Walfront Walfrontkc8b0o4p9e-02

Walfront 4 Channel Relay Module Board 12V User Manual

Model: Walfrontkc8b0o4p9e-02

1. Producte acabatview

The Walfront 4 Channel Relay Module Board is a versatile electronic component designed to control high-power devices using low-voltage signals. It features photocoupler isolation for enhanced safety and stable performance, protecting your control circuit from the load circuit. This 12V version is suitable for various applications requiring switching capabilities.

Walfront 4 Channel Relay Module Board 12V

Figura 1: superior view of the Walfront 4 Channel Relay Module Board.

The module incorporates a fault-tolerant design, ensuring that the relay remains in its current state even if the control line is accidentally disconnected. It provides clear visual feedback with a green power indicator light and red indicator lights for each of the four relays, showing their operational status.

Walfront 4 Channel Relay Module with indicator lights and terminal connections

Figure 2: Walfront Relay Module highlighting power and relay state indicator lights, and terminal connections.

2. Característiques

  • Photocoupler Isolation: Utilizes patch photocoupler isolation for strong driving ability and stable performance, with a current of 5mA.
  • Vol. múltipletage Opcions: Available in 5V, 12V, and 24V operating voltages (this specific model is 12V).
  • High & Low Level Trigger: Each relay can be triggered by either a high-level or low-level signal, configurable via jumper settings.
  • Fault-Tolerant Design: Prevents unintended relay activation even if the control line breaks.
  • User-Friendly Interfaces: All interfaces are designed for direct connection via terminal blocks, ensuring convenient wiring.
  • Indicadors visuals: Features a green power indicator light and individual red indicator lights for each of the four relays.
  • Forats de muntatge: Four fixing holes are provided for secure installation.

3. Especificacions

CaracterísticaEspecificació
ModelWalfrontkc8b0o4p9e-02
Vol. Operatiutage12V DC
Nombre de canals4
Tipus d'aïllamentPhotocoupler Isolation
Corrent de disparador5 mA
Nivell de disparadorHigh or Low (Jumper Selectable)
Common Interface Load (AC)250V/10A
Common Interface Load (DC)30V/10A
Module Size (L*W*H)73*50*18.5mm / 2.9*2*0.7inch
Fixing Hole Diameter3.1 mm
Pes de l'article60 g
Tipus de muntatgeMuntatge del tauler
Material de contacteSilver or Gold
Tipus de contacteNormalment tancat (NC)
Walfront 4 Channel Relay Module 5V, 12V, 24V variants

Figure 3: The Walfront 4 Channel Relay Module is available in 5V, 12V, and 24V versions. This manual pertains to the 12V model.

4. Configuració i cablejat

Proper setup and wiring are crucial for the safe and correct operation of the relay module. Always ensure power is disconnected before making any connections.

4.1 Disseny del mòdul

A dalt view of Walfront 4 Channel Relay Module with labeled terminals

Figura 4: Detall superior view of the relay module showing power, input, and output terminals.

4.2 Connexió a la font d'alimentació

Connect a 12V DC power supply to the module's power input terminals:

  • DC+: Connect to the positive (+) terminal of your 12V DC power supply.
  • DC-: Connect to the negative (-) terminal of your 12V DC power supply.

The green power indicator LED will illuminate when power is correctly applied.

4.3 Connexió del senyal d'entrada

Connect your control signals (e.g., from a microcontroller like Arduino, Raspberry Pi) to the input terminals:

  • IN1, IN2, IN3, IN4: These are the control input pins for each of the four relays. Connect your digital output pins from your control device to these inputs.

4.4 Load Connection (Relay Output)

Each relay has three terminals for connecting your load:

  • NO (normalment obert): This terminal is open (disconnected) when the relay is de-energized and closes (connects to COM) when the relay is energized.
  • COM (Comú): This is the common terminal. Connect one side of your load's power source here.
  • NC (normalment tancat): This terminal is closed (connected to COM) when the relay is de-energized and opens (disconnects from COM) when the relay is energized.

Choose between NO and NC depending on whether you want the load to be ON or OFF by default when the relay is not triggered.

Schematic Diagram of Relay Connection

Figura 5: Example schematic for connecting a load to a relay terminal.

4.5 Jumper Settings for Trigger Level (S1-S4)

The module allows you to select the trigger level for each relay independently using jumpers S1, S2, S3, and S4. Each jumper corresponds to one relay (S1 for IN1, S2 for IN2, etc.).

  • LOW (L): When the jumper is placed on the 'LOW' side, the relay will activate when the corresponding input pin (INx) receives a low-level signal (0V or ground).
  • HIGH (H): When the jumper is placed on the 'HIGH' side, the relay will activate when the corresponding input pin (INx) receives a high-level signal (e.g., 5V for a 5V logic system).

Ensure the jumper settings match the logic level of your control device's output signals.

5. Instruccions de funcionament

Once the module is correctly wired and powered, you can control the relays by sending appropriate signals to the IN1-IN4 pins.

  • Relay Activation: When an input pin (INx) receives the configured trigger signal (high or low, as set by the jumper), the corresponding relay will energize. The red indicator light for that relay will illuminate.
  • Canvi de càrrega: Upon activation, the relay's internal switch will change state: NO will connect to COM, and NC will disconnect from COM. This will switch your connected load ON or OFF.
  • Relay Deactivation: When the input pin (INx) receives the opposite signal (or no signal, depending on your control circuit), the relay will de-energize. The red indicator light will turn off, and the relay contacts will return to their default (Normally Closed/Normally Open) state.

Per example, if a jumper is set to 'HIGH' for IN1, sending a 5V signal to IN1 will activate Relay 1. If it's set to 'LOW', sending a 0V signal will activate Relay 1.

Video 1: A demonstration of a 4-channel relay module in operation, showing the switching action.

6. Manteniment

The Walfront 4 Channel Relay Module is designed for durability and requires minimal maintenance. Follow these guidelines to ensure its longevity:

  • Mantenir sec: Protect the module from moisture and humidity to prevent corrosion and short circuits.
  • Neteja: Keep the board free from dust and debris. Use a soft, dry brush or compressed air for cleaning if necessary. Avoid using liquid cleaners.
  • Temperatura: Operate the module within its specified temperature range. Avoid extreme heat or cold.
  • Danys físics: Handle the module with care to prevent physical damage to components or solder joints.
  • Power Off Before Adjustments: Always disconnect power before making any wiring changes or adjusting jumpers.

7. Solució De Problemes

If you encounter issues with your relay module, consider the following troubleshooting steps:

  • El mòdul no s'encén:
    • Check if the 12V DC power supply is correctly connected to DC+ and DC-.
    • Verify that the power supply is providing the correct voltage (12V) and sufficient current.
    • Ensure the power indicator (green LED) is illuminated.
  • Relé no activat:
    • Confirm that the input signal (INx) from your control device is correctly connected.
    • Check the jumper setting (S1-S4) for the corresponding relay. Ensure it matches the logic level of your control signal (HIGH for high-level trigger, LOW for low-level trigger).
    • Verify that your control device is actually sending the correct trigger signal. Use a multimeter to check the voltage at the INx pin.
    • Note: Some 3.3V microcontrollers may not reliably drive the relay when set to active-LOW if the module expects a true 0V for low. Ensure your control signal is strong enough.
    • Check if the red indicator LED for the specific relay illuminates when the trigger signal is applied.
  • Càrrega no commutadora:
    • Ensure the load is correctly wired to the COM and either NO or NC terminals.
    • Verify that the load itself is functional and its power source is connected.
    • Check if the load's current and voltage requirements are within the relay's specifications (AC 250V/10A, DC 30V/10A). Overloading can damage the relay.
  • Funcionament intermitent:
    • Inspect all wiring for loose connections.
    • Ensure the power supply is stable and free from voltage fluctuacions.

8. Garantia i Suport

Walfront products are manufactured to high-quality standards. For any technical assistance or support inquiries, please refer to the retailer or contact Walfront customer service through their official channels. Please retain your proof of purchase for warranty claims.

Documents relacionats - Walfrontkc8b0o4p9e-02

Preview Guia de l'usuari del mòdul disparador USB PD Joy-IT COM-ZYPDS-02
Guia d'usuari del mòdul de disparador USB PD Joy-IT COM-ZYPDS-02. Apreneu a configurar el volum de sortida.tagés (5V, 9V, 12V) mitjançant ajustos de soldadura per a aplicacions de subministrament d'alimentació USB-C.
Preview IoTextra Octal2 8-Channel Digital I/O Module - Datasheet
Technical datasheet for the IoTextra Octal2, an 8-channel digital I/O module with 4 inputs and 4 outputs. Features include galvanic isolation, multiple operating modes (GPIO, I2C), and compatibility with various microcontrollers for industrial, robotics, and smart home applications.
Preview GEYA GRL8 Level Control Relay Instruction Manual
Instruction manual for the GEYA GRL8 series level control relays (GRL8-01, GRL8-02). Provides technical specifications, application details, function configurations, wiring diagrams, and operational guidance for monitoring fluid levels in tanks, reservoirs, and wells.
Preview Finder Series 41 Low-Profile PCB Relays and SSRs - Technical Data
Comprehensive technical datasheet for Finder Series 41 low-profile PCB relays and Solid State Relays (SSRs), detailing specifications, applications, ordering codes, and accessories.
Preview Finder 83.02 Ex Multifunction Time Relay - Technical Datasheet
Detailed technical specifications, certifications, installation, and safety guidelines for the Finder 83.02 Ex multifunction time relay, suitable for hazardous locations (ATEX, IECEx, Hazloc).
Preview Finder 83.02 Multifunction Time Relay - Technical Datasheet
Detailed technical specifications, functions, and operating instructions for the Finder 83.02 multifunction time relay, including connection diagrams and timing charts.