1. Introducció
The HT10 is a two-pole multifunction tester designed for practical, quick, and functional measurements. Its narrow and long structure allows for measurements in various operating conditions. This device performs AC/DC voltage measurements with polarity indication, continuity tests with a buzzer, and phase sequence detection using LED indications and a digital display. The HT10 also measures AC voltage with low input impedance and performs RCD trip testing. It includes a white LED torch for use in dimly lit environments and complies with safety standards IEC/EN61243-3:2014/VDE 0682, IEC/EN61010-1, and IEC/61010-2-030, ensuring safe and reliable operation.
The instrument indicates dangerous voltage presence even without battery power or in case of main circuit failure. With a protection class of IP64 (dust and splash-proof) and molded soft rubber grips, the HT10 is a heavy-duty instrument suitable for demanding domestic or industrial applications.
2. Característiques clau
- Volum AC / DCtage Measurement with Polarity Indication
- Continuity Test with Buzzer
- Phase Sequence Detection with LED Indicators and Display
- Low Input Impedance AC Voltage Mesura
- RCD Trip Testing (without time or current measurement)
- Integrated White LED Torch for Illumination
- Compliance with IEC/EN61243-3:2014/VDE 0682, IEC/EN61010-1, IEC/61010-2-030
- Safety Category: CAT IV 600V, CAT III 1000V
- Protection Class: IP64 (Dust and Splash-proof)
- Funció de retenció de dades
- LED i indicacions sonores
3. Informació de seguretat
WARNING: Always read and understand all safety instructions before using this instrument. Failure to do so may result in serious injury or death.
- This instrument is designed for use by qualified personnel only.
- Do not use the instrument if it appears damaged or if the test leads are damaged.
- Verify the instrument's operation on a known voltage font abans i després de l'ús.
- Observeu tots els codis de seguretat locals i nacionals.
- No supereu les classificacions màximes d'entrada per a cap funció.
- The HT10 is rated CAT IV 600V and CAT III 1000V. Ensure the measurement category is appropriate for the application.
- Utilitzeu equips de protecció individual (EPI) adequats, com ara ulleres de seguretat i guants aïllants.
- The instrument indicates dangerous voltage even without battery power, enhancing safety.
- The device is IP64 rated, providing protection against dust and splashing water.
For detailed compliance information, refer to the official certifications:
4. Producte acabatview

Figura 4.1: Frontal view of the HT10 Multimeter, displaying the digital screen, LED indicators for voltage levels, and function buttons.

Figura 4.2: Frontal view of the HT10 Multimeter, showing an AC voltage reading on the digital display and active AC indicator.

Figura 4.3: Primer pla view of the HT10 Multimeter's probes (L1 and L2) and the integrated cable management system, showing the probe tips and connection points.

Figure 4.4: The HT10 Multimeter being used to take a measurement inside an electrical panel, demonstrating its practical application in tight spaces.

Figure 4.5: The HT10 Multimeter in operation, measuring voltage from a large industrial power socket, highlighting its robust design.

Figure 4.6: The HT10 Multimeter being used to measure within a fuse box, demonstrating the utility of its integrated LED torch in low-light conditions.

Figure 4.7: The HT10 Multimeter measuring voltage from a standard wall outlet, illustrating its versatility for common electrical tasks.

Figura 4.8: Frontal view of the HT10 Multimeter retail packaging, showing the product image and key features in German.

Figura 4.9: lateral view of the HT10 Multimeter retail packaging, listing features and specifications in German, including compliance standards and safety ratings.

Figura 4.10: lateral view of the HT10 Multimeter retail packaging, listing features and specifications in English, along with the UPC barcode (8033100185430) and compliance marks.
5. Configuració i instal·lació de la bateria
The HT10 is powered by batteries. Ensure fresh batteries are installed for optimal performance and accurate readings.
- Localitzeu el compartiment de la bateria a la part posterior de l'instrument.
- Use a suitable screwdriver to open the battery compartment cover.
- Insert the required batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Substituïu la tapa del compartiment de la bateria i fixeu-la amb el cargol.
- Before first use, or after battery replacement, it is recommended to test the instrument on a known voltage source to confirm proper operation.
6. Instruccions de funcionament
6.1. AC/DC Voltage Mesura
- Ensure the test leads are securely connected to the instrument.
- Touch the L1 and L2 probes to the points where voltage s'ha de mesurar.
- The instrument will automatically detect AC or DC voltage and display the reading on the digital screen.
- Els indicadors LED s'il·luminaran corresponents al volum detectattage level (e.g., 12V, 24V, 50V, 120V, 230V, 400V, 690V, 1000V).
- Per a DC voltage, polarity will be indicated.
6.2. Prova de continuïtat
- Assegureu-vos que el circuit que s'està provant estigui desenergitzat.
- Press the continuity test button (often indicated by an Ohm symbol or speaker icon).
- Touch the L1 and L2 probes to the two points of the circuit to be tested for continuity.
- A buzzer will sound and/or an LED will illuminate if continuity is detected (low resistance).
6.3. Detecció de la seqüència de fases
- Connect the L1 and L2 probes to the phases of a three-phase system.
- The instrument will indicate the phase rotation (L or R) using dedicated LEDs.
6.4. RCD Trip Test
- Connect the HT10 to an RCD-protected circuit.
- Activate the RCD trip test function (refer to specific button on device).
- The instrument will draw a small current to trip the RCD. This function only confirms tripping, not trip time or current.
6.5. Ús de la torxa LED
The HT10 features an integrated white LED torch for illuminating dark work areas. Activate the torch using the dedicated button (often indicated by a light bulb icon).
6.6. Data HOLD Function
Press the HOLD button to freeze the current reading on the display. Press it again to release the hold and resume live readings.
7. Manteniment i cura
- Neteja: Clean the instrument regularly with a soft, damp tela. No utilitzeu netejadors abrasius ni dissolvents.
- Emmagatzematge: Store the instrument in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.
- Substitució de la bateria: Replace batteries promptly when the low battery indicator appears to ensure accurate measurements.
- Inspecció: Periodically inspect the instrument and test leads for any signs of damage, such as cracks, frayed insulation, or exposed wiring. Do not use if damaged.
- Calibració: For professional use, periodic calibration by a qualified service center is recommended to maintain accuracy.
8. Solució De Problemes
| Problema | Causa possible | Solució |
|---|---|---|
| L'instrument no s'encén. | Piles gastades o instal·lades incorrectament. | Comproveu la polaritat de la bateria; substituïu les piles. |
| Lectures inexactes. | Low battery; dirty probes; instrument damage; out of calibration. | Replace batteries; clean probes; inspect for damage; consider professional calibration. |
| Continuity test not working. | Circuit is not de-energized; open circuit; faulty probes. | Ensure circuit is off; check for breaks in the circuit; inspect and replace probes if necessary. |
| RCD trip test fails. | RCD is faulty; circuit not properly connected. | Verify RCD functionality independently; ensure secure connection to the circuit. |
9. Especificacions
| Paràmetre | Valor |
|---|---|
| Marca | HT |
| Número de model | 1010850 |
| Tipus de mesura | Multímetre |
| Font d'alimentació | Funciona amb bateria |
| Estil | Digital |
| Color | Blanc |
| Pes de l'article | 410 grams (14.5 unces) |
| Dimensions del producte (L x A x A) | 11.81 x 3.54 x 2.56 polzades |
| Especificació de seguretat complerta | IEC/EN61010-1, IEC/61010-2-030, IEC/EN61243-3:2014/VDE 0682 |
| Categoria de seguretat | CAT IV 600V, CAT III 1000V |
| Classe de protecció | IP64 (a prova de pols i esquitxades) |
| Data de primera disponibilitat | 30 de novembre de 2020 |
10. Garantia i Suport
Aquest producte ve amb un 1 any de garantia del fabricant des de la data de compra.
For technical support, warranty claims, or service inquiries, please contact the seller or manufacturer directly. The seller for this product is Stratatek Test & Measurement.
Si us plau, conserveu el comprovant de compra per validar la garantia.