This manual provides essential information for the installation, operation, and maintenance of your Astralpool Multiport Valve NPT, Top Mount 1-1/2". This valve is designed for use with pool and spa filtration systems, allowing for various operational modes to manage water flow and filtration processes effectively.

The Astralpool Multiport Valve is a critical component for maintaining clean and clear pool water, offering robust construction and reliable performance.

Astralpool Multiport Valve, front view

Figura 1: Frontal view of the Astralpool Multiport Valve, showing the handle and main body.

Configuració i instal·lació

Proper installation is crucial for the safe and efficient operation of the multiport valve. Always ensure the pump is turned off and depressurized before beginning installation.

1. Comprovacions prèvies a la instal·lació

  • Verify that the valve model (22358) matches your filter system requirements.
  • Ensure all necessary plumbing fittings (1-1/2" NPT) are available and in good condition.
  • Inspect the valve for any visible damage from shipping.

2. Mounting the Valve

The valve is designed for top-mount installation on compatible sand filters. The valve typically connects to the filter tank via a central pipe (standpipe) and secures with a clamp or threaded connection.

  1. Ensure the filter tank's standpipe is clean and free of debris.
  2. Carefully lower the multiport valve onto the standpipe, ensuring a snug fit.
  3. Align the valve's ports with the corresponding plumbing lines (pump, return, waste).
  4. Secure the valve to the filter tank using the provided clamp or threading, ensuring a watertight seal. Do not overtighten.
Astralpool Multiport Valve, side view amb ports

Figura 2: lateral view of the multiport valve, highlighting the various connection ports for plumbing.

3. Connexions de fontaneria

Connect the pool plumbing to the valve's ports. The valve features NPT (National Pipe Tapered) connections for secure, leak-free attachment.

  • PUMP/INLET: Connect the pipe coming from the pool pump.
  • RETURN/OUTLET: Connect the pipe leading back to the pool.
  • RESIDUS: Connect the pipe leading to a waste line or drain.

Precaució:

  • Use appropriate thread sealant (e.g., PTFE tape or pipe dope) on all threaded connections.
  • Ensure all connections are tight but do not overtighten, which can damage the plastic threads.
  • Verify there are no leaks before operating the system.
Astralpool Multiport Valve, rear view with caution labels

Figura 3: posterior view of the multiport valve, showing caution labels and additional ports.

Instruccions de funcionament

Important: Always turn off the pump before changing the valve position to prevent damage to the valve or plumbing system.

The multiport valve has several positions, each serving a specific function:

PosicióFuncióDescripció
FILTREFiltració normalWater flows through the filter media, trapping debris, and returns to the pool. This is the standard operating position.
CONTRACTACIÓNeteja de filtresReverses water flow through the filter to dislodge trapped debris, which is then sent to the waste line. Perform when filter pressure rises.
ESbandidaPost-Backwash RinseAfter backwashing, this position settles the filter media and flushes any remaining dirty water to waste before returning to FILTER.
RESIDUS/DRENAUDirect to WasteBypasses the filter and sends water directly from the pump to the waste line. Used for vacuuming heavy debris directly to waste or lowering pool water level.
RECIRCULATE/BYPASSCirculate Without FilterL'aigua passa per alt el filtre i circula directament de tornada a la piscina. Útil per distribuir productes químics sense filtrar.
CLOSED/WINTERIZESystem Shut-offCloses all flow to the filter and pool. Used for servicing the pump or filter, or for winterizing the system. Never operate the pump with the valve in this position.
Astralpool Multiport Valve, top view with handle and settings

Figura 4: superior view of the multiport valve, showing the handle and the labeled positions for operation.

Manteniment

Regular maintenance ensures the longevity and optimal performance of your multiport valve.

1. Gasket and O-Ring Inspection

  • Periodically inspect the spider gasket inside the valve and the O-rings on the handle and connections for cracks, wear, or deformation.
  • Replace worn gaskets or O-rings immediately to prevent leaks and ensure proper valve function.

2. Lubricació

  • Apply a silicone-based lubricant (pool-specific) to the handle O-rings and any other moving parts that come into contact with water, as needed. This helps maintain smooth operation and prevents premature wear.

3. Hivernació (si escau)

  • In freezing climates, ensure the valve is drained completely to prevent ice damage.
  • Set the valve to the "Winterize" or "Closed" position (if available and recommended by filter manufacturer) or an "open" position to allow water to drain. Consult your filter manual for specific winterization procedures.
Astralpool Multiport Valve, bottom view

Figura 5: A baix view of the multiport valve, showing the internal structure and connection point to the filter standpipe.

Resolució de problemes

This section addresses common issues you might encounter with your multiport valve.

ProblemaCausa possibleSolució
Water leaking from valve handle or portsWorn O-rings or spider gasket; loose connections.Inspect and replace O-rings/gasket. Tighten plumbing connections. Ensure clamp és segur.
Poor filtration or cloudy waterValve not fully seated in FILTER position; clogged filter media; damaged spider gasket.Ensure valve handle is firmly in FILTER. Backwash and rinse filter. Inspect and replace spider gasket if damaged.
Difficulty changing valve positionsLack of lubrication; debris in valve; worn internal components.Ensure pump is off. Apply silicone lubricant to handle O-rings. Inspect for debris. If issue persists, internal components may need replacement.
Water continuously flowing to wasteDamaged spider gasket; valve stuck in WASTE position.Inspect and replace spider gasket. Ensure valve handle is firmly in desired position.

Especificacions

  • Marca: Astralpool
  • Número de model: 22358
  • Tipus de vàlvula: Vàlvula multiport
  • Tipus de connexió d'entrada: National Pipe Tapered (NPT)
  • Mida de la connexió: 1-1/2 polzades
  • Material: Metal (likely referring to internal components or specific parts, main body is typically durable plastic)
  • Acabat exterior: Brass (likely referring to specific fittings or internal components)
  • Dimensions del producte (L x A x A): 14.1 x 5.3 x 5.3 polzades
  • Fabricant: FLUIDRA USA

Informació de la garantia

Specific warranty terms for the Astralpool Multiport Valve Model 22358 are provided by the manufacturer, FLUIDRA USA. Please refer to the warranty card included with your product or visit the official Astralpool/FLUIDRA USA website for detailed warranty coverage, terms, and conditions. Keep your proof of purchase for warranty claims.

Atenció al client

For technical assistance, replacement parts, or further inquiries regarding your Astralpool Multiport Valve, please contact FLUIDRA USA customer support. Contact information can typically be found on the manufacturer's weblloc web o a l'embalatge del producte.

You may also consult with a certified pool professional for installation or complex troubleshooting.

Documents relacionats - 22358

Preview Vàlvula multiport AstralPool Classic Plus: guia d'instal·lació, manteniment i resolució de problemes
Guia detallada per a la vàlvula multiport AstralPool Classic Plus (model 73950-1000). Cobreix el funcionament de la vàlvula, la instal·lació pas a pas, els procediments de manteniment essencials, una llista completa de peces i solucions habituals per a la resolució de problemes dels sistemes de filtre de piscines.
Preview Guia d'instal·lació de la dutxa de piscina AstralPool Niagara
Instruccions pas a pas per instal·lar la dutxa exterior AstralPool Niagara, incloent-hi peces, diagrames de muntatge i especificacions tècniques.
Preview Manual d'instal·lació i manteniment del filtre de sorra AstralPool
Guia completa per a la instal·lació, el funcionament i el manteniment dels filtres de sorra AstralPool per a piscines, que cobreix la química de l'aigua, els principis de filtració, la resolució de problemes i la seguretat.
Preview Netejador robòtic de piscines AstralPool QB800: Manual d'usuari i guia
Aquest manual proporciona instruccions completes per a la instal·lació, el funcionament, el manteniment i la resolució de problemes del netejador robòtic de piscines AstralPool QB800.
Preview Manual d'instal·lació i manteniment de la coberta automàtica de piscina Astralpool Rousillon
Una guia completa per a la instal·lació i el manteniment de la coberta automàtica de piscina Astralpool Rousillon, que detalla els components, els requisits d'enginyeria civil, els passos de muntatge, la instal·lació elèctrica i les característiques de seguretat.
Preview Manual d'instal·lació i manteniment del broquet inferior ajustable d'Astralpool
Guia completa per a la instal·lació i el manteniment del broquet inferior ajustable Astralpool, que cobreix les característiques del producte, la instal·lació pas a pas, el muntatge, la posada en marxa i les especificacions tècniques per a una neteja òptima de la piscina.