This user manual provides detailed instructions for the installation, operation, and maintenance of the Walfront MS-190 220V Red Continuous Sound 120DB Motor Wind Screw Alarm Electronic Security System. Please read this manual thoroughly before using the product to ensure safe and efficient operation.

Producte acabatview

The Walfront MS-190 is a robust motor-driven alarm designed for various security and signaling applications. It produces a continuous, loud sound of 120dB, making it suitable for factories, construction sites, and road fault devices.

Walfront MS-190 Motor Wind Screw Alarm

Figura 1: Frontal view of the Walfront MS-190 Motor Wind Screw Alarm, showcasing és vermell casing and sound vents.

Especificacions

AtributValor
Número de modelMS-190
Voltage220 V
Tipus de soContinuous Sound (Motor Wind Screw Type)
ColorVermell
Electricitat50 mA
Voice Size120 dB
Poder25W
PesAprox. 400 g (14.1 oz)
MaterialFerro
Dimensions del producte3.94 x 1.97 x 3.15 polzades

The MS-190 alarm is designed for durability and stable performance, featuring high and low temperature resistance.

Contingut del paquet

En obrir el paquet, comproveu que tots els components siguin presents i no estiguin danyats:

Informació de seguretat

To ensure safe operation and prevent damage to the device or injury to personnel, please observe the following safety precautions:

Configuració i instal·lació

The MS-190 alarm features a fixed base installation for easy mounting. Follow these steps for proper setup:

  1. Trieu una ubicació: Select a stable and secure mounting surface. Ensure the location allows for optimal sound propagation and is protected from direct impact or excessive vibration.
  2. Muntar la base: Use appropriate screws and anchors (not included) to securely fasten the alarm's fixed base to the chosen surface. The base allows for adjustment of the sound outlet (Tuyere) up and down.
  3. MS-190 alarm with fixed base installation

    Figure 2: The MS-190 alarm showing its fixed base installation, which allows for vertical adjustment of the sound outlet.

  4. Cablejat: Connect the two wires from the alarm unit to your 220V power source. Ensure correct polarity if specified, though for AC devices like this, polarity is often not critical. It is recommended to use a circuit breaker or fuse for protection.
  5. Video 1: A demonstration of handling the MS-190 alarm, showing its components and how the wires are connected. This video illustrates the physical aspects of the alarm and its wiring points.

  6. Connexions segures: Double-check all electrical connections to ensure they are secure and insulated to prevent short circuits.
  7. Comprovació final: Before applying power, visually inspect the installation to confirm everything is correctly mounted and wired.
posterior view of MS-190 alarm showing wiring

Figura 3: posterior view of the MS-190 alarm, highlighting the wiring entry point and mounting bracket.

Instruccions de funcionament

The Walfront MS-190 alarm is designed for straightforward operation:

  1. Encès: Once installed and wired correctly, apply 220V power to the alarm. The alarm will immediately begin to produce a continuous sound.
  2. Apagar: To stop the alarm, disconnect the 220V power supply.

The alarm is intended for applications requiring a continuous audible signal, such as emergency alerts, warning signals, or process completion indicators in industrial or commercial settings.

MS-190 alarm in an industrial setting

Figure 4: An illustration of the MS-190 alarm's potential application in an industrial environment, such as a factory or construction site.

Manteniment

The Walfront MS-190 alarm requires minimal maintenance to ensure long-term reliability:

Resolució de problemes

If you encounter issues with your MS-190 alarm, refer to the following table for common problems and solutions:

ProblemaCausa possibleSolució
L'alarma no sonaSense font d'alimentacióCheck power connection, circuit breaker, and ensure 220V supply.
Alarm sounds weak or intermittentVol insuficienttage o cablejat soltVerify 220V supply. Check all wiring connections for tightness and corrosion.
Sorolls o vibracions inusualsLoose mounting or internal component issueEnsure the alarm is securely mounted. If the issue persists, contact customer support.

Si el problema persisteix després d'intentar aquestes solucions, poseu-vos en contacte amb el servei d'atenció al client de Walfront per obtenir més ajuda.

Garantia i Suport

Walfront products are manufactured to high-quality standards. For information regarding warranty coverage, technical support, or replacement parts, please refer to the official Walfront weblloc web o poseu-vos en contacte amb el seu departament d'atenció al client. Conserveu el rebut de compra com a comprovant de compra per a reclamacions de garantia.

Per obtenir assistència directa, podeu visitar el Botiga Walfront a Amazon.

Documents relacionats - MS-190

Preview Manual d'usuari de l'eina de prova ScopeMeter Fluke 190 Sèrie III
Manual d'usuari complet per a les eines de prova ScopeMeter de la sèrie Fluke 190 III i l'analitzador d'accionaments de motor MDA-550-III, que cobreix el funcionament, les característiques, els mesuraments i la resolució de problemes per a sistemes elèctrics i electrònics industrials.
Preview Fire-Lite MS-9600LS/MS-9600UDLS Series Addressable Fire Alarm Control Panel Manual
This manual provides comprehensive guidance on the installation, operation, and programming of the Fire-Lite MS-9600LS, MS-9600LSE, MS-9600UDLS, MS-9600UDLSE, and MS-9600LSC addressable fire alarm control panels. It covers system setup, device configuration, operational procedures, and essential safety information.
Preview Motors submergibles Grundfos MS, MMS: Instruccions d'instal·lació i funcionament
Instruccions completes d'instal·lació i funcionament per als motors submergibles Grundfos MS i MMS, que abasten el lliurament, l'emmagatzematge, la descripció general, la preparació, la connexió elèctrica, la instal·lació, el manteniment, la detecció d'avaries i el dimensionament dels cables.
Preview Guia de l'usuari de minimarcadors sense fil integrats - Colorado Time Systems
Guia d'usuari per a minimarcadors sense fil integrats de Colorado Time Systems (sense fil de 2.4 GHz) per a esports d'equip. Cobreix el producte més deview, instal·lació, instruccions d'ús, substitució de bateries i estàndards tècnics per als models MS-0055 a MS-0080.
Preview Eines de prova ScopeMeter Fluke 190 Sèrie III: Oscil·loscopis d'alt rendiment per a entorns industrials
Exploreu les eines de prova ScopeMeter de la sèrie 190 III de Fluke, oscil·loscopis portàtils i robustos dissenyats per a entorns industrials durs. Descobriu característiques com ara s d'alta velocitatampling, memòria profunda, Connect-and-View™ activació, enregistrador TrendPlot™ i FlukeView™ programari per a la resolució de problemes i l'anàlisi eficients.
Preview Radio Station 190 (Ra 190) Technical Manual - Part II
Detailed technical manual for the Radio Station 190 (Ra 190), covering construction, function, service, and technical data. This manual is intended for service personnel and provides in-depth information on the transmitter, receiver, and associated components.