Akicon 1424-ORB

Manual d'usuari del ventilador d'extracció de bany Akicon 1424-ORB amb llum i llum nocturna

Model: 1424-ORB

1. Introducció

This manual provides detailed instructions for the safe installation, operation, and maintenance of your Akicon 1424-ORB Bathroom Exhaust Fan with Light and Nightlight. Please read all instructions carefully before beginning installation or use. Retain this manual for future reference.

The Akicon 1424-ORB is an ultra-quiet ventilation solution designed to effectively remove moisture and odors from your bathroom. It features a powerful 110 CFM fan, an integrated main light, and a nightlight, all within a durable oil rubbed bronze finish.

2. Informació de seguretat

WARNING: RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS.

  • Installation must be performed by a qualified electrician in accordance with all applicable local codes and standards, including fire-rated construction codes and standards.
  • Always disconnect power at the service panel before wiring or servicing this unit. Lock out the service panel to prevent accidental power-on.
  • This unit is designed for general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
  • To prevent motor damage and noisy/unbalanced impellers, keep drywall spray, construction dust, etc., off the power unit.
  • Duct work must be installed with a minimum of 4-inch diameter to ensure proper airflow.
  • Assegureu-vos que el ventilador estigui correctament connectat a terra.
  • Do not install this fan in a cooking area.

3. Contingut del paquet

Verifiqueu que tots els components siguin presents abans de començar la instal·lació:

  • Ventilador
  • Reixa
  • Coberta de llum
  • 12-inch Suspension Bracket
  • 14-inch Extension Bracket
  • Cargols de muntatge
  • Grille and Cover Mounting Hardware
  • LED Bulb (Main Light)
  • Bombeta nocturna

4. Especificacions

MarcaAkicon
Nom del model1424-ORB
ColorBronze fregat amb oli
Flux d'aire110 CFM
Sone Rating1.5 sons
Mida recomanada de l'habitacióFins a 99 peus quadrats
Dimensions de la carcassa (L x A x A)9" x 9" x 7-11/16"
Light Cover Diameter15-5/16"
Mida del conducte4 polzades
Llum principal3 x 9W GU24 Dimmable LED Bulbs (3000K / 5000K)
Llum nocturna1 x 4W E12 Bulb
MaterialMetal, Plastic, Glass Cover
Tipus de motorCopper Ball-Bearing Motor
CertificacionsHVI-certified, cUL listed (for over-showers and tubs with GFCI)

5. Instruccions d'instal·lació

Proper installation is crucial for the performance and longevity of your exhaust fan. It is recommended that installation be performed by a qualified professional.

5.1 Consideracions prèvies a la instal·lació

  • Accés: This fan is designed for installation in locations with attic access or during new construction. Replacing an existing fan may require modifications to the ceiling opening.
  • Mida d'obertura: The housing dimensions are 9 inches by 9 inches by 7-11/16 inches. Ensure your ceiling opening is appropriately sized. If replacing an older fan, you may need to enlarge the opening.
  • Conductes: Use 4-inch diameter ducting for optimal performance. Ensure duct runs are as short and straight as possible.
  • Mida de l'habitació: The fan is suitable for rooms up to 99 square feet. To calculate the minimum CFM needed for your bathroom, multiply the room's width, length, and height (in feet) by 0.13.
Installation Notice with Housing Dimensions
Image 1: Installation notice showing the fan housing dimensions (9" x 9" x 7.7") and emphasizing the importance of checking the opening size for replacement installations.
Product Parameter and Dimensions
Image 2: Detailed product parameters including airflow, sone rating, room size, and physical dimensions of the fan housing and light cover.
Attic and Soffit Installation Diagram
Image 3: Diagram illustrating typical installation scenarios, including attic and soffit access for ventilation.
Mesurament per a la instal·lació
Image 4: Visual guide on how to measure the existing opening and soffit/attic height for proper fan placement.
CFM Calculation Guide
Image 5: Instructions on how to calculate the minimum CFM required for your bathroom based on its dimensions.

5.2 Mounting the Housing

  1. Position the fan housing between ceiling joists. Use the provided 12-inch or 14-inch suspension/extension brackets to secure the housing to the joists.
  2. Ensure the housing is level and securely fastened to prevent vibration and noise.
  3. Connect the 4-inch ductwork to the fan's exhaust collar. Seal all duct connections with duct tape or clamps to prevent air leakage.

5.3 Cablejat

The fan, main light, and nightlight can be wired jointly or separately to wall switches, depending on your preference and existing wiring. Consult a qualified electrician if you are unsure about wiring procedures.

  1. Route electrical supply wires to the fan housing's junction box.
  2. Remove the junction box cover and connect the wires according to the wiring diagram provided inside the junction box cover and local electrical codes. Ensure proper grounding.
  3. Assegureu totes les connexions de cables amb connectors de cable homologats.
  4. Substituïu la coberta de la caixa de connexió.

5.4 Finalització de la instal·lació

  1. Install the provided LED bulb for the main light and the E12 bulb for the nightlight into their respective sockets.
  2. Attach the light cover to the fan housing using the provided hardware.
  3. Secure the grille to the housing.
  4. Restore power at the service panel and test the fan, main light, and nightlight functions.
Fan Components and Features
Imatge 6: Primer pla views detailing the light cover, fan housing, and the copper ball-bearing motor, highlighting the quality construction and components.

6. Instruccions de funcionament

The Akicon 1424-ORB fan operates via standard wall switches. Depending on your wiring configuration, you may have separate switches for the fan, main light, and nightlight, or a single switch controlling multiple functions.

  • Funcionament del ventilador: Activate the fan by flipping the designated wall switch. The fan will begin to exhaust air from the room.
  • Funcionament de la llum principal: Turn on the main LED light using its dedicated wall switch. The main light provides ample illumination for your bathroom.
  • Nightlight Operation: Activate the nightlight with its separate wall switch. The nightlight offers a soft glow for low-light conditions.
  • Característica regulable: The main LED bulbs are dimmable. If connected to a compatible dimmer switch (not included), you can adjust the brightness. The color temperature can be set to 3000K (warm light) or 5000K (bright light) as per the bulb's specifications.

7. Manteniment

Regular cleaning and maintenance will ensure optimal performance and extend the life of your exhaust fan.

7.1 Cleaning the Grille and Light Cover

  1. Desconnecteu l'alimentació: Always turn off power at the service panel before cleaning.
  2. Eliminar components: Carefully remove the light cover and grille from the fan housing.
  3. Neteja: Wash the grille and light cover with a mild detergent and warm water. Rinse thoroughly and allow them to dry completely before reinstallation.
  4. Torneu a instal·lar: Reattach the light cover and grille to the fan housing.

7.2 Cleaning the Fan Interior

  1. Desconnecteu l'alimentació: Ensure power is off at the service panel.
  2. Access Fan: Remove the grille and light cover.
  3. Neteja de les aspes del ventilador: Use a soft cloth or brush to gently clean dust and debris from the fan blades and motor housing. Avoid using harsh chemicals or abrasive cleaners.
  4. Torneu a muntar: Once clean and dry, reassemble the light cover and grille.
  5. Restaura l'alimentació: Turn power back on at the service panel.

8. Solució De Problemes

If you experience issues with your Akicon exhaust fan, refer to the following common problems and solutions:

ProblemaCausa possibleSolució
El ventilador no funcionaNo power supply; Loose wiring; Faulty switch; Motor failure.Check circuit breaker/fuse. Verify all wire connections. Test switch. If motor failure is suspected, contact customer support.
La llum no s'encénNo power supply; Loose wiring; Burnt-out bulb; Faulty switch.Check circuit breaker/fuse. Verify wire connections. Replace bulb. Test switch.
Excés de soroll o vibracióLoose mounting; Debris in fan blades; Damaged motor/impeller; Improper ducting.Ensure housing is securely mounted. Clean fan blades. Check ductwork for obstructions or kinks. If noise persists, contact customer support.
Mal rendiment de ventilacióBlocked ductwork; Undersized fan for room; Excessive duct length/bends.Check ductwork for obstructions. Ensure ducting is 4-inch diameter. Review room size vs. fan CFM.

If troubleshooting steps do not resolve the issue, please contact Akicon customer support for assistance.

9. Garantia i Suport

The Akicon 1424-ORB Bathroom Exhaust Fan with Light and Nightlight is covered by a Garantia limitada de 3 anys des de la data de compra. Aquesta garantia cobreix els defectes de materials i de mà d'obra en ús normal.

For warranty claims, technical support, or any questions regarding your product, please contact Akicon customer service. Keep your proof of purchase for warranty validation.

For more information or to contact support, please visit the official Akicon weblloc web o consulteu la informació de contacte que us proporcioneu amb la documentació de compra.

Documents relacionats - 1424-ORB

Preview Extractor de bany AKICON de 110 CFM amb LED RGB, sensor d'humitat, 3CCT i llum nocturna: guia d'ús i cura
Guia completa d'ús i cura del ventilador de bany AKICON 110 CFM, amb mode LED RGB, sensor d'humitat, 3CCT i llum nocturna. Inclou instruccions d'instal·lació per a construccions noves i existents, resolució de problemes i manteniment.
Preview Guia d'ús i cura del ventilador d'extracció de bany AKICON 110 CFM amb LED RGB i sensor d'humitat
Guia detallada d'ús i cura del ventilador d'extracció de bany AKICON de 110 CFM. Cobreix la instal·lació (construcció nova i existent), les especificacions, la informació de seguretat, el manteniment, la resolució de problemes i el funcionament remot dels models AKHR110-RGB2-W, AKHR110-RGB2-B i AKHR110-RGB2-S.
Preview Extractor de bany AKICON de 110 CFM amb LED RGB, sensor d'humitat, 3CCT i llum nocturna: guia d'ús i cura
Guia completa d'ús i cura del ventilador de bany AKICON 110 CFM, amb mode LED RGB, sensor d'humitat, temperatura de color 3CCT i llum nocturna. Inclou instruccions d'instal·lació, informació de seguretat, resolució de problemes i detalls de la garantia.
Preview Ventilador de bany AKICON BPT14-80CL amb llum Guia d'ús i cura
Guia completa d'ús i cura del ventilador de bany amb llum AKICON BPT14-80CL, que detalla les especificacions del producte, la instal·lació, el manteniment, la resolució de problemes i la informació sobre la garantia.
Preview AKICON AK1390N2-W/B/S Ventilador de bany amb llum Guia d'ús i cura
Guia completa d'ús i cura del ventilador de bany AKICON AK1390N2-W/B/S amb llum LED. Inclou instruccions d'instal·lació, informació de seguretat, manteniment, resolució de problemes i detalls de la garantia.
Preview Guia de l'usuari de l'interruptor d'humitat AK-SW-FLHT
Guia d'usuari per a l'interruptor d'humitat AKICON AK-SW-FLHT, que detalla les especificacions, la configuració, els modes de funcionament i les instruccions de cablejat per controlar els ventiladors i els llums en funció dels nivells d'humitat.