1. Introducció

This manual provides essential information for the safe and effective installation, operation, and maintenance of your Leviton LB260-GS 60A 2-Pole Plug-On Smart GFCI Branch Circuit Breaker. Please read all instructions carefully before proceeding with installation or use.

The Leviton LB260-GS is a Smart Ground Fault Circuit Interrupter (GFCI) branch circuit breaker designed for use in Leviton Load Centers. It features hydraulic magnetic technology for reliable operation across a wide temperature range and integrates with the My Leviton app for enhanced monitoring and control.

2. Informació de seguretat

WARNING: RISK OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.

  • This product must be installed and serviced by qualified electrical personnel only.
  • Turn off all power to the electrical panel before working on or installing the circuit breaker.
  • Feu servir sempre un voltage detector to confirm power is off before touching any wires or components.
  • Seguiu tots els codis i regulacions elèctriques locals i nacionals.
  • No utilitzeu aquest dispositiu si sembla malmès.

El no seguir aquestes instruccions provocarà la mort o lesions greus.

3. Producte acabatview

The Leviton LB260-GS is a 2-pole, 60-Amp Smart GFCI circuit breaker. It is designed to protect against ground faults, which can cause severe electrical shock. Its hydraulic magnetic trip technology ensures consistent performance from -40°C to 85°C (-40°F to 185°F).

Leviton LB260-GS 60A 2-Pole Smart GFCI Circuit Breaker, front view

Imatge 3.1: Davant view of the Leviton LB260-GS Smart GFCI Circuit Breaker. Shows the ON/OFF switch, 60 Amp rating, GFCI indicator, and wireless communication symbol.

Leviton LB260-GS 60A 2-Pole Smart GFCI Circuit Breaker, side view

Imatge 3.2: lateral view of the Leviton LB260-GS Smart GFCI Circuit Breaker, illustrating its compact design for plug-on installation.

Leviton LB260-GS 60A 2-Pole Smart GFCI Circuit Breaker, rear view showing bus connections

Imatge 3.3: posterior view of the Leviton LB260-GS Smart GFCI Circuit Breaker, highlighting the plug-on bus connections for easy installation into a Leviton Load Center.

Característiques principals:

  • Integració intel·ligent: Connects with the My Leviton app for energy consumption data, enhanced safety alerts, and remote control.
  • Fàcil instal·lació: Revolutionary plug-on design allows for quick and tool-free installation into Leviton Load Centers.
  • Hydraulic Magnetic Technology: Ensures precise and reliable tripping characteristics across a wide temperature range without derating.
  • Seguretat millorada: Features patented reset lockout technology, preventing reset if ground fault protection is compromised.

4. Configuració i instal·lació

Professional installation by a qualified electrician is required.

  1. Prepareu el centre de càrrega: Ensure all power to the Leviton Load Center is turned OFF at the main service disconnect. Verify with a voltage provador.
  2. Connexions de cable: The Leviton Load Center design allows branch phase and neutral connections to be made directly on the panel bus bars without the circuit breaker present. Land the branch circuit wires (hot and neutral) to the appropriate terminals on the load center bus.
  3. Install the Breaker: Align the LB260-GS circuit breaker with the desired position on the load center bus. Firmly push the breaker onto the bus until it clicks into place. No additional wiring to the breaker itself is required.
  4. Cable de terra: Connect the ground wire from the branch circuit to the ground bar in the load center.
  5. Verifica la instal·lació: Comproveu dues vegades totes les connexions per assegurar-vos que estiguin ben ajustades i que estiguin ben assegudes.
  6. Restaura l'alimentació: Once installation is complete and verified, restore power to the load center.

For a visual guide on installing Leviton Load Centers and circuit breakers, please refer to the video below:

Vídeo 4.1: An instructional video demonstrating the installation process for Leviton Load Centers and their plug-on circuit breakers, including wiring and breaker placement.

5. Instruccions de funcionament

Funcionament manual:

  • Encenent: Push the breaker handle firmly to the "ON" position.
  • Apagant: Push the breaker handle firmly to the "OFF" position.
  • Reinici d'un interruptor automàtic disparat: If the breaker trips, the handle will move to a center position. To reset, first push the handle firmly to the "OFF" position, then push it to the "ON" position. If the breaker immediately trips again, there may be an electrical fault that needs to be addressed.

GFCI Test and Reset:

The GFCI function should be tested monthly to ensure proper operation.

  1. Ensure the breaker is in the "ON" position.
  2. Press the "TEST" button on the face of the breaker. The breaker should immediately trip to the center position.
  3. To restore power, push the handle firmly to the "OFF" position, then to the "ON" position.
  4. If the breaker does not trip when the "TEST" button is pressed, or if it does not reset, the GFCI function may be faulty. Contact a qualified electrician for inspection and replacement.

Smart Features (My Leviton App):

The LB260-GS integrates with the My Leviton app, providing advanced functionality:

  • Monitorització energètica: View real-time and historical energy consumption data for the circuit.
  • Comandament a distància: Turn the breaker ON or OFF remotely via the app.
  • Notificacions: Receive alerts for electrical anomalies, tripped breakers, or other status changes.
  • Autocomprovació: The smart breaker performs self-tests and reports status to the app.

Refer to the My Leviton app documentation for detailed instructions on connecting and utilizing smart features.

6. Manteniment

  • Prova mensual de GFCI: Perform the GFCI test as described in Section 5.
  • Inspecció visual: Periodically inspect the circuit breaker for any signs of physical damage, discoloration, or loose connections. If any issues are observed, contact a qualified electrician.
  • Neteja: Keep the breaker and surrounding area clean and free of dust and debris. Do not use liquid cleaners directly on the breaker.

7. Solució De Problemes

ProblemaCausa possibleSolució
El trencador es desplaça amb freqüència.Overload, short circuit, or ground fault.Reduce load on the circuit. Check for damaged appliances or wiring. If it's a GFCI trip, check for ground faults in connected equipment. Contact an electrician if the problem persists.
Breaker does not reset after tripping.Persistent fault (overload, short circuit, or ground fault) or internal breaker damage.Ensure the handle is pushed fully to "OFF" before attempting to reset to "ON". If it still won't reset, a fault is likely present. Do not force the breaker. Contact a qualified electrician.
GFCI test button does not trip the breaker.Mecanisme GFCI defectuós.The breaker may be defective. It must be replaced by a qualified electrician.
No data in My Leviton app / Breaker not connecting.Network issue, app configuration error, or data hub issue.Ensure your Wi-Fi network is active and the Leviton data hub (if applicable) is connected. Check app settings and follow in-app troubleshooting guides.

For issues not covered here, contact Leviton customer support or a qualified electrician.

8. Especificacions

AtributDetall
MarcaLeviton
Número de modelLB260-GS
Valoració actual60 Amps
Nombre de pols2
Voltage120 / 240 VAC
Tipus d'interruptorGFCI (interruptor de circuit de falla a terra)
Trip TechnologyHydraulic Magnetic
Valoració d'interrupció10KA
Tipus de muntatgePanel Mounting (Plug-On)
Temperatura de funcionament-40 °C a 85 °C (-40 °F a 185 °F)
Dimensions4 x 2.5 x 3.9 polzades (aproximadament)
Pes13.6 unces
UPC078477815342

9. Garantia i Suport

Garantia:

This Leviton product is covered by a Garantia limitada de 10 anys. For full details regarding warranty terms and conditions, please refer to the official Leviton warranty statement available on their weblloc o contacteu amb el servei d'atenció al client.

Atenció al client:

For technical assistance, product information, or warranty claims, please contact Leviton customer support through their official weblloc web o la informació de contacte que s'inclou amb l'embalatge del producte.

You can visit the official Leviton website for more resources: www.leviton.com

Documents relacionats - LB260-GS

Preview Guia d'instal·lació del receptacle GFCI de muntatge en carril DIN de Leviton GFNT1-DIN/GFNT2-DIN
Guia completa per a la instal·lació i prova dels endolls GFCI per a muntatge en carril DIN GFNT1-DIN i GFNT2-DIN de Leviton, que inclou instruccions de cablejat, precaucions de seguretat i resolució de problemes.
Preview Leviton GFCI Outlet with USB Ports Installation and Operation Manual
Comprehensive guide for installing and operating Leviton GFCI Outlets with USB Ports, including wiring instructions, safety warnings, testing procedures, and warranty information.
Preview Leviton GFCI Receptacle Installation and Testing Guide
A comprehensive guide on how to install and test a Leviton SmartLock Pro GFCI Receptacle, including wiring instructions, safety precautions, and troubleshooting tips.
Preview Instal·lació i prova de la presa de corrent intel·ligent GFCI de Leviton: una guia completa
Instruccions pas a pas per instal·lar i provar les preses de corrent intel·ligents GFCI de Leviton (models D2GF1, D2GF2). Apreneu sobre la funcionalitat del GFCI, el cablejat, la resolució de problemes i les precaucions de seguretat.
Preview Leviton Load Center Phase Maps Installation Guide
This guide provides phase map illustrations to simplify the installation of the Leviton Whole Home Energy Monitor (LWHEM). It details where to terminate power wires and mount the Smart Mains Metering Accessory CTs for monitoring whole-home energy consumption.
Preview Leviton Load Center Enclosure Installation Instructions
Detailed installation instructions for Leviton Load Center Enclosures, models LP2xx, LP3xx, LP4xx, and LP6xx. Covers safety, knockout removal, mounting, wiring, branch circuit breaker installation, and cover fitting.