Apex 9C668001

Manual d'usuari del matalàs de pressió alternada amb baixa pèrdua d'aire Apex Medical Domus de 3-5"

Model: 9C668001

Introducció

The Apex Medical Domus 3-5" Low Air Loss Alternating Overlay Pressure Mattress is designed to provide pressure redistribution and comfort for patients, particularly those at medium risk of pressure injury. This system features two therapy modes: alternating mode for dynamic pressure relief and static mode for a stable surface. Its ventilated low air loss function helps manage moisture and heat, contributing to patient comfort and reducing the risk of skin breakdown.

Informació de seguretat

Always read and understand all instructions before operating the device. Failure to do so may result in injury or damage to the product.

Components

The Apex Medical Domus 3-5" system includes the following main components:

Apex Medical Domus 3-5 inch Low Air Loss Alternating Overlay Pressure Mattress and Pump System

Figura 1: Mésview of the Apex Medical Domus 3-5" Pressure Mattress and Pump System.

Configuració

  1. Prepara el llit: Place the mattress overlay directly on top of the existing mattress on a hospital or home bed. Ensure it is centered and lies flat.
  2. Posició de la bomba: Place the pump unit on a stable surface at the foot end of the bed, or hang it securely on the bed frame using the integrated hangers. Ensure it is easily accessible and not obstructed.
  3. Connecteu les mànegues d'aire: Connect the air hoses from the mattress to the corresponding ports on the pump unit. Ensure a secure and airtight connection.
  4. Connectar: Connecteu el cable d'alimentació de la bomba a una presa de corrent amb connexió a terra.
  5. Inflació inicial: Turn on the pump. The mattress will begin to inflate. Allow approximately 20-30 minutes for the mattress to fully inflate before placing a patient on it.
Dimensions of Apex Medical Domus 3-5 inch Pressure Mattress and Pump

Figure 2: Mattress and pump dimensions for proper setup. Mattress: 78.7" (L) x 35.4" (W) x 5" (H). Pump: 11.4" (L) x 7.3" (H) x 5" (W).

Instruccions de funcionament

Encès/Apagat

Locate the power switch on the pump unit. Flip the switch to the "ON" position to start the pump and inflate the mattress. Flip to "OFF" to turn off the unit.

Modes de teràpia

The Domus 3 offers two primary therapy modes:

Diagram showing alternating pressure redistribution cycle

Figure 3: Illustration of the alternating pressure redistribution system, showing one cycle of inflation and deflation.

Ajust de pressió

The pump unit features a variable pressure setting with a weight indicator. Adjust the pressure knob to select the appropriate firmness based on the patient's weight and comfort preference. Refer to the pump's display or markings for recommended settings.

Funció de baixa pèrdua d'aire

Air cells 3 through 11 are designed with a low air loss feature. This allows a small amount of air to escape through microscopic pores, wicking away moisture and heat from the patient's skin. This helps keep the patient comfortable and reduces the risk of skin maceration and shear forces.

Close-up of mattress showing low air loss feature

Figure 4: Visual representation of the low air loss feature, illustrating how air escapes to prevent skin maceration.

Manteniment

Cleaning the Mattress Cover

The Nylon/PU cover is water-resistant and vapor permeable. It can be removed for cleaning. Unzip the cover completely and follow these instructions:

Close-up of mattress cover zipper and material

Figure 5: Details of the zipper-all-around cover and the water-resistant Nylon/PU material.

Neteja de la unitat de la bomba

Wipe the exterior of the pump unit with a damp cloth and a mild, non-abrasive cleaner. Do not immerse the pump in water or spray liquids directly onto it.

Air Cell Replacement

Each of the 17 air cells is individually removable and replaceable. If an air cell is damaged, disconnect the mattress from the pump, deflate the mattress, and carefully remove the damaged cell. Insert a new cell and re-inflate the mattress.

Resolució de problemes

ProblemaCausa possibleSolució
Mattress not inflating or losing air
  • Pump not powered on
  • Hoses not securely connected
  • Leak in mattress or hose
  • Low pressure alarm activated
  • Ensure pump is plugged in and switched on.
  • Comproveu que totes les connexions de les mànegues estiguin ben ajustades.
  • Inspect mattress and hoses for visible damage. Replace damaged air cells if necessary.
  • Check for kinks in hoses or obstructions.
La bomba és sorollosa
  • Normal operation noise (should be ≤ 30dB(A))
  • Pump not on a stable surface
  • Problema intern
  • Assegureu-vos que la bomba estigui sobre una superfície plana i estable.
  • If noise is excessive or unusual, contact customer support.
Mattress too firm/soft
  • Ajust de pressió incorrecte
  • Patient weight not matched to setting
  • Adjust the pressure knob on the pump unit according to patient weight and comfort.

Especificacions

Apex Medical Domus 3-5 inch and 8 inch mattress height options

Figure 6: The Domus mattress is available in 5-inch and 8-inch height options. This manual pertains to the 5-inch model.

Garantia i Suport

Garantia: The Apex Medical Domus 3-5" Low Air Loss Alternating Overlay Pressure Mattress and its pump system come with a 1 anys de garantia des de la data de compra. Aquesta garantia cobreix defectes de fabricació i avaries en condicions d'ús normal.

Atenció al client: For technical assistance, troubleshooting not covered in this manual, or warranty claims, please contact Apex Medical customer support. Refer to the product packaging or the Apex Medical official weblloc per obtenir dades de contacte.

When contacting support, please have your product model number (9C668001) and date of purchase readily available.

Documents relacionats - 9C668001

Preview Guia ràpida del mode de proveïdor automàtic d'APEX XT
Una guia ràpida per a professionals mèdics sobre com utilitzar el dispositiu APEX XT Auto en mode proveïdor, incloent-hi la configuració de la navegació i el restabliment dels mesuradors de compliment.
Preview Manual d'instruccions del sistema APEX XT Auto CPAP
Manual d'instruccions complet per al sistema APEX XT Auto CPAP (model 9S-005720), que detalla la configuració, el funcionament, el manteniment, la resolució de problemes i les especificacions tècniques per al tractament de l'apnea obstructiva del son (AOS).
Preview Manual d'usuari de la bomba APEX VAC: Instruccions i guia de seguretat
Manual d'usuari complet per a la bomba APEX VAC, que detalla el funcionament, la seguretat, les especificacions tècniques i la resolució de problemes dels models VacPro, VacMaxi i VacPlus d'Apex Medical Corp.
Preview Manual del propietari del sistema de seguretat DESTINY
Aquest manual d'usuari del sistema de seguretat Apex DESTINY ofereix una guia completa sobre la instal·lació, el funcionament, els modes d'activació (ABAST, CASA, NIT), l'accés remot, les funcions de bypass i les funcions opcionals de domòtica.
Preview Manual d'instruccions de la cadira de massatge APEX-V2: guia de configuració, funcionament i manteniment
Manual d'instruccions complet per a la cadira de massatge APEX-V2, que cobreix les precaucions de seguretat, la instal·lació, el funcionament, la configuració, les especificacions, la resolució de problemes, la neteja i el manteniment. Apreneu a configurar i utilitzar la vostra cadira de massatge APEX-V2 de manera eficaç.
Preview Manual d'usuari del megàfon Apex MegaUSB
Manual d'usuari de l'Apex MegaUSB, un megàfon portàtil amb walkie-talkie integrat, amb so clar, múltiples opcions d'alimentació i instruccions d'ús essencials.