew the old E26 base LED bulb and replace it with a new 12W E26 base LED bulb.
- Reattach the grille cover and restore power.
Resolució de problemes
If you encounter issues with your Akicon exhaust fan, refer to the following common problems and solutions:
| Problema | Causa possible | Solució |
|---|---|---|
| Fan does not operate / Light does not turn on | No power supply; Loose wiring; Faulty switch; Blown fuse/tripped breaker | Check power at the circuit breaker. Ensure all wiring connections are secure. Test the wall switch. Replace fuse or reset breaker. |
| Fan is excessively noisy | Loose mounting; Obstruction in fan blades; Dirty fan blades/motor; Improper ducting | Ensure fan housing is securely mounted. Disconnect power and check for obstructions. Clean fan blades and motor. Inspect ductwork for kinks or blockages. |
| Mal rendiment de ventilació | Ducting issues (too long, too many bends, wrong size); Blocked exterior vent; Room size exceeds fan capacity | Inspect ductwork for proper installation and clear any blockages. Ensure exterior vent is clear. Verify fan CFM matches room size. |
| LED light flickers or is dim | Loose bulb; Faulty bulb; Wiring issue | Ensure bulb is screwed in tightly. Replace the LED bulb. Check electrical connections to the light. |
If the problem persists after attempting these solutions, please contact Akicon customer support.
Informació de la garantia
The Akicon BPT16-14EL-L12 Bathroom Exhaust Fan with LED Light comes with a Garantia limitada d'3 any des de la data de compra. Aquesta garantia cobreix els defectes de materials i de mà d'obra en ús normal.
The warranty does not cover damage resulting from improper installation, misuse, abuse, accident, neglect, or unauthorized repair or modification. Proof of purchase is required for all warranty claims.
Atenció al client
For any questions, technical assistance, or warranty claims, please contact Akicon customer service. Have your model number (BPT16-14EL-L12) and proof of purchase ready when contacting support.
Contact information can typically be found on the Akicon official weblloc web o a través de la vostra plataforma de compra.