1. Introducció
This manual provides essential instructions for the installation, operation, and maintenance of your FSP iFP600 Uninterruptible Power Supply (UPS). Please read this manual thoroughly before installing or operating the unit to ensure proper function and safety. The FSP iFP600 is designed to provide reliable power backup and surge protection for your electronic devices.

Imatge 1.1: Frontal view of the FSP iFP600 UPS, showcasinpel seu disseny compacte i la pantalla LCD integrada.
2. Instruccions de seguretat
Please adhere to these important safety guidelines during installation, operation, and maintenance of the UPS:
- No obriu el SAI casing. No hi ha peces a l'interior que l'usuari pugui reparar. Demaneu totes les tasques de manteniment a personal de servei qualificat.
- Do not connect appliances that could overload the UPS, such as laser printers, vacuum cleaners, or heaters.
- Assegureu-vos que el SAI estigui connectat a una presa de corrent de CA amb connexió a terra.
- Avoid placing the UPS in direct sunlight, near heat sources, or in environments with excessive dust, humidity, or corrosive substances.
- Position the UPS in a well-ventilated area to prevent overheating.
- In case of fire, use a dry chemical extinguisher. Water can be hazardous.
- The battery inside the UPS is not user-replaceable. Battery replacement should only be performed by qualified personnel.
3. Producte acabatview
The FSP iFP600 UPS provides reliable power protection for your critical electronics. It features a compact design and an intuitive LCD display for monitoring status.
3.1 Contingut del paquet
En obrir el paquet, comproveu que tots els components siguin presents i no estiguin danyats:
- FSP iFP600 UPS Unit
- Manual d'usuari (aquest document)
- Cable d'alimentació
- Cable de comunicació USB

Image 3.1: The FSP iFP600 UPS shown alongside its retail packaging, illustrating the product's presentation.
3.2 Components del panell posterior
Familiarize yourself with the connections on the rear panel of the UPS:

Imatge 3.2: Detallada view of the FSP iFP600 UPS rear panel, highlighting connection points.
- Punts de venda: Two SCHUKO type outlets for connecting protected equipment.
- Entrada de CA: Connects the UPS to the main utility power.
- Fuse/Breaker: Overcurrent protection for the UPS.
- Comunicació USB: Port for connecting to a computer for monitoring and management.
- Combo RJ11/RJ45 Surge Protection: Provides surge protection for telephone/network lines.
4. Configuració i instal·lació
Follow these steps to set up your FSP iFP600 UPS:
- Desembalatge: Traieu amb cura el SAI del seu embalatge. Inspeccioneu-lo per detectar qualsevol dany durant l'enviament.
- Col·locació: Place the UPS on a flat, stable surface in a clean, cool, and well-ventilated area. Ensure adequate clearance around the unit for airflow.
- Càrrega inicial: Connect the UPS to a standard grounded AC outlet using the provided power cord. Allow the unit to charge for at least 4-6 hours before initial use to ensure optimal battery performance. The UPS will charge whether it is turned on or off.
- Equip de connexió: Plug your computer, monitor, and other critical electronic devices into the UPS outlets (A). Do not connect surge suppressors or power strips to the UPS outlets.
- Comunicació USB (opcional): Connect the USB cable from the UPS USB port (D) to your computer's USB port to enable power management software features (software not included, typically downloaded from manufacturer's weblloc).
- RJ11/RJ45 Protection (Optional): For surge protection of your telephone or network line, connect the incoming line to the 'IN' port of the Combo RJ11/RJ45 (E) and connect the 'OUT' port to your device.
5. Instruccions de funcionament
5.1 Engegada/apagada
- Per encendre: Press and hold the power button on the front panel for approximately 2 seconds until you hear a beep and the LCD display illuminates.
- Per apagar: Press and hold the power button for approximately 2 seconds until you hear a beep and the LCD display turns off.
5.2 Informació de la pantalla LCD
The FSP iFP600 features an LCD display that provides real-time status information. The display is touch-sensitive for navigating information.

Image 5.1: The LCD display of the FSP iFP600 UPS, indicating voltage output and its touch-screen functionality.
The LCD display typically shows:
- Entrada Voltage
- Vol. De sortidatage
- Nivell de càrrega de la bateria
- Nivell de càrrega
- Operating Mode (e.g., AC mode, Battery mode)
- Warning/Fault Indicators
5.3 Funcionament en mode bateria
When the utility power fails or fluctuates outside acceptable limits, the UPS will automatically switch to battery mode. During battery mode, the UPS will provide power to connected equipment from its internal battery. An audible alarm will sound to indicate battery operation.
6. Manteniment
Proper maintenance ensures the longevity and reliability of your UPS.
- Neteja: Use a soft, dry cloth to clean the exterior of the UPS. Do not use liquid or aerosol cleaners.
- Cura de la bateria: To maximize battery life, ensure the UPS is connected to AC power and fully charged. If the UPS is stored for an extended period, recharge it every three months to prevent battery degradation.
- Substitució de la bateria: The internal battery (12V / 7Ah x1) is not user-serviceable. Battery replacement should only be performed by FSP-certified service personnel or a qualified technician. Incorrect battery replacement can pose a risk of explosion or injury.
- Emmagatzematge: Store the UPS in a cool, dry place with adequate ventilation. Ensure the battery is fully charged before storage.
7. Solució De Problemes
Refer to the following table for common issues and their solutions. If the problem persists, contact FSP support.
| Símptoma | Alarma sonora | Causa possible | Solució |
|---|---|---|---|
| UPS operating on battery power | Emet un so cada 10 segons | Utility power failure or fluctuation | Save work and shut down equipment if power outage is prolonged. UPS will return to AC mode when power is restored. |
| Avís de bateria baixa | Sona cada segon | La càrrega de la bateria és críticament baixa | Immediately save work and shut down connected equipment. |
| Condició de sobrecàrrega | Sona cada 0.5 segon | Connected equipment exceeds UPS capacity | Disconnect non-essential equipment until the alarm stops. Ensure total load is within UPS capacity. |
| Falla del SAI | Sonant contínuament | Falla interna o mal funcionament | Turn off the UPS and disconnect it from the AC outlet. Contact FSP technical support. |

Image 7.1: Excerpt from the FSP iFP series specification table, detailing alarm indicators and their meanings.
8. Especificacions
Detailed technical specifications for the FSP iFP600 UPS:
| Característica | Especificació |
|---|---|
| Model | iFP 600 |
| Capacitat | 600 VA / 360 W |
| Entrada Voltage | 110/120 Vac or 220/230/240 Vac |
| Entrada Voltage Rang | 81-145 Vac / 140-290 Vac |
| Interval de freqüència d'entrada | 60/50 Hz (detecció automàtica) |
| Vol. De sortidatage | 110/120 Vac or 220/230/240 Vac |
| Vol. ACtage Regulació (mode Bat.) | ±10% |
| Output Frequency Range (Batt. Mode) | 60 Hz or 50 Hz ±1 Hz |
| Temps de transferència | Típica 2-6 ms |
| Forma d'ona (mode Batt.) | Onda sinusoïdal simulada |
| Tipus i número de bateria | 12V / 7Ah x1 |
| Temps de recàrrega típic | 4 hores fins al 90% de capacitat |
| Indicadors | LCD Display (Touch panel with digital information) |
| Protecció | Overload, Discharge, and Overcharge Protection |
| Pes de l'article | 9.24 lliures (4.2 kg) |
| Dimensions del producte (LxWxH) | 11.81 x 3.98 x 5.59 polzades |
| Color | Negre |
| Material | Metall |
9. Garantia i Suport
FSP products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or visit the official FSP website. For technical support, troubleshooting assistance, or service inquiries, please contact FSP customer service through their official channels.
Podeu trobar més informació i recursos de suport a FSP Store on Amazon.