1. Introducció
The Walfront G3/8 Pressure Sensor is a high-precision device designed for accurate pressure measurement in various industrial and commercial applications. Featuring a robust stainless steel casing, advanced ceramic core, and customized processing chip, this sensor offers stable performance, high accuracy, and a long service life. It is equipped with IP65 protection and provides an analog signal output, making it suitable for integration into diverse monitoring systems.
This manual provides essential information for the proper installation, operation, and maintenance of your Walfront pressure sensor. Please read it thoroughly before use to ensure optimal performance and safety.
2. Característiques
- Alta precisió: Designed for precise pressure measurement.
- Construcció duradora: Acer inoxidable casing with an advanced ceramic core.
- Compacte i lleuger: Small size and light weight for easy installation.
- Rendiment estable: Ensures long-term low drift and extended operational life.
- Protecció EMC: Enhanced stability and reliability.
- Protecció IP65: Provides resistance against dust and water ingress.
- Analog Signal Output: Compatible with standard control systems.
- G3/8 Screw Connection: Standardized connection for easy integration.
3. Especificacions
| Paràmetre | Valor |
|---|---|
| Classe de protecció | IP65 |
| Entrada Voltage | 5 ± 0.25 VDC / 5~32 VDC |
| Tecnologia | Piezoresistance |
| Connexió de cargol | G3/8 |
| Senyal de sortida | Senyal analògic |
| Interval de mesura | 0-5 BAR (Current Model) |
| Pressió de sobrecàrrega | 2 times full pressure |
| Blast Pressure | 3 times full pressure range |
| Accuracy (Non-linearity + Repeatability + Hysteresis) | ± 1% FS (0 ~ 80 °C) ± 1.5% FS (-20 ~ 100 °C) ± 3% FS (-40 ~ 125 °C) |
| Connexió elèctrica | Packard connector (three-core) |
| Material | Acer inoxidable |
| Color | Plata |
| UPC | 765613925002 |
4. Configuració
4.1 Instal·lació física
- Preparació: Ensure the system where the sensor will be installed is depressurized and free of contaminants.
- Lloc de muntatge: Select a mounting point that is representative of the pressure to be measured and easily accessible for maintenance. Avoid locations with excessive vibration or extreme temperatures beyond the sensor's operating range.
- Connexió: Carefully screw the G3/8 threaded end of the sensor into the corresponding port. Use appropriate sealing tape or compound if necessary to ensure a leak-free connection. Do not overtighten, as this can damage the sensor or the port.
- Orientació: The sensor can generally be installed in any orientation, but ensure the cable is not strained or exposed to sharp edges.

Figura 1: Primer pla view of the G3/8 screw terminal for physical connection.

Figura 2: General view of the Walfront pressure sensor.
4.2 Connexió elèctrica
The sensor uses a three-wire electrical connection, typically compatible with Packard connectors. Refer to the wiring diagram below for correct connections.
- Font d'alimentació: Connect the positive power supply (5 ± 0.25 VDC or 5~32 VDC) to the designated positive terminal (Pin 1, typically Red wire).
- Common/Ground: Connect the common end (Pin 3, typically Black wire) to the system ground.
- Sortida del senyal: Connect the analog signal output (Pin 2, typically Blue/Green wire) to your measurement or control equipment. The output signal range is typically 0.5V to 4.5V for the 0-5 BAR range.

Figure 3: Electrical wiring diagram for the pressure sensor.
Important: Assegureu-vos que la font d'alimentació voltage is within the specified range to prevent damage to the sensor. Incorrect wiring can lead to malfunction or permanent damage.
5. Instruccions de funcionament
5.1 Encès
Once physically and electrically connected, apply power to the sensor. The sensor will immediately begin measuring pressure and outputting an analog signal.
5.2 Reading the Analog Signal
El sensor proporciona un volum analògictage output that corresponds to the measured pressure. For the 0-5 BAR model, the typical output range is 0.5V to 4.5V. You will need a suitable analog-to-digital converter (ADC) or control system (e.g., PLC, microcontroller) to interpret this voltage into a pressure reading.
Example Conversion (for 0-5 BAR, 0.5V-4.5V output):
- 0.5V typically corresponds to 0 BAR.
- 4.5V typically corresponds to 5 BAR.
The pressure (P) can be calculated from the measured voltage (V_out) using a linear interpolation formula:
P = ((V_out - V_min) / (V_max - V_min)) * (P_max - P_min) + P_min
On:
- V_out = Measured output voltage
- V_min = Minimum output voltage (p. ex., 0.5 V)
- V_max = Maximum output voltage (p. ex., 4.5 V)
- P_min = Minimum pressure (e.g., 0 BAR)
- P_max = Maximum pressure (e.g., 5 BAR)
5.3 Consideracions ambientals
Ensure the operating environment is within the sensor's specified temperature and humidity ranges. While the sensor has IP65 protection, avoid prolonged exposure to harsh chemicals or extreme physical impact.
6. Manteniment
The Walfront pressure sensor is designed for low maintenance. However, periodic checks can help ensure its longevity and accuracy.
- Neteja: If the sensor's exterior becomes dirty, wipe it with a soft, damp cloth. Do not use abrasive cleaners or solvents that could damage the stainless steel or sealing materials. Ensure the pressure port is clear of debris.
- Comprovació de la connexió: Periodically inspect the physical and electrical connections for any signs of corrosion, loosening, or damage. Tighten connections as needed.
- Comprovació de calibratge: For critical applications, periodically verify the sensor's readings against a known, calibrated pressure source. If significant drift is observed, consider recalibration or replacement.
- Emmagatzematge: If the sensor is to be stored for an extended period, ensure it is clean, dry, and protected from extreme temperatures and physical shock.
7. Solució De Problemes
7.1 No Output or Incorrect Readings
- Comproveu la font d'alimentació: Verify that the sensor is receiving the correct input voltage (5 ± 0.25 VDC or 5~32 VDC) and that the polarity is correct.
- Cablejat: Double-check all electrical connections against the wiring diagram (Figure 3). Ensure no wires are loose, shorted, or incorrectly connected.
- Aplicació de pressió: Confirm that pressure is actually being applied to the sensor and that the pressure is within the 0-5 BAR measuring range.
- Measurement Equipment: Ensure your receiving equipment (ADC, PLC) is correctly configured to read the analog voltage signal (0.5V-4.5V) and that its input impedance is suitable.
- Physical Blockage: Inspect the pressure port for any blockages or debris that might prevent accurate pressure transmission.
7.2 Leaks at Connection Point
- Estancament: Ensure the G3/8 screw connection is adequately tightened.
- Segellat: Verify that appropriate sealing tape (e.g., PTFE tape) or thread sealant was used during installation and that it is applied correctly.
- Danys: Inspect the threads on both the sensor and the mating port for any damage that could prevent a proper seal.
7.3 Sensor Not Responding
- Environmental Extremes: Check if the sensor has been exposed to temperatures or pressures outside its specified operating limits, which could cause permanent damage.
- Danys físics: Inspect for any visible physical damage to the sensor casing or cable.
8. Garantia i Suport
8.1 Política de devolució
This product is typically covered by a 30-day return policy for refunds or replacements, subject to the terms and conditions of your purchase. Please refer to your purchase documentation for specific details.
8.2 Atenció al client
For further assistance, technical inquiries, or support regarding your Walfront pressure sensor, please contact Walfront customer service through the retailer where the product was purchased. Walfront is committed to providing quality goods and services.