1. Producte acabatview
The Hilitand PEACEFAIR PZEM-022 is a digital AC power meter designed to accurately measure and display various electrical parameters. This device provides real-time monitoring of voltage, current, active power, energy consumption, frequency, and power factor for AC circuits. It is equipped with a closed-type current transformer (CT) for easy installation and precise measurement up to 100A.

Figure 1: Hilitand PEACEFAIR PZEM-022 Digital AC Power Meter with its compact design.
2. Característiques clau
- Pantalla completa: Large-screen LCD simultaneously displays 6 parameters: Power, Energy, Voltage, Current, Frequency, and Power Factor.
- Electrical Parameter Measurement: Accurately measures voltage, corrent, potència activa, energia, freqüència i factor de potència.
- Power Alarm Threshold: Allows users to set a power alarm threshold.
- Overload Alarm Function: When the power alarm threshold is exceeded, the backlight and power display will flash to indicate an overload.
- Energy Data Reset: Energy data can be cleared and reset using a dedicated button.
- Emmagatzematge de dades: Automatically stores data when power is off, ensuring no loss of accumulated energy readings.
3. Contingut del paquet
El paquet inclou els articles següents:
- 1 x AC Multifunction Digital Meter (PZEM-022)
- 1 x Closed Type Current Transformer (CT)

Figure 2: The PZEM-022 meter shown with its accompanying closed-type current transformer (CT).
4. Configuració i instal·lació
Follow these instructions carefully for proper installation of your PZEM-022 digital AC power meter.
4.1 Esquema de cablejat
Refer to the diagram below for correct wiring. Ensure all connections are secure before applying power.

Figure 3: Detailed wiring diagram for the PZEM-022 meter and CT. The load's L or N line must pass through the CT.
- The wiring does not distinguish between L (Live) and N (Neutral) lines for the meter's power input.
- The CT (Current Transformer) and input voltage connections must be correct. Do not connect the corresponding terminals incorrectly.
- One of the load's power lines (either L or N) must pass through the CT in a single loop.
4.2 Guia de vídeo d'instal·lació
Watch this video for a visual guide on how to connect the PZEM-022 meter and its current transformer.
Video 1: Demonstrates the wiring process for the PZEM-022 digital AC power meter, showing how to connect the input voltage, CT, and load according to the wiring diagram.
5. Instruccions de funcionament
5.1 Interfície de visualització
The large LCD screen displays the following electrical parameters simultaneously:
- Voltage (V)
- Corrent (A)
- Potència activa (W)
- Energia (Wh)
- Freqüència (Hz)
- Factor de potència (PF)
5.2 Clearing Energy Data
To clear the accumulated energy data (Wh), follow these steps:
- Press and hold the button on the front of the meter for approximately 5 seconds.
- The energy number (Wh) on the display will start flashing. Release the button.
- Press the button briefly again. The energy data will be cleared, and the flashing state will stop.
- If no button action occurs within 5 seconds after the energy number starts flashing, the data will not be cleared, and the meter will exit the clear state.
This function allows you to reset energy consumption readings for new measurement periods.
5.3 Energy Data Clearing Video Guide
This video demonstrates how to clear the energy data on the PZEM-022 meter.
Video 2: Shows the process of long-pressing the button to initiate energy data clearing and a short press to confirm the reset.
6. Manteniment
The Hilitand PEACEFAIR PZEM-022 meter requires minimal maintenance. To ensure optimal performance and longevity:
- Mantingueu el dispositiu net i lliure de pols i humitat. Feu servir un drap suau i sec per netejar-lo.
- Avoid exposing the meter to extreme temperatures or direct sunlight for prolonged periods.
- Regularly check wiring connections to ensure they remain secure.
- Do not attempt to open or repair the device yourself, as this may void the warranty and pose a safety risk.
7. Solució De Problemes
If you encounter issues with your PZEM-022 meter, refer to the following common problems and solutions:
| Problema | Causa possible | Solució |
|---|---|---|
| Sense pantalla/Apagat | No power supply or loose wiring. | Comproveu el vol d'entradatage connection. Ensure the meter is receiving power within its operating range (80-260VAC). |
| Incorrect current/power reading | CT not installed correctly or faulty. | Ensure only one load wire passes through the CT. Verify the CT is securely connected to the meter. |
| Overload alarm flashing | Connected load exceeds the set power alarm threshold. | Reduce the load connected to the circuit or adjust the power alarm threshold if necessary. Ensure the load does not exceed the meter's rated power (100A/22000W). |
| Energy data not clearing | Seqüència incorrecta de prémer els botons. | Follow the "Clearing Energy Data" instructions precisely (long press until flashing, then short press to confirm). |
Si el problema persisteix, poseu-vos en contacte amb l'atenció al client.
8. Especificacions tècniques
| Paràmetre | Valor |
|---|---|
| Marca | Hilitand (PEACEFAIR) |
| Model | PZEM-022 |
| Voltage | 80 ~ 260 VCA |
| Prova Voltage | 80 ~ 260 VCA |
| Actual | 100A |
| Potència nominal | 100A/22000W |
| Freqüència de funcionament | 45-65 Hz |
| Precisió de la mesura | 1.0è grau |
| Dimensions | 9 x 5 x 2.5 cm (3.5 x 2 x 1 polzades) |
| Wire Length (CT) | 19 cm (7.5 polzades) |
| Pes | Aprox. 110 g (3.9 oz) |
| Font d'alimentació | AC voltage |
| Estil | Digital |
| Color | Negre |
| País d'origen | Xina |

Figure 4: Detailed dimension diagram of the PZEM-022 meter in millimeters.
9. Precaucions de seguretat
To ensure safe operation and prevent damage to the device or personal injury, please observe the following precautions:
- Aquest mòdul està dissenyat per a només per a ús interior. Do not use it outdoors.
- The applied load must not exceed the rated power of 100A/22000W. Overloading can cause damage and safety hazards.
- Assegureu-vos el wiring sequence is correct as per the provided diagram. Incorrect wiring can lead to malfunction or damage.
- Installation should only be performed by qualified personnel to avoid electrical shock or other hazards.
- Desconnecteu sempre l'alimentació abans de realitzar qualsevol cablejat o manteniment.
10. Garantia i Suport
We are committed to customer satisfaction. If this product does not meet or exceed your expectations, or if you encounter any issues, please contact us immediately. We will work to resolve the problem promptly.
For further assistance, please refer to the contact information provided with your purchase or visit the Hilitand store on Amazon: Hilitand Store.