Risco RWX73M

Risco RWX73M Wireless Bidirectional Door/Window Opening Detector

Manual d'usuari

Model: RWX73M | Brand: Risco

1. Introducció

The Risco RWX73M is a wireless bidirectional opening detector designed for monitoring doors and windows. It provides reliable security by detecting unauthorized opening and communicating with a compatible Risco alarm system, such as the Agility series. Its bidirectional communication ensures enhanced security and system integrity.

2. Informació de seguretat

  • Llegiu atentament totes les instruccions abans de la instal·lació i el funcionament.
  • No intenteu desmuntar ni reparar el dispositiu. Encarregueu tot el manteniment a personal qualificat.
  • Manteniu el dispositiu allunyat de l'aigua, la humitat i les temperatures extremes.
  • Ensure proper disposal of the device and any internal batteries according to local regulations.
  • This device is part of a security system; ensure the entire system is installed and maintained correctly for optimal performance.

3. Contingut del paquet

Si us plau, comproveu el paquet per veure si hi ha els elements següents:

  • Risco RWX73M Contact Unit
  • Unitat magnètica
  • Mounting Screws/Adhesive (may vary by package)
  • Quick Start Guide (this manual provides detailed information)

4. Configuració i instal·lació

The RWX73M consists of two main parts: the contact unit and the magnet unit. For proper operation, these two parts must be installed in close proximity to each other on a door or window frame.

Risco RWX73M Wireless Door/Window Opening Detector

Image: The Risco RWX73M wireless door/window opening detector, showing the main contact unit and the smaller magnet unit.

4.1. Triar una ubicació

Install the detector on the frame of the door or window you wish to monitor. The contact unit should be mounted on the stationary part (frame), and the magnet unit on the moving part (door/window). Ensure the two units are aligned and within 1 cm of each other when the door/window is closed.

4.2. Mounting the Units

  1. Prepara la superfície: Clean the mounting surface thoroughly to ensure good adhesion if using adhesive, or to mark screw holes accurately.
  2. Mount the Contact Unit: Secure the larger contact unit to the door/window frame using the provided screws or adhesive strips.
  3. Mount the Magnet Unit: Secure the smaller magnet unit to the door or window itself, ensuring it aligns with the marked area on the contact unit when the door/window is closed. The gap between the two units should be minimal (ideally less than 1 cm).
  4. Alineació de prova: Close the door/window and verify that the contact and magnet units are perfectly aligned.

4.3. Pairing with Risco Agility System

The RWX73M must be enrolled into your Risco Agility alarm system. Refer to your Risco Agility system's installation manual for detailed instructions on enrolling wireless detectors. Generally, this involves:

  • Putting the Agility panel into enrollment mode.
  • Activating the RWX73M (e.g., by opening and closing the door/window, or pressing a tampinterruptor si n'hi ha).
  • Confirming successful enrollment on the panel.

Ensure the detector is assigned to the correct zone and configured with appropriate attributes (e.g., entry/exit, perimeter).

5. Funcionament

Once installed and successfully paired with your Risco Agility system, the RWX73M operates automatically:

  • When the door or window is tancat, the contact unit and magnet unit are in close proximity, indicating a secure state.
  • When the door or window is obert, the magnet unit moves away from the contact unit. The RWX73M detects this separation and immediately transmits a signal to the Risco Agility alarm panel.
  • The alarm panel then processes this signal according to its programming (e.g., triggers an alarm if the system is armed, logs the event).
  • The bidirectional communication allows the panel to monitor the detector's status, including battery life and supervision signals.

6. Manteniment

The Risco RWX73M is designed for low maintenance. However, periodic checks are recommended:

  • Neteja: Gently wipe the exterior of the units with a soft, dry cloth to remove dust or dirt. Do not use abrasive cleaners or solvents.
  • Estat de la bateria: The device is designed with an internal, long-life battery. Your Risco Agility alarm panel will typically indicate a low battery condition for the detector. When a low battery signal is received, contact your alarm system installer or Risco support for service, as the battery is generally not user-replaceable.
  • Prova de funcionalitat: Periodically test the detector by arming your system and opening the monitored door/window to ensure it triggers the alarm as expected.

7. Solució De Problemes

Problema Causa possible Solució
Detector not responding / No alarm when opened
  • Not properly enrolled with the panel.
  • Incorrect alignment of contact and magnet units.
  • Low or depleted internal battery.
  • Out of range from the alarm panel.
  • Re-enroll the detector with the Risco Agility panel.
  • Adjust the position of the units for proper alignment (gap < 1 cm).
  • Check panel for low battery indication; contact service if needed.
  • Relocate the detector closer to the panel or consider a wireless repeater.
Falses alarmes
  • Muntatge fluix.
  • Vibrations causing temporary separation.
  • Interferència ambiental.
  • Ensure units are securely mounted.
  • Check for structural issues causing movement.
  • Consult with your installer to diagnose potential interference.
Panel indicates communication loss with detector
  • Detector is out of range.
  • Interferència de ràdio.
  • Internal battery issue.
  • Relocate the detector or panel.
  • Identificar i mitigar les fonts d'interferència.
  • Contact service for battery check/replacement.

8. Especificacions

Característica Detall
Fabricant Risco
Número de part RWX73M
Pes de l'article 81.65 g
Model Number (Item) 1
Piles incloses? No (refers to user-replaceable; device has internal battery)
Necessites piles? No (refers to user-replaceable; device has internal battery)
ASIN B07R287PS5
Actualitzacions de programari garantides fins Desconegut
Primera data disponible 27 de desembre de 2019
Gama exterior Fins a 300 m
Contact Unit Dimensions (H x W x D) 72 x 35 x 32 mm
Magnet Unit Dimensions (H x W x D) 72 x 11 x 16 mm
Compatibilitat Risco Agility systems

9. Garantia i Suport

For warranty information and technical support regarding your Risco RWX73M detector, please refer to the documentation provided with your complete Risco alarm system or visit the official Risco website. It is recommended to contact your authorized Risco installer or dealer for any service or support needs.

You can typically find support resources, FAQs, and contact information on the official Risco weblloc: www.riscogroup.com

Documents relacionats - RWX73M

Preview LuNAR 150DTG3 Ceiling Motion Detector Installation and Technical Guide
Comprehensive guide for the RISCO LuNAR 150DTG3 ceiling motion detector, covering installation, maintenance, technical specifications, jumper settings, terminal wiring, LED indicators, and warranty information.
Preview RISCO iWISE RK815DTGL/RK825DTGL Motion Detector Installation and Technical Specifications
Comprehensive guide to the RISCO iWISE RK815DTGL and RK825DTGL motion detectors, covering installation, jumper settings, technical specifications, features like ACT™ and Green Line, and warranty information.
Preview LightSYS Plus User Manual by RISCO: Comprehensive Security System Guide
This user manual provides detailed instructions for the RISCO LightSYS Plus, an advanced security system for residential and commercial use. Learn about its flexible, scalable, hybrid features, cloud connectivity, remote operation, and setup procedures.
Preview RISCO RWS332 Wireless 2-Way Indoor Sounder: Installation and User Guide
This document provides installation, configuration, and user information for the RISCO RWS332 Wireless 2-Way Indoor Sounder. It covers features, setup procedures, technical specifications, and warranty details.
Preview RISCO WL Panda Keypad for LightSYS Air/LightSYS Plus: Installation and User Guide
Comprehensive installation and user guide for the RISCO WL Panda 2-Way Wireless Keypad (Models RW432KPP2, RW432KPP402A, RW432KPP802A) for LightSYS Air and LightSYS Plus alarm systems. Features, setup, operation, technical specifications, and warranty information.
Preview RISCO RK66S Seismic Detector Installation Instructions
Comprehensive installation guide for the RISCO RK66S Seismic Detector, detailing features, mounting procedures, wiring, dipswitch settings, and testing for both Stand Alone and BUS modes.