Introducció

The CEM DT-6650 Multifunction Installation Tester is a high-performance instrument designed for comprehensive electrical installation testing. It features a 3.5-inch TFT color LCD display for clear readings and supports a wide range of measurements including Voltage, Insulation Resistance, Earth Resistance, Loop Impedance, RCD (Residual Current Device), PFG (Prospective Fault Current), and PSC (Prospective Short-Circuit Current). Its robust design includes IP67 protection against dust and water ingress, making it suitable for various environments. Data transfer capabilities via USB and Bluetooth allow for easy analysis and sharing of test results.

Informació de seguretat

Always adhere to local and national safety regulations when using this instrument. Failure to do so may result in injury or damage to the device. Before each use, inspect the tester and test leads for any damage. Do not use the device if it appears damaged or is not operating correctly. Ensure proper personal protective equipment (PPE) is worn during testing. Disconnect power to circuits before performing resistance or insulation tests.

  • Ensure the device is turned off before connecting or disconnecting test leads.
  • No supereu les classificacions màximes d'entrada per a cap funció.
  • Avoid using the device in wet or explosive environments unless specifically rated for such conditions.
  • The Safe Earth Volt Touchpad detects raised earth voltages greater than 50 V, indicating potentially dangerous situations.

Producte acabatview

The DT-6650 is designed for ease of use with a clear display and intuitive controls.

CEM DT-6650 Multifunction Installation Tester with test leads connected

Figura 1: Frontal view of the CEM DT-6650 Multifunction Installation Tester with test leads connected.

CEM DT-6650 with labels for TEST Button, Warning Lamp, Navigation Button, Software Buttons, POWER/ESC Button, HELP Button, and 3.5 inch Color Active Matrix Display

Figure 2: Key components and controls of the DT-6650, including the 3.5-inch TFT color LCD display (320x240 pixels).

posterior view of CEM DT-6650 showing hidden connection port with PE-protected field input, Line Input, and Neutral Input

Figura 3: posterior view showing the hidden connection port for Line, Neutral, and PE-protected field inputs.

lateral view of CEM DT-6650 showing video output, USB connector, power outlet, Micro SD Card Slot, and System Reset button

Figura 4: lateral view illustrating the multiple output options including Video output, USB connector, Power outlet, Micro SD Card Slot, and System Reset button.

Configuració

  1. Desembalatge: Carefully remove the DT-6650 and all accessories from the packaging. Verify all components listed in the packing accessories section are present.
  2. Encès: Connect the power adapter to the device and a suitable power outlet. Alternatively, ensure the internal battery is charged.
  3. Connexió dels cables de prova: Insert the red and black test leads into the appropriate input terminals as indicated on the device. For specific tests, additional leads (e.g., green for earth resistance) may be required. Ensure connections are secure.
  4. Comprovació inicial: Turn on the device using the POWER/ESC button. The 3.5-inch TFT color LCD display should illuminate.

Instruccions de funcionament

The DT-6650 offers a variety of testing functions. Select the desired function using the rotary dial and navigate menus with the navigation buttons.

Voltage Mesura

Per mesurar voltage, select the Voltage function on the rotary dial. Connect the test leads to the circuit points where voltage is to be measured. The device will display the voltage reading on the screen.

Video 1: Demonstrates voltage measurement in an office socket and a factory electrical room using the DT-6650. This video highlights the device's application in real-world scenarios for voltage proves.

CEM DT-6650 measuring voltage en un quadre elèctric

Figure 5: The DT-6650 being used to measure voltage within an electrical panel, showing the clear display of readings.

Prova de resistència a l'aïllament

For insulation resistance, select the INSULATION function. Connect the test leads to the circuit under test. Press the TEST button to initiate the measurement. The device offers various voltage and resistance selection options for customized settings.

CEM DT-6650 performing an insulation resistance test

Figure 6: Performing an insulation resistance test, demonstrating the device's capability to measure insulation integrity.

Earth Resistance Test

To perform an earth resistance test, select the RE (Earth Resistance) function. Connect the test leads and auxiliary earth spikes as per the diagram in the manual. Press the TEST button. The device will display the earth resistance value.

CEM DT-6650 performing an earth resistance test outdoors

Figure 7: The DT-6650 conducting an earth resistance test in an outdoor setting, showing the use of auxiliary earth spikes.

Loop Impedance Test

Select the LOOP function for loop impedance measurements. Connect the test leads to the live and earth terminals of the circuit. Press the TEST button. The device performs a fast high current loop test and displays the impedance.

CEM DT-6650 performing a fast high current loop test

Figure 8: The DT-6650 performing a fast high current loop test, essential for verifying circuit protection.

RCD Test (Residual Current Device)

Select the RCD function. The DT-6650 supports variable RCD current modes for customized settings and provides PASS/FAIL indications. Connect the test leads to the RCD protected circuit and initiate the test. The device will measure the trip time and current.

CEM DT-6650 showing variable RCD current mode settings

Figure 9: The DT-6650 display showing options for variable RCD current mode settings, allowing for precise testing.

Transferència i anàlisi de dades

The DT-6650 supports SD memory, USB, and Bluetooth interfaces for data transfer. Use the mobile application to view and analyze recorded data.

CEM DT-6650 connected to a smartphone app for data analysis

Figure 10: The DT-6650 connected to a smartphone via Bluetooth, demonstrating the mobile application's interface for data viewing i anàlisi.

Manteniment

Regular maintenance ensures the longevity and accuracy of your DT-6650.

  • Neteja: Netegeu el dispositiu amb un suau, damp tela. No utilitzeu netejadors abrasius ni dissolvents.
  • Emmagatzematge: Store the device in its durable carry case in a cool, dry place when not in use.
  • Cura de la bateria: Ensure the battery is charged regularly, especially before long periods of storage.
  • Calibració: Periodic calibration by qualified personnel is recommended to maintain measurement accuracy.

Resolució de problemes

ProblemaCausa possibleSolució
El dispositiu no s'encén.Problema amb la bateria baixa o l'adaptador de corrent.Charge the battery or check power adapter connection.
Lectures inexactes.Damaged test leads, improper connection, or device needs calibration.Inspect test leads, ensure secure connections, consider professional calibration.
Problemes de connectivitat Bluetooth.Bluetooth not enabled on device/phone, out of range, or interference.Ensure Bluetooth is on, move closer to the device, try again in a different location.

Especificacions

CaracterísticaDetall
Mostra3.5 inch TFT color LCD display (320 x 240 pixels)
FuncionsVoltage, Insulation Resistance, Earth Resistance, Loop Impedance, RCD, PFG, PSC
Classificació de proteccióIP67 (dust ingress and water)
ConnectivitatSD memory, USB, Bluetooth interface
Font d'alimentacióFunciona amb bateria
Dimensions10.5 x 6 x 5.1 polzades
Pes8.5 lliures
Número de modelDT-6650+

Garantia i Suport

For warranty information and technical support, please refer to the official CEM weblloc web o poseu-vos en contacte amb el seu servei d'atenció al client. Conserveu el rebut de compra com a comprovant de compra per a reclamacions de garantia.

Informació de contacte:

  • Weblloc: www.cem-instruments.com
  • Atenció al client: Consulteu el weblloc web per obtenir dades de contacte regionals.

Documents relacionats - DT-6650+

Preview Provador d'instal·lacions multifunció CEM DT-6650: especificacions tècniques i característiques
Informació detallada sobre el provador d'instal·lacions multifunció CEM DT-6650, incloent-hi les seves característiques, especificacions tècniques, informació de seguretat i accessoris. Aquest provador està dissenyat per a proves de seguretat d'instal·lacions elèctriques en aplicacions domèstiques, comercials i industrials.
Preview CEM DT-5301 Digital Loop/PSC Tester: Specifications and Features
Detailed specifications, features, and electrical characteristics of the CEM DT-5301 Digital Loop and Prospective Short Circuit Current (PSC) Tester. Includes general specifications, loop resistance, prospective short current, and AC voltage mesures.
Preview Manual d'usuari del mesurador de gruix de recobriment CEM Pro DT-156H
Manual d'usuari complet per al CEM Coating Thickness Gauge Pro (DT-156H). Inclou informació general, característiques, especificacions, funcionament, calibratge, configuració, resolució de problemes i més.
Preview Termòmetre digital CEM DT-612: especificacions tècniques i característiques
Informació detallada sobre el termòmetre digital CEM DT-612, incloses les seves especificacions elèctriques i ambientals, característiques i accessoris. Aquest dispositiu portàtil utilitza termoparells de tipus K per a mesures precises de temperatura.
Preview Manual d'usuari del detector de concentració de massa de partícules CEM DT-9680
Manual d'usuari del detector de qualitat de l'aire CEM DT-9680. Coneix les seves característiques, especificacions, funcionament, configuració i estàndards de qualitat de l'aire per detectar PM2.5, PM10, CO2, HCHO i TVOC.
Preview Инструкция по эксплуатации электроизмерительных клещей CEM DT-3348
Подробная инструкция по эксплуатации цифровых токовых клещей CEM DT-3348, охватывающая безопасности, описание устройства, процедуры измерений и обслуживание.