DSC PG9303

Manual d'instruccions del contacte de porta/finestra sense fil PowerG DSC PG9303

Model: PG9303

Introducció

This manual provides detailed instructions for the installation, operation, and maintenance of the DSC PG9303 Wireless PowerG Door/Window Contact. Please read this manual thoroughly before attempting to install or operate the device to ensure proper functionality and safety.

Producte acabatview

The DSC PG9303 is a wireless contact sensor designed to monitor the open/closed status of doors and windows. It consists of two main components: a sensor unit and a magnet.

Components

DSC PG9303 Wireless PowerG Door/Window Contact components

Image: The DSC PG9303 Wireless PowerG Door/Window Contact, showing the main sensor unit and the smaller magnet component. These two parts work together to detect when a door or window is opened or closed.

Especificacions

CaracterísticaDetall
Número de modelPG9303
FabricantDSC
Pes de l'article2.11 unces
Dimensions del paquet3.43 x 2.2 x 1.02 polzades
Font d'alimentacióBattery (CR2450, not included)
ConnectivitatWireless PowerG

Note: Batteries are not included with the product and must be purchased separately.

Configuració i instal·lació

1. Instal·lació de la bateria

  1. Carefully open the sensor unit casing.
  2. Insert a CR2450 battery, ensuring correct polarity (+/-).
  3. Close the sensor unit casing de manera segura.
  4. Important: If the device does not power on or pair, try removing and reinserting the battery to initiate pairing mode, as suggested by user experience.

2. Ubicació de muntatge

3. Muntatge del dispositiu

  1. Peel the protective backing from the adhesive pads on both the sensor unit and the magnet.
  2. Firmly press the sensor unit onto the chosen location on the frame.
  3. Align the magnet with the sensor unit and firmly press it onto the door or window. Ensure the alignment marks (if present) on both components face each other.
  4. Hold each component in place for at least 30 seconds to ensure strong adhesion.

4. Pairing with Your Alarm System

Refer to your specific alarm system's user manual for detailed instructions on how to add a new wireless PowerG device. Generally, the process involves:

  1. Accessing the programming menu on your alarm system's keypad.
  2. Selecting the option to add a new wireless zone or device.
  3. Activating the PG9303 sensor (e.g., by opening and closing the door/window it's installed on, or by removing and reinserting the battery if it's a new installation). The alarm system should detect the sensor.
  4. Assigning the sensor to a specific zone and configuring its settings (e.g., zone type, chime).
  5. Testing the sensor to confirm successful pairing and operation.

Instruccions de funcionament

Funcionament bàsic

The DSC PG9303 operates by detecting the presence or absence of its magnet. When the magnet is in close proximity to the sensor unit (door/window closed), the sensor is in a "closed" state. When the magnet moves away from the sensor unit (door/window opened), the sensor transitions to an "open" state, triggering a signal to your connected alarm system.

The response of your alarm system (e.g., chime, alarm activation) depends on the zone programming configured during installation.

Manteniment

Canvi de bateria

The PG9303 sensor is powered by a CR2450 lithium coin cell battery. When the battery level is low, your alarm system will typically indicate a low battery condition for the respective zone. To replace the battery:

  1. Disarm your alarm system to prevent false alarms during maintenance.
  2. Carefully open the sensor unit casing.
  3. Traieu la bateria CR2450 antiga.
  4. Insert a new CR2450 battery, observing correct polarity.
  5. Close the sensor unit casing de manera segura.
  6. Test the sensor by opening and closing the door/window to ensure it communicates with the alarm system.
  7. Elimineu les piles velles d'acord amb la normativa local.

Neteja

Clean the exterior of the sensor and magnet periodically with a soft, dry cloth. Avoid using abrasive cleaners, solvents, or excessive moisture, as these can damage the device.

Resolució de problemes

ProblemaPossible causa/solució
Sensor not pairing with alarm system.
  • Ensure the alarm system is in programming/pairing mode.
  • Verify the battery is correctly installed and has sufficient charge.
  • Try removing and reinserting the battery in the sensor to force it into pairing mode.
  • Check the distance between the sensor and the alarm panel; PowerG has excellent range, but extreme distances or heavy interference can affect communication.
Sensor not detecting open/close events.
  • Check the alignment and proximity of the sensor unit and magnet. The gap should not exceed half an inch.
  • Assegureu-vos que la bateria no estigui esgotada.
  • Verify the sensor is properly enrolled and enabled in your alarm system.
False alarms or intermittent signals.
  • Re-check the mounting and ensure the sensor and magnet are securely attached and do not shift.
  • Confirm the gap between the sensor and magnet is consistent and within the recommended range.
  • Environmental factors (e.g., extreme temperature changes causing door/window expansion/contraction) can sometimes affect alignment.

Informació de la garantia

For specific warranty details, please refer to the documentation provided with your purchase or contact DSC customer support directly. Warranty terms typically cover manufacturing defects for a specified period from the date of purchase.

Atenció al client

If you encounter issues not covered in this manual or require further assistance, please contact your alarm system installer or the manufacturer's customer support. Contact information can usually be found on the manufacturer's official website or in your alarm system's main documentation.

Documents relacionats - PG9303

Preview Instruccions d'instal·lació de PGx303 - Contacte de seguretat de Tyco DSC
Instruccions d'instal·lació detallades per al contacte magnètic de fuga supervisat Tyco DSC PGx303. Més informació sobre la configuració, el muntatge, el registre i les especificacions tècniques d'aquest sensor de seguretat sense fil PowerG.
Preview Manual d'instal·lació del convertidor amb cable a sense fil PG8WLSHW8 i PG9WLSHW8 IQ Hardwire PowerG
Aquest manual proporciona instruccions detallades per instal·lar, cablejar, configurar i solucionar problemes del convertidor de cablejat a sense fil Tyco/DSC PG8WLSHW8 i PG9WLSHW8 IQ Hardwire PowerG. Cobreix les especificacions tècniques, les directrius de seguretat i la informació de compliment per als integradors de sistemes d'alarma.
Preview WLS907 Series Wireless Door/Window Contact Installation Instructions
Comprehensive installation guide for the DSC WLS907 Series Wireless Door/Window Contact sensor, covering battery installation, mounting, external contacts, tamper switch, and enrollment.
Preview Guia de referència ràpida ERP per a dispositius DSC PowerSeries Neo PowerG
Guia de referència ràpida per a dispositius PowerG compatibles amb DSC PowerSeries Neo, que detalla la freqüència de 915 MHz, la variabilitat de potència i la potència de transmissió (ERP) en dBm per a diversos detectors, sirenes, claus i repetidors.
Preview Guia d'instal·lació del detector de moviment sense fil DSC PG4914/PG8914/PG9914 PowerG
Instruccions d'instal·lació per als detectors de moviment PIR sense fil DSC PG4914, PG8914 i PG9914 PowerG. Obteniu informació sobre les característiques, els procediments d'instal·lació, la configuració i la resolució de problemes del vostre sistema de seguretat DSC.
Preview Guia d'instal·lació de la rajola d'aigua PGPx986 PowerG+ amb detecció de congelació
Guia d'instal·lació per al sensor d'aigua Johnson Controls/DSC PGPx986 PowerG+ amb detecció de congelació. Apreneu a instal·lar, registrar i provar aquest sensor avançat de detecció de fuites d'aigua i congelació per a una seguretat millorada a la llar o a l'empresa.