1. Introducció
This manual provides essential instructions for the installation, operation, and maintenance of your EPEVER 80A MPPT Solar Charge Controller. This device is designed to manage the power flow from your solar panels to your battery bank, ensuring efficient charging and protecting your batteries from overcharge and over-discharge. It supports 12V, 24V, 36V, and 48V battery systems automatically and is compatible with various lead-acid battery types including Sealed, AGM, Gel, and Flooded batteries.
2. Informació de seguretat
Llegiu atentament totes les instruccions i advertències abans de la instal·lació i el funcionament. Si no seguiu aquestes instruccions, podeu patir descàrregues elèctriques, incendis o lesions greus.
- Ensure all wiring is correctly polarized and securely connected. Incorrect wiring can damage the controller and other components.
- Always disconnect the battery first, then the solar panel, before performing any maintenance or disconnection. Reconnect in reverse order: solar panel first, then battery.
- Install the controller in a well-ventilated area, away from flammable materials and corrosive gases.
- The controller is designed for indoor use. Protect it from direct sunlight, high temperatures, and moisture.
- Use appropriate circuit breakers or fuses for both the solar panel and battery circuits to prevent overcurrent.
- This device is a common negative ground controller. Ensure proper grounding.
- Do not attempt to disassemble or repair the controller yourself. Contact qualified service personnel.
3. Producte acabatview
3.1 Característiques clau
- Sistema automàtic voltage identification: 12V/24V/36V/48V DC.
- Advanced MPPT technology with ultra-fast tracking speed (up to 99.5% efficiency).
- Maximum DC/DC transfer efficiency up to 98.7%.
- Automatic control system to limit charging power and current.
- Real-time energy recording and statistical functions.
- Funció de compensació de temperatura de la bateria.
- Isolated RS-485 communication interface with MODBUS protocol.
- Support for parallel operation of up to 8 units to expand system capacity.
- Compatible with Sealed, AGM, Gel, and Flooded lead-acid batteries.
3.2 Dimensions físiques

Figura 3.2.1: Physical dimensions of the EPEVER 80A MPPT Solar Charge Controller. The controller measures approximately 394mm (L) x 240mm (W) x 134mm (H).
The controller has a robust design with integrated heat sinks for efficient thermal management. The overall dimensions are approximately 394mm in length, 240mm in width, and 134mm in height. The mounting holes are designed for secure installation.
3.3 Identificació de components

Figura 3.3.1: Davant view of the EPEVER 80A MPPT Solar Charge Controller with labeled components.
- Fusible: Overcurrent protection for the battery circuit.
- Terminals de bateria: Connect to the battery bank.
- PV Terminals: Connect to the solar panel array.
- Load Control Relay: Output for connecting DC loads (if applicable).
- RBVS Port: Volum de bateria remotatage Sensor port.
- Utility/Generator Relay ON: Control signal for external utility/generator.
- Utility/Generator Relay OFF: Control signal for external utility/generator.
- RS485 Port (5VDC/200mA): Communication port for remote monitoring or parallel connection.
- RTS Port: Remote Temperature Sensor port.
- Generator and Load Relay Enable: Control input for generator and load relays.
- PV Reverse Polarity Alarm Indicator: LED indicator for PV reverse polarity.
- Terminal de terra: For system grounding.
- Botó SELECCIÓ: Used to navigate menu options.
- Indicador LED de càrrega: Indica l'estat de càrrega.
- Fault LED Indicator: Indica errors del sistema.
- Botó ENTER: S'utilitza per confirmar seleccions.
3.4 Interfície de visualització

Figura 3.4.1: Example screens of the LCD display showing various system parameters.
The integrated LCD provides real-time monitoring of system parameters such as PV voltage, corrent de càrrega, volum de bateriatage, load status, and temperature. Use the "SELECT" and "ENTER" buttons to navigate through the display screens and adjust settings.
4. Configuració i instal·lació
Proper installation is crucial for the safe and efficient operation of your solar charge controller. Follow these steps carefully.
4.1 Muntatge del controlador
- Choose a vertical mounting location that is well-ventilated and protected from direct sunlight, high temperatures, and moisture.
- Ensure there is sufficient clearance around the controller for heat dissipation, especially above and below the heat sink fins.
- Mount the controller securely using appropriate fasteners for the mounting surface.
4.2 Connexions de cablejat
Important: Always connect the battery first, then the solar panel. Disconnect in the reverse order: solar panel first, then battery. Ensure all connections are tight and secure to prevent loose connections and overheating.

Figura 4.2.1: Standard connection diagram for the EPEVER 80A MPPT Solar Charge Controller with a single battery, PV panel, and AC load via an inverter.
- Connecteu la bateria: Connect the positive and negative terminals of the battery bank to the controller's battery terminals. Observe correct polarity. Use recommended cable size (e.g., 16mm² / 6AWG).
- Connecteu el panell solar: Connect the positive and negative terminals of the solar panel array to the controller's PV terminals. Ensure the PV open circuit voltage no supera els 150 VDC.
- Connecteu la càrrega (opcional): If using the load control feature, connect your DC load to the controller's load terminals.
- Connect Remote Temperature Sensor (RTS): Plug the RTS cable into the RTS port. This ensures accurate battery temperature compensation.
- Connect Remote Battery Voltage Sensor (RBVS) (Optional): Plug the RBVS cable into the RBVS port for more accurate battery voltage mesura.
- Posada a terra: Connect the grounding terminal of the controller to an earth ground.
4.3 Connexió en paral·lel (opcional)
The EPEVER 80A MPPT controller supports parallel operation of up to 8 units to increase system capacity. This requires an RS485 communication cable and proper configuration.

Figura 4.3.1: Diagram illustrating the parallel connection of multiple EPEVER MPPT controllers to a single battery bank.
For parallel connection, ensure all controllers are connected to the same battery bank and configured correctly via the RS485 communication port. Refer to the advanced user manual for detailed instructions on parallel setup and master/slave configuration.
4.4 Selecció del tipus de bateria
The controller supports various lead-acid battery types. It is crucial to select the correct battery type in the controller's settings to ensure optimal charging and battery longevity.
- Segellat: For sealed lead-acid batteries.
- AGA: For Absorbed Glass Mat batteries.
- Gel: For Gel cell batteries.
- Inundat: For flooded (wet cell) lead-acid batteries.
- Usuari: Allows for custom charging parameters for specific battery types (e.g., non-standard lead-acid or user-defined settings). Note: This controller is not designed for Lithium batteries.
Refer to your battery manufacturer's specifications for recommended charging voltages and select the corresponding type in the controller's menu. Incorrect battery type selection can damage your batteries.
5. Funcionament
5.1 Engegada inicial
After all connections are made and verified, the controller will power on automatically. The LCD display will show the current system status. The Charging LED indicator will illuminate when charging is active.
5.2 Monitorització de l'estat del sistema
Use the "SELECT" button to cycle through various display screens, showing parameters such as:
- PV Voltage (V) and Current (A)
- Voltage (V) and Charging Current (A)
- Volum de càrregatage (V) and Current (A)
- Battery Temperature (°C)
- Total Charged Energy (kWh)
- Total Discharged Energy (kWh)
5.3 Configuració dels paràmetres
To enter the parameter setting mode, press and hold the "ENTER" button for a few seconds. Use the "SELECT" button to navigate through parameters and the "ENTER" button to confirm changes. Parameters that can be adjusted include:
- Tipus de bateria
- Vol. De càrregatage Setpoints (Float, Boost, Equalization)
- Load Control Mode (e.g., always on, dusk to dawn, timer)
- Temps de llum de fons LCD
- Coeficient de compensació de temperatura
Refer to the detailed programming guide for specific values and advanced settings.
6. Manteniment
Un manteniment regular garanteix la longevitat i el rendiment òptim del vostre controlador de càrrega.
- Comproveu les connexions: Periodically inspect all wiring connections for tightness, corrosion, or damage. Tighten any loose connections.
- Netegeu el controlador: Keep the controller clean and free of dust and debris. Use a dry cloth to wipe the exterior. Ensure the heat sink fins are not obstructed.
- Inspeccionar per danys: Check for any physical damage to the casing, cables, or terminals.
- Monitoritzar el rendiment: Regularly check the display for normal operation and compare readings with expected values.
- Manteniment de la bateria: Follow your battery manufacturer's maintenance guidelines.
7. Solució De Problemes
This section outlines common issues and their potential solutions. If the problem persists, contact customer support.
7.1 Common Protections and Indicators
The controller includes several protection mechanisms. The Fault LED indicator will illuminate or flash to indicate a fault condition.
- PV Over Current/Power: The solar input power or current exceeds the controller's rated limits. The controller will automatically limit the charging. Check PV array size.
- PV Short Circuit: A short circuit in the solar panel wiring. Disconnect PV, check wiring, and reconnect.
- PV Reverse Polarity: Solar panel connected with incorrect polarity. Disconnect PV, correct wiring, and reconnect. The PV reverse polarity alarm indicator will be active.
- Night Reverse Charging: Current flowing from battery to PV at night. This is usually prevented by the controller; if it occurs, check PV wiring.
- Battery Over Voltage: Bateria voltage exceeds the overcharge protection setting. The controller will stop charging.
- Battery Over Discharge: Bateria voltage drops below the over-discharge protection setting. The load output will be disconnected.
- Sobreescalfament de la bateria: Battery temperature is too high. Charging current will be reduced or stopped. Ensure proper battery ventilation.
- Controller Overheating: Internal temperature of the controller is too high. Charging current will be reduced. Ensure adequate ventilation around the controller.
- TVS High Voltage Transitoris: Internal protection against voltage pics.
7.2 General Troubleshooting Steps
- Sense pantalla/Sense alimentació: Check battery connections and fuse. Ensure battery voltage is within the operating range (8V~68V).
- Sense càrrega: Check PV connections, ensure solar panels are receiving sunlight, and verify PV voltage is sufficient (above battery voltage). Check for PV short circuit or reverse polarity.
- Baix corrent de càrrega: Check PV array size, shading, and battery state of charge. Ensure battery type settings are correct.
- La càrrega no funciona: Check load connections, ensure battery voltage is above over-discharge protection, and verify load control settings.
8. Especificacions
| Paràmetre | Valor |
|---|---|
| Volum del sistematage | 12V / 24V / 36V / 48V DC Auto |
| Corrent de càrrega nominal | 80A |
| Màx. Potència d'entrada fotovoltaica | 1000 W (12 V), 2000 W (24 V), 3000 W (36 V), 4000 W (48 V) |
| Màx. Circuit obert PV Voltage | 150VDC |
| Selecció del tipus de bateria | Lead-acid (Gel, Sealed, AGM, Flooded) and User |
| Posada a terra | Common Negative Ground |
| Volum d'entrada de bateriatage Rang | 8V ~ 68V |
| Compensació de temperatura | -3mV/℃/2V (per defecte) |
| Mida de cable recomanada | 16 mm² (6AWG) |
| Dimensions (L x A x A) | 394 mm × 236 mm × 119 mm |
| Pes | 4.5 kg (9.92 lliures) |
| Comunicació | Isolated RS-485 (5VDC/200mA) with MODBUS protocol |
| Màx. Eficiència | 98.7% |
9. Garantia i assistència
EPEVER products are designed for reliability and performance. This product comes with a standard manufacturer's warranty against defects in materials and workmanship. Please refer to the warranty card included with your product or visit the official EPEVER weblloc web per obtenir informació detallada sobre els termes i condicions de la garantia.
For technical support, troubleshooting assistance, or warranty claims, please contact EPEVER customer service through their official website or the contact information provided in your product packaging. When contacting support, please have your product model number and purchase date available.
Weblloc: www.epever.com (Exampl'enllaç, l'enllaç real pot variar)