Introducció
This manual provides comprehensive instructions for the safe and effective use of the Valefod LM2596 DC-DC Buck Converter with LED Display. This module is designed to step down a DC input voltage to a lower, adjustable DC output voltage, featuring an integrated LED display for real-time voltagSeguiment.

Image 1: Three Valefod LM2596 DC-DC Buck Converter modules.
Informació de seguretat i notes importants
- Entrada Voltage Requisit: El volum d’entradatage must be at least 1.5V higher than the desired output voltage. This module is a buck (step-down) converter and cannot boost voltage.
- Polaritat: Ensure correct polarity when connecting input and output wires. Do not reverse the input and output interfaces to prevent damage to the module.
- Output Current/Power: Keep the output current under 2A (or 15W). For prolonged operation at higher loads, a heat sink is recommended to prevent overheating.
- Seguretat elèctrica: Always disconnect power before making any connections or adjustments. Exercise caution when working with electrical circuits.
Característiques del producte
- DC-DC step-down module with integrated LED digital voltmeter.
- Thickened circuit boards and advanced solid-state capacitors for stable performance.
- Short circuit and over-temperature protection.
- Vol de sortida ajustabletage via a multi-turn potentiometer.
- Display can show either input or output voltage.

Imatge 2: Primer pla view of a single LM2596 module.
Configuració i connexions
Before connecting the module, ensure all power sources are disconnected.
- Identificar terminals: Locate the "IN+" (Input Positive), "IN-" (Input Negative), "OUT+" (Output Positive), and "OUT-" (Output Negative) screw terminals on the module.
- Connexió d'entrada: Connect your DC power source to the "IN+" and "IN-" terminals. Ensure the positive lead of your power source connects to "IN+" and the negative lead to "IN-".
- Connexió de sortida: Connect your load (the device requiring regulated voltage) to the "OUT+" and "OUT-" terminals. Ensure the positive lead of your load connects to "OUT+" and the negative lead to "OUT-".
- Vol inicialtage Ajust: Before applying power to your load, it is recommended to pre-adjust the output voltage. Connect a multimeter to the output terminals and adjust the potentiometer until the desired voltages mostra e.

Image 3: Module layout and connection points.
Instruccions de funcionament
Voltage Ajust
El voltage is adjusted using the blue multi-turn potentiometer located on the module.
- Use a small screwdriver to turn the screw on the potentiometer.
- Girant en sentit horari will generally augmentar el vol de sortidatage.
- Girant en sentit antihorari will generally disminuir el vol de sortidatage.
- Nota: The factory default setting often results in a high output voltage. You may need to turn the potentiometer counter-clockwise approximately 7-15 full rotations before the voltage begins to decrease. Each full rotation typically adjusts the voltage by about 1V.
Digital Voltmeter Operation
The integrated LED display provides real-time voltage lectures.
- ON/OFF Button (Left Button):
- Premsa curta: Toggles the digital voltmeter display ON or OFF.
- Long Press (>1s, <4s): Shuts down the digital voltmeter display.
- Long Press (>4s): Enters voltage measurement self-calibration mode (see Calibration section).
- Mode Button (Right Button):
- Premsa curta: Switches the display between input voltage ("IN" indicator light) and output voltage ("OUT" indicator light).
- Long Press (>2s): Used during calibration to switch between input and output calibration, and to save calibrated values.
Voltmeter Calibration (Optional)
This procedure is for users requiring highly accurate voltage readings from the integrated voltmeter. The factory setting is 0.0V deviation.
- Entra al mode de calibratge: With the module powered on, long press the left "ON/OFF" button for more than 4 seconds. The "IN" indicator light will illuminate, signifying input voltage measurement calibration has started. The display will show a calibration value (e.g., "0.0").
- Calibrate Input Voltage: Connect a precise external voltmeter to the input terminals. Compare the reading on the module's display with the external voltmeter.
- Tap the left button to decrease the displayed value.
- Tap the right button to increase the displayed value.
- Each tap adjusts by a small unit (less than 0.1V). You may need to tap 1-5 times to see a 0.1V change. Adjust until the module's display matches your external voltmeter.
- Switch to Output Calibration: After calibrating the input voltage, long press the right "Mode" button for more than 2 seconds. The "OUT" indicator light will illuminate, signifying output voltage measurement calibration has started.
- Calibra el volum de sortidatage: Connect a precise external voltmeter to the output terminals. Compare the reading on the module's display with the external voltmeter.
- Tap the left button to decrease the displayed value.
- Tap the right button to increase the displayed value.
- Adjust until the module's display matches your external voltmeter.
- Desa el calibratge: After calibrating both input and output, long press the right "Mode" button for more than 2 seconds. The adjusted values will be saved (retained even after power loss), and the module will return to normal voltage mode de visualització.
Especificacions
| Característica | Detall |
|---|---|
| Model | LM2596 / Digital Tube Voltmeter |
| Entrada Voltage | CC 4V - 40V |
| Vol. De sortidatage | DC 1.5V - 35V (adjustable) |
| Corrent de sortida | 3A (màxim) |
| Eficiència de conversió | 92% (màxim) |
| Freqüència de commutació | 150 KHz |
| Temperatura de funcionament | -45 ℃ a + 85 ℃ |
| Dimensions (L x A x A) | 57 mm x 36 mm x 13 mm |
| Pes | 21 g per mòdul |

Image 4: Module dimensions.
Resolució de problemes
- Sense Vol de sortidatage / Display Off:
- Check input power supply connections and ensure it is within the 4V-40V range.
- Verify input polarity.
- Ensure the left "ON/OFF" button has been short-pressed to activate the display.
- Vol. De sortidatage Not Adjusting:
- Confirmeu l'entrada voltage is at least 1.5V higher than the desired output.
- Turn the potentiometer counter-clockwise multiple rotations (7-15) as the default setting might be at maximum voltage.
- Ensure the potentiometer is not damaged.
- Sobreescalfament del mòdul:
- Reduce the output current or power draw.
- Assegureu-vos que hi hagi una ventilació adequada al voltant del mòdul.
- Consider adding a heat sink if operating continuously near the maximum current/power limits (2A or 15W).
- Inaccurate Voltmeter Reading:
- Perform the voltmeter calibration procedure detailed in this manual.
- Ensure connections to the external multimeter are secure and accurate during calibration.
Manteniment
The Valefod LM2596 module requires minimal maintenance.
- Mantingueu el mòdul net i lliure de pols i deixalles.
- Avoid exposing the module to excessive moisture or extreme temperatures outside its operating range.
- Periodically check connections for tightness and ensure no wires are frayed or damaged.
Garantia i Suport
For warranty information or technical support, please refer to the product's purchase platform or contact Valefod customer service directly. Please have your model number (LM2596 / VA-0162-BL) and purchase details available when contacting support.