Introducció
This manual provides detailed instructions for the installation, operation, and maintenance of the DROK Bidirectional Volt Amp Meter, Model 200536FBA. This 7-in-1 monitor is designed to measure DC voltage, current, power, battery capacity, amp-hour, watt-hour, and time, featuring a clear color LCD display and a Hall sensor for non-contact current measurement.
Característiques del producte
- Mesura 7 en 1: Simultaneously displays DC voltage (0-90V), current (0-300A), power, battery capacity, amp-hour, watt-hour, and time on a 1.8-inch LCD color screen.
- Bidirectional Ammeter: Detects current flow in both charging and discharging directions without requiring changes to wiring.
- Comprehensive Protection Functions: Includes Over-Voltage Protection (OVP), Over-Current Protection (OCP), Over-Power Protection (OPP), Low-Voltage Protection (LOP), Over-Charge Protection (OAH), and Over-Time Protection (OFT).
- Funció de memòria: AH power-off memorized function retains data.
- Reset and Calibration: Features time and AH reset functions, along with a calibration capability for accurate readings.
- Control de la pantalla: LCD screen can be switched off automatically or manually.
- Control de sortida: Connects to a relay (not included) for enabling/disabling output via a control button.
Contingut del paquet
Verifiqueu que tots els elements siguin presents al paquet:
- 1x Charge-Discharge Monitor (Display Unit)
- 1x Hall Sensor (Current Sensor)
- 1x 50cm Shielding Wire (for connecting display to sensor)

Image: The complete package contents, showing the display unit, Hall sensor, and the included shielding wire.
Especificacions
| Paràmetre | Valor |
|---|---|
| Paràmetres de mesura | Voltage, Current, Power, Battery Capacity, Amp-Hour, Watt-Hour, Time |
| Voltage Interval de mesura | DC 0-90V |
| Interval de mesura actual | DC 0-300A |
| Voltage Precisió de la mesura | ± 2% ± 5 dígits |
| Precisió de la mesura actual | ± 3% ± 5 dígits |
| Resolució de visualització | 0.1A, 0.01V, 0.01AH, 0.01H (1 min) |
| Taxa de mesura | 5 vegades / segon |
| Mostra | 1.8 inch LCD Color Screen |
| Meter Overall Dimension | 79 x 43 x 26 mm (3.11 x 1.69 x 1.02 polzades) |
| Meter Opening Hole Size | 76.5 x 39.2 mm (3.01 x 1.54 polzades) |
| Mida del sensor Hall | 57 x 32 x 50mm (2.24 x 1.26 x 1.97 inch) (with screw and copper pillars) |
| Hall Sensor Hole Diameter | 20 mm (0.79 polzades) |
| Més de voltage Protecció (OVP) | 0.01V-90V |
| Protecció contra sobrecorrent (OCP) | 0.1-100A |
| Protecció contra sobrealimentació (OPP) | 0.01 W-9.99 kW |
| Volum baixtage Protection (LOP) | 0.01V-90V |
| Over-Charge Protection (OAH) | 0.01AH-9999AH |
| Over-Time Protection (OFT) | 1 min-99 hora 59 min |

Image: Physical dimensions of the display unit and the Hall sensor for installation planning.
Configuració i instal·lació
Proper wiring is crucial for accurate measurements and safe operation. The Hall sensor measures current by passing the load wire through its central hole. The display unit requires a power supply (DC 10-60V) and connects to the Hall sensor via the provided shielding wire.

Image: Three common wiring configurations for the meter, showing connections to battery, load, and optional relay.
Wiring Configuration 1: Basic Monitoring (Self-Powered)
In this configuration, the meter is powered directly from the battery being monitored. This is suitable for systems where the battery voltage is within the meter's operating range (10-60V).
- Connect the positive terminal of the battery to the 'Bat+' terminal on the Hall sensor.
- Connect the negative terminal of the battery to the 'Bat-' terminal on the Hall sensor.
- Passa el negatiu load wire through the central hole of the Hall sensor. Ensure the direction of current flow through the sensor matches the arrow on the sensor for correct bidirectional readings.
- Connect the display unit to the Hall sensor using the provided 50cm shielding wire.
- Ensure the jumper cap on the Hall sensor is placed to select the self-powered mode (typically labeled '10-60V' or similar, check the sensor board for exact markings).
Wiring Configuration 2: External Power Supply
Use this configuration when the battery voltage is outside the meter's operating range (e.g., 0-10V or above 60V) or if you prefer a separate power source for the meter.
- Connect the positive terminal of the battery to the 'Bat+' terminal on the Hall sensor.
- Connect the negative terminal of the battery to the 'Bat-' terminal on the Hall sensor.
- Passa el negatiu load wire through the central hole of the Hall sensor.
- Connect the display unit to the Hall sensor using the provided 50cm shielding wire.
- Connect an external DC power supply (10-60V) to the 'Vext+' and 'Vext-' terminals on the Hall sensor.
- Remove the jumper cap from the Hall sensor to enable external power mode.
Wiring Configuration 3: With Relay for Output Control
This setup allows the meter to control an external relay (not included) based on configured protection parameters (e.g., over-current, low-voltagi).
- Follow either Configuration 1 or 2 for basic power and measurement connections.
- Connect the relay's control terminals to the 'Relay+' and 'Relay-' terminals on the Hall sensor.
- Ensure the jumper cap is set correctly for the chosen power mode (self-powered or external).
- The meter's output control button can then be used to enable/disable the relay, or the relay can be triggered automatically by protection settings.
Instruccions de funcionament
The DROK Volt Amp Meter features a user-friendly interface with a color LCD and three control buttons: Up, OK, and Down.

Image: The main display interface, showing voltage, current, capacity, power, time, and protection status indicators.
Visualització finalitzadaview
The 1.8-inch color LCD simultaneously displays:
- Voltage (V): Top left, large font.
- Corrent (A): Below voltage, large font.
- Battery Capacity (%): Graphical bar and percentage.
- Amp-Hour (AH): Accumulated charge/discharge.
- Watt-Hour (WH): Accumulated energy.
- Potència (W): Potència instantània.
- Time (H): Temps transcorregut.
- Indicadors de protecció: OVP, OPP, OCP, OFT, OAH, LOP (Over-Voltage, Over-Power, Over-Current, Over-Time, Over-Charge, Low-Voltage Protecció).
Funcions del botó
- Botó de fletxa amunt: Navigates upwards through menu options or increases values during settings.
- Botó de fletxa avall: Navigates downwards through menu options or decreases values during settings.
- Botó D'acord: Enters menu, confirms selections, or toggles display modes (e.g., battery graph). Press and hold to access certain functions or calibration mode.
Resetting AH and Time
To reset accumulated Amp-Hours (AH) and Time, navigate to the relevant display screen using the arrow buttons. Press and hold the OK button until the values reset. This is useful for monitoring specific charge/discharge cycles.
Procediment de calibratge
For optimal accuracy, calibration may be required. Follow these steps carefully:
- Entra al mode de calibratge: While the device is powered off, press and hold the OK button. While holding OK, switch the power to the device ON. Release the OK button as soon as the display illuminates.
- Navigation in Calibration Mode: In calibration mode, press the OK button to move from one menu item to the next. Use the Up i Avall arrow keys to adjust values.
- Zero Current Calibration: Before calibrating current readings, ensure no current is flowing through the Hall sensor. Switch off all loads. Press OK until the "0.0 A" option is selected, then press the Avall arrow once to zero out the current reading.
- Positive Current Calibration (+A): To calibrate current in the charging direction, ensure current is flowing from the charging source into your battery. Press OK until the "+A" option is selected, then use the arrow keys to adjust the reading to match a known accurate current measurement.
- Negative Current Calibration (-A): To calibrate current in the discharging direction, ensure current is flowing out of your battery into your loads. Press OK until the "-A" option is selected, then use the arrow keys to adjust the reading to match a known accurate current measurement.
- Desa la configuració: After completing all calibrations, navigate the cursor to the "Save" option using the OK button. Select "Save" to store your settings.
- Exit Calibration Mode: To exit calibration mode, simply switch the power to the unit OFF, then ON again.
Funcions de protecció
The meter includes several programmable protection functions to safeguard your system:
- OVP (Over-Voltage Protecció): Configurable from 0.01V to 90V. Triggers when voltage exceeds the set limit.
- OCP (Over-Current Protection): Configurable from 0.1A to 100A. Triggers when current exceeds the set limit.
- OPP (Over-Power Protection): Configurable from 0.01W to 9.99KW. Triggers when power consumption exceeds the set limit.
- LOP (Low-Voltage Protecció): Configurable from 0.01V to 90V. Triggers when voltage drops below the set limit.
- OAH (Over-Charge Protection): Configurable from 0.01AH to 9999AH. Triggers when accumulated charge exceeds the set limit.
- OFT (Over-Time Protection): Configurable from 1 minute to 99 hours 59 minutes. Triggers when operation time exceeds the set limit.
When a protection limit is reached, the meter can activate an external relay (if connected) to disconnect the load or charging source.
Altres Funcions
- AH Power Off Memorized Function: Retains accumulated Amp-Hour data even after power loss.
- LCD Screen Auto/Manual Switch Off: The display can be configured to turn off automatically after a period of inactivity or can be manually toggled.
Manteniment
The DROK Bidirectional Volt Amp Meter is designed for durability and requires minimal maintenance.
- Neteja: Feu servir un drap suau i sec per netejar la pantalla iasing. Eviteu netejadors o dissolvents abrasius.
- Condicions ambientals: Operate the meter within its specified temperature and humidity ranges. Avoid exposure to extreme temperatures, direct sunlight, or moisture.
- Inspecció del cablejat: Comproveu periòdicament totes les connexions del cablejat per comprovar si estan ben ajustades i si hi ha signes de desgast o corrosió.
Resolució de problemes
- Sense pantalla/alimentació:
- Check power connections to the Hall sensor.
- Assegureu-vos que la font d'alimentació voltage està dins del rang de 10-60 V.
- Verify the jumper cap setting for self-powered or external power mode.
- Check the shielding wire connection between the sensor and the display.
- Incorrect Current Readings:
- Ensure the load wire passes correctly through the Hall sensor's central hole.
- Verify the direction of current flow relative to the arrow on the Hall sensor.
- Perform a current calibration as described in the "Operating Instructions" section.
- If monitoring both charging and discharging, ensure only the main battery wire (or the wire carrying the net current) passes through the sensor. Incorrect wiring can lead to inaccurate bidirectional readings.
- Vol inexactetage Lectures:
- Consulta voltage connections to the Hall sensor.
- Assegureu-vos que les connexions siguin segures i no presentin corrosió.
- Protection Function Not Triggering:
- Verify that the protection limits are set correctly in the meter's menu.
- Ensure the external relay (if used) is correctly wired and functional.
Garantia i Suport
Specific warranty information for the DROK Bidirectional Volt Amp Meter (Model 200536FBA) is not provided in this manual. For warranty claims, technical support, or further assistance, please refer to the product packaging, the seller's website, or contact DROK customer service directly.