1. Introducció
This manual provides comprehensive instructions for the safe and effective operation, maintenance, and troubleshooting of the RS PRO RSDS 1052 DL+ Digital Storage Oscilloscope. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage or injury.
The RS PRO RSDS 1052 DL+ is a versatile 2-channel digital storage oscilloscope with a 50 MHz bandwidth, designed for precise signal analysis. It features a 7-inch TFT LCD display for clear waveform visualization and supports various measurement parameters and mathematical operations.
2. Informació de seguretat
Always adhere to the following safety precautions to prevent electric shock, fire, or damage to the instrument.
- Font d'alimentació: Ensure the oscilloscope is connected to a power source within the specified voltage range (100-240V AC, 50/60Hz).
- Posada a terra: The instrument must be properly grounded to prevent electric shock. Do not defeat the grounding plug.
- Medi ambient: Operate the oscilloscope in a dry, well-ventilated area, away from direct sunlight, high temperatures, and excessive dust.
- Sondes: Use only probes supplied or recommended by RS PRO. Ensure probes are correctly rated for the voltages mesura.
- Manteniment: Refer all servicing to qualified service personnel. Do not attempt to open the instrument casing unless explicitly instructed.
- Categoria de seguretat: This device is rated CAT I, CAT II. Observe all safety warnings on the device and in this manual.
3. Producte acabatview i Components
Aquesta secció ofereix un finalview of the RS PRO RSDS 1052 DL+ oscilloscope and its main components.

Figura 3.1: Frontal View of the Oscilloscope. This image shows the front panel of the RS PRO RSDS 1052 DL+ oscilloscope, highlighting the 7-inch TFT LCD display, control knobs, function buttons, and input connectors for channels 1 and 2. The screen displays a typical waveform and FFT analysis.

Figura 3.2: Angle View of the Oscilloscope. This image provides an angled perspective of the RS PRO RSDS 1052 DL+ oscilloscope, showcasing its compact design and integrated handle for portability. The side ventilation grilles are also visible.

Figura 3.3: posterior View of the Oscilloscope. This image displays the rear panel of the RS PRO RSDS 1052 DL+ oscilloscope, featuring the power input, USB device port, USB host port, LAN port, and Pass/Fail output. Safety warnings and product labels are also visible.

Figure 3.4: Oscilloscope Probe and Accessories. This image shows a passive oscilloscope probe (1:1/10:1) along with various accessories, including colored rings for channel identification and probe tip covers. These are essential for connecting signals to the oscilloscope.

Figure 3.5: Power Plugs and Probe Tip. This image displays an assortment of power plugs (EU, UK, US types) that may be included with the oscilloscope, along with a specialized probe tip. These ensure compatibility with various power outlets and provide versatility for measurements.
3.1 Accessoris inclosos
The RS PRO RSDS 1052 DL+ typically includes the following accessories:
- Passive Probe 1:1/10:1 (x2)
- Cable USB
- Guia d'inici ràpid
- Certificat de qualitat
- Cable d'alimentació (específic per a cada regió)
- CD (including User Manual and EasyScopeX software)
4. Configuració
4.1 Desembalatge i inspecció
- Carefully remove the oscilloscope and all accessories from the packaging.
- Inspect the instrument for any signs of physical damage during transit. If damage is found, contact your supplier immediately.
- Verify that all included accessories listed in Section 3.1 are present.
4.2 Connexió d'alimentació
- Assegureu-vos que l'interruptor d'alimentació del panell posterior estigui en la posició OFF.
- Connecteu el cable d'alimentació proporcionat a l'entrada de CA del panell posterior de l'oscil·loscopi.
- Plug the other end of the power cord into a grounded AC power outlet. The oscilloscope supports 100-240V AC, 50/60Hz.
4.3 Connexió i compensació de la sonda
- Connect the BNC connector of the passive probe to one of the input channels (CH1 or CH2) on the front panel.
- Attach the probe tip to the probe compensation output (usually a square wave test signal) on the front panel.
- Adjust the compensation trimmer on the probe until the displayed square wave is flat-topped, without overshoot or undershoot. This ensures accurate measurements.
5. Instruccions de funcionament
5.1 Funcionament bàsic
- Encès/apagat: Press the power button on the front panel to turn the oscilloscope on or off.
- Configuració automàtica: Premeu el botó Automàtic button to automatically adjust vertical, horizontal, and trigger settings for a stable waveform display.
- Controls verticals: Utilitza el VOLTS/DIV knob to adjust the vertical scale (voltage per division) and the POSICIÓ knob to move the waveform vertically.
- Controls horitzontals: Utilitza el SEC/DIV knob to adjust the horizontal scale (time per division) and the POSICIÓ knob to move the waveform horizontally.
- Controls de disparador: Ajusteu el NIVELL knob to set the trigger threshold. The trigger ensures a stable display of repetitive waveforms.
5.2 Funcions avançades
- Funcions de mesura: Premeu el botó Mesura button to access automatic measurement parameters such as Vpp, Vmax, Vmin, Freq, Period, etc.
- Funcions matemàtiques: Premeu el botó Matemàtiques button to perform mathematical operations on waveforms (e.g., Add, Subtract, Multiply, Divide, FFT).
- Emmagatzematge i retirada: Utilitza el Guardar/recuperar buttons to save waveform data, setups, or screenshots to internal memory or a USB drive.
- Connectivitat USB: Connect a USB drive to the front panel USB host port for data storage. Use the rear USB device port to connect the oscilloscope to a PC for data transfer and control via EasyScopeX software.
6. Manteniment
6.1 Neteja
- Desconnecteu el cable d'alimentació abans de netejar.
- Utilitzeu un suau, damp cloth with mild detergent to clean the exterior of the instrument.
- Do not use abrasive cleaners or solvents that may damage the plastic parts.
- Assegureu-vos que no entri líquid a l'instrument.
6.2 Calibració
The oscilloscope is factory calibrated. For optimal performance, periodic calibration by qualified personnel is recommended, typically every 12-24 months, depending on usage and environmental conditions.
6.3 Emmagatzematge
When not in use for extended periods, store the oscilloscope in a dry, dust-free environment, away from extreme temperatures and humidity.
7. Solució De Problemes
Aquesta secció ofereix solucions a problemes comuns que podeu trobar.
| Problema | Causa possible | Solució |
|---|---|---|
| Sense poder | Power cord disconnected; Power switch off; Blown fuse | Check power cord connection; Turn power switch on; Contact service for fuse replacement. |
| No es mostra cap forma d'ona | Input signal too small/large; Incorrect vertical/horizontal settings; Trigger not set correctly; Probe not connected | Adjust VOLTS/DIV and SEC/DIV; Use Auto Setup; Adjust trigger level; Ensure probe is connected and compensated. |
| Unstable waveform | Incorrect trigger settings; No trigger source selected | Adjust trigger level and mode; Select appropriate trigger source (e.g., CH1, CH2, Ext). |
| Forma d'ona distorsionada | Probe compensation incorrect; Probe damaged; Input overloaded | Perform probe compensation; Try a different probe; Check input signal ampla latitud. |
If the problem persists after attempting these solutions, please contact RS PRO customer support.
8. Especificacions
Key technical specifications for the RS PRO RSDS 1052 DL+ Digital Storage Oscilloscope:
- Canals analògics: 2
- Oscilloscope Type: Emmagatzematge digital
- Ample de banda: 50 MHz
- S en temps realampli Rate: Up to 500 MSa/s
- Profunditat de memòria: 32 Kpts
- Tipus de visualització: LCD TFT
- Mida de la pantalla: 7 polzades (800 x 480 píxels)
- Sensibilitat vertical: 2mV/div to 10V/div
- Time Base Range: 10ns/div a 50s/div
- Font d'alimentació: Mains operated (100-240V AC, 50/60Hz)
- Pes: 2.5 kg
- Categoria de seguretat: CAT I, CAT II
- Interfícies: RS232, USB Host, USB Device, LAN
9. Garantia i Suport
RS PRO products are manufactured to high standards and are typically covered by a manufacturer's warranty. Please refer to the warranty card included with your product or visit the official RS PRO weblloc web per obtenir informació detallada sobre els termes i condicions de la garantia.
For technical support, service, or inquiries regarding your RS PRO RSDS 1052 DL+ oscilloscope, please contact RS PRO customer service through their official channels. Contact information can usually be found on the RS PRO website or in the documentation provided with the product.
RS PRO Official Weblloc: https://uk.rs-online.com/web/