BFT ALENA SW 2 D113811 00004

BFT ALENA SW 2 Control Board Instruction Manual

Model: ALENA SW 2 (D113811 00004)

Marca: BFT

1. Introducció i informació de seguretat

The BFT ALENA SW 2 (D113811 00004) is a sophisticated control board designed for the automation of one or two 230V operators, specifically for swing gates and industrial folding doors. This unit features DIP switches and potentiometers for precise configuration and includes deceleration management for smooth operation.

Avís de seguretat important: This product is intended for professional use only. Installation and maintenance must be carried out by qualified and certified professional installers in accordance with local regulations (e.g., D.M. 37/2008 in Italy). Attempting "do-it-yourself" installation by private users without the necessary technical expertise can lead to potentially dangerous situations and will void the product warranty. The professional installer is responsible for issuing a fiscal document confirming the correct installation of the BFT product.

BFT ALENA SW 2 Control Board inside its white protective casing, showing the green circuit board with various electronic components, terminals, DIP switches, and potentiometers.

Figure 1: BFT ALENA SW 2 Control Board. This image displays the internal components of the control board, including the main circuit board, transformer, various colored terminal blocks for connections, and configuration elements like DIP switches and potentiometers, all housed within a durable white enclosure.

2. Configuració i instal·lació

Installation of the BFT ALENA SW 2 control board requires specialized knowledge and adherence to electrical safety standards. It must be performed exclusively by a professional installer.

2.1 Comprovacions prèvies a la instal·lació

  • Ensure the power supply is disconnected before commencing any work.
  • Verify that the gate or door operators are compatible with a 230V power supply and the control board's power output (400+400W).
  • Confirm all necessary safety devices (photocells, safety edges) are present and functional.

2.2 Mounting the Control Board

Mount the control board in a secure, weather-protected enclosure, away from direct sunlight and moisture. Ensure adequate ventilation if required. Use appropriate fasteners to secure the unit firmly.

2.3 Connexions elèctriques

Refer to the wiring diagram provided with the product packaging for detailed connection instructions. Key connections typically include:

  • Font d'alimentació principal: Connect the 230V AC power supply to the designated terminals.
  • Connexions del motor: Connect the gate/door operators to the motor output terminals.
  • Dispositius de seguretat: Connect photocells, safety edges, and emergency stop buttons to their respective safety input terminals.
  • Command Devices: Connect push buttons, remote control receivers, and key switches to the command input terminals.
  • Accessoris: Connect flashing lights, courtesy lights, and other accessories as per the diagram.

All wiring must comply with local electrical codes and standards. Use appropriate cable gauges for all connections.

3. Instruccions de funcionament

Once installed and powered, the ALENA SW 2 control board can be configured and operated. Configuration is primarily done via DIP switches and potentiometers.

3.1 Initial Power-Up and Self-Learning

Upon first power-up, the control board may initiate a self-learning cycle to determine the gate/door travel limits and force. Follow the specific procedure outlined in the detailed product manual (not provided here) for this process.

3.2 Configuration via DIP Switches and Potentiometers

The control board features a set of DIP switches and potentiometers to adjust various operating parameters, including:

  • Lògica de funcionament: Automatic, semi-automatic, step-by-step.
  • Motor Force/Power: Adjustment of motor power for opening and closing.
  • Deceleration Speed: Setting the speed reduction at the end of travel.
  • Temps de pausa: Duration before automatic closing (if enabled).
  • Safety Input Configuration: Normally Open (NO) or Normally Closed (NC) for safety devices.

Consult the comprehensive technical manual for the exact function of each DIP switch and potentiometer setting. Incorrect settings can affect performance and safety.

3.3 Funcionament bàsic

Once configured, the gate/door can be operated using connected command devices (e.g., remote control, push button). A single command typically cycles through Open-Stop-Close-Stop.

4. Manteniment

Regular maintenance by a qualified professional is essential to ensure the longevity and safe operation of the BFT ALENA SW 2 control board and the automated system.

4.1 Routine Checks (Professional Only)

  • Inspecció visual: Check for any signs of damage, corrosion, or loose connections on the control board and wiring.
  • Estanquitat del terminal: Ensure all terminal screws are securely tightened.
  • Dispositius de seguretat: Test the functionality of all connected safety devices (photocells, safety edges, emergency stops) regularly.
  • Funcionament del motor: Observe the smooth operation of the gate/door, checking for unusual noises or jerky movements.
  • Desacceleració: Verify that the deceleration function is working correctly at the end of travel.

4.2 Neteja

Ensure the control board and its enclosure are kept clean and free from dust, debris, and insects. Use a soft, dry brush or compressed air for cleaning. Do not use liquid cleaners directly on the electronic components.

Nota: Always disconnect power to the control board before performing any maintenance or cleaning.

5. Solució De Problemes

This section provides general guidance for common issues. For detailed diagnostics and repair, always consult a qualified professional.

ProblemaCausa possibleSolution (Professional Action)
Gate/Door does not move.No power, faulty motor, safety device activated, remote control battery low.Check power supply, inspect motor connections, verify safety device status, replace remote battery.
Gate/Door stops unexpectedly.Obstruction detected, safety device triggered, motor overheating.Remove obstruction, check safety device alignment/function, allow motor to cool.
Gate/Door opens but does not close.Safety device issue (e.g., photocells blocked), closing limit switch fault.Clean/align photocells, inspect limit switch wiring/function.
Irregular operation or erratic behavior.Incorrect DIP switch settings, loose connections, interference.Review DIP switch settings against manual, check all wiring connections, investigate sources of electrical interference.

If the problem persists after basic checks, contact a qualified BFT service technician or the professional installer.

6. Especificacions

The following are the key technical specifications for the BFT ALENA SW 2 control board:

  • Model: ALENA SW 2
  • Número de peça: D113811 00004
  • Aplicació: Control board for one or two operators
  • Compatibilitat: Designed for swing gates and industrial folding doors
  • Entrada Voltage: 230 V AC
  • Potència de sortida del motor: 400W + 400W (total 800W)
  • Configuració: DIP switches and potentiometers
  • Característiques: Deceleration management
  • Fabricant: BFT

7. Garantia i Suport

The warranty for BFT products is subject to specific conditions, primarily requiring professional installation. As stated in the legal information provided by the seller (Matic Line), the warranty is valid only if the product is installed by a qualified professional installer who issues a fiscal document confirming the installation.

Private users who purchase this product and do not arrange for professional installation may not be able to avail themselves of the warranty, especially in cases of potentially dangerous situations arising from improper installation due to a lack of technical competence.

For technical support, warranty claims, or professional installation services, please contact your certified BFT installer or the authorized distributor from whom the product was purchased. Matic Line, as the seller, ensures all products are new, sealed in original packaging, and undergo thorough inspection before shipment.

Documents relacionats - ALENA SW 2 D113811 00004

Preview Manual d'instal·lació del panell de control BFT ALENA SW2 CPEM
Manual d'instal·lació complet per al panell de control BFT ALENA SW2 CPEM, que cobreix la configuració, el cablejat, la programació i les funcions de seguretat per a sistemes de portes automatitzades.
Preview Guia de referència ràpida del kit UL de BFT Phobos BT
Guia de referència ràpida per al sistema d'obridor de portes automàtic BFT Phobos BT Kit UL, que cobreix la instal·lació, el cablejat, la programació i la resolució de problemes.
Preview Manual d'instal·lació i ús de l'operador de porta BFT DEIMOS BT B 400/600
Aquest manual proporciona instruccions completes per a la instal·lació, el cablejat, la configuració i el funcionament dels sistemes d'operació de portes automàtiques BFT DEIMOS BT B 400 i DEIMOS BT B 600.
Preview Manual d'instal·lació de l'automatització de portes batents BFT VIRGO
Guia completa d'instal·lació i ús del sistema d'automatització de portes batents BFT VIRGO, que cobreix la seguretat, les especificacions tècniques, els procediments d'instal·lació, la programació i el manteniment.
Preview Manual d'instal·lació de l'automatització de pistons BFT GIUNO ULTRA BT A20 / GIUNO ULTRA BT A50
Manual d'instal·lació complet per a les automatitzacions de pistó hidràulic BFT GIUNO ULTRA BT A20 i GIUNO ULTRA BT A50 per a portes batents. Cobreix les especificacions tècniques, el muntatge, el cablejat, els ajustos i les precaucions de seguretat.
Preview Instruccions de codificació del comandament a distància BFT Mitto 2M/4M: una guia completa
Apreneu a programar els vostres comandaments a distància BFT Mitto 2M i 4M per a obridors de garatges i portes. Aquesta guia tracta la codificació per a receptors amb i sense pantalles digitals, incloent-hi importants avisos de seguretat.