AUTONICS CX6M-2P4

AUTONICS CX6M-2P4 Counter/Timer User Manual

1. Introducció

This manual provides essential information for the safe and efficient operation of the AUTONICS CX6M-2P4 Counter/Timer. The CX6M-2P4 is a versatile 6-digit LCD counter/timer unit, designed for industrial applications requiring precise counting and timing functions. It features 2 preset outputs, supports both PNP and NPN input types, and includes prescale value setting capabilities. The unit offers 2 SPDT (2c) relay outputs and 2 NPN open collector outputs, operating on a 100-240 VAC power supply.

2. Informació de seguretat

Read and understand all safety precautions before installing or operating the device. Failure to follow these instructions may result in injury or product damage.

3. Producte acabatview

The AUTONICS CX6M-2P4 is a compact and robust counter/timer designed for precise control in various industrial settings.

3.1. Característiques

3.2. Components

The unit consists of a front panel with an LCD display and control buttons, and a rear panel with terminal blocks for power, input, and output connections.

AUTONICS CX6M-2P4 Counter/Timer front view

Image showing the front panel of the AUTONICS CX6M-2P4 Counter/Timer, displaying the 6-digit LCD, control buttons, and overall dimensions.

4. Configuració

4.1. Muntatge

The CX6M-2P4 is designed for panel mounting. Cut a rectangular opening of 68x68mm (W x H) in the panel. Insert the unit from the front and secure it using the provided mounting brackets from the rear. Ensure a tight fit to prevent dust and moisture ingress.

4.2. Cablatge

Before wiring, ensure that the power supply is completely disconnected. Refer to the wiring diagram on the side of the unit or in the full product manual for detailed connections. Below are general guidelines:

5. Instruccions de funcionament

5.1. Funcionament bàsic

Once powered on, the unit will display the current count or time value. The front panel buttons allow for resetting the count, switching display modes, and accessing parameter settings.

5.2. Configuració de paràmetres

To configure the counter/timer, enter the parameter setting mode:

  1. Press and hold the MODE button for a few seconds until the display changes to the parameter setting menu.
  2. Use the UP/DOWN buttons to navigate through the parameters (e.g., preset values, input mode, prescale value, output mode).
  3. Press the MODE button briefly to select a parameter for editing.
  4. Use the UP/DOWN buttons to change the parameter value.
  5. Press the MODE button again to confirm the new value and move to the next parameter or exit the editing mode.
  6. To exit the parameter setting mode, navigate to the end of the menu or hold the MODE button again.

6. Manteniment

The AUTONICS CX6M-2P4 is designed for long-term, reliable operation with minimal maintenance. Follow these guidelines to ensure optimal performance:

7. Solució De Problemes

Consulteu la taula següent per veure els problemes habituals i les seves possibles solucions.

ProblemaCausa possibleSolució
La unitat no s'encén.No hi ha alimentació o cablejat incorrecte.Comproveu les connexions d'alimentació i assegureu-vos que el volum sigui correctetage (100-240 VAC).
Count/Time does not increment.Input sensor not connected, faulty, or incorrect input mode setting.Verify sensor wiring, check sensor functionality, and confirm input mode (PNP/NPN) in settings.
Output does not activate.Preset value not reached, output mode incorrect, or load wiring issue.Check preset values, verify output mode settings, and inspect load wiring.
La pantalla mostra el codi d'error.Internal error or specific fault condition.Refer to the full product manual for specific error code meanings. Power cycle the unit. If the error persists, contact support.

8. Especificacions

Technical specifications for the AUTONICS CX6M-2P4 Counter/Timer.

ParàmetreValor
ModelCX6M-2P4
MostraLCD de 6 dígits
Dimensions (W x H)72 mm x 72 mm
Tipus d'entradaPNP or NPN selectable
Preset Outputs2 (Relay SPDT (2c) 250VAC 3A, NPN Open Collector)
Font d'alimentació100-240 VAC
Pes1.1 lliures (aprox. 0.5 kg)

9. Garantia i Suport

AUTONICS products are manufactured under strict quality control. For warranty information, please refer to the warranty card included with your product or visit the official AUTONICS website. For technical support, service, or inquiries, please contact your local AUTONICS distributor or customer service center. Provide the model number (CX6M-2P4) when seeking assistance.

Documents relacionats - CX6M-2P4

Preview Autonics FX/FXH/FXL 시리즈 디지털 카운터/타이머 사양
Autonics FX, FXH, FXL 시리즈 디지털 카운터 및 타이머에 대한 상세 사양, 기능 및 배선도를 제공합니다. 입력/출력 모드, 작동 속도 및 설치를 다룹니다.
Preview Autonics CX Series LCD Display Counter/Timer Instruction Manual
Instruction manual for Autonics CX Series LCD Display Counter/Timer, covering models CX6S and CX6M. Provides details on specifications, connections, operations, function settings, and safety considerations.
Preview Autonics ATM Series Analog Timers Catalog
Comprehensive catalog detailing the Autonics ATM Series of miniature analog timers. Includes specifications, ordering information, features, dimensions, and pin arrangements for models ATM4-2, ATM4-5, and ATM4-6.
Preview Autonics TC Series Touch Switch Type Temperature Controllers Datasheet
Comprehensive datasheet for Autonics TC Series Touch Switch Type Temperature Controllers, detailing features, specifications, ordering information, dimensions, connection diagrams, functions, and error handling.
Preview Autonics CN-6000 Series: Isolated Converters Instruction Manual
Instruction manual for Autonics CN-6000 Series Isolated Converters, detailing specifications, ordering, unit descriptions, connections, safety, and programming for universal and pulse input models.
Preview Manual d'instruccions dels comptadors/temporitzadors digitals programables de la sèrie CT d'Autonics
Comprehensive instruction manual for Autonics CT Series programmable digital counters and timers, covering ordering, specifications, connections, parameter settings, and operation modes. Includes safety precautions and usage guidelines.