C-LOGIC C-Logic 520

C-LOGIC 520 Digital Multimeter User Manual

Comprehensive guide for the C-LOGIC 520 Digital Multimeter, covering setup, operation, maintenance, and specifications.

1. Introducció

Welcome to the user manual for the Multímetre digital C-LOGIC 520. This device is designed for accurate measurement of AC/DC Voltage, DC Current, and Resistance, featuring a 2000-count display. It also includes continuity buzzer, low battery display, and battery testing functions for 1.5V, 9V, and 12V batteries. Please read this manual thoroughly before use to ensure safe and proper operation.

C-LOGIC 520 Digital Multimeter front view

Figura 1: Frontal view of the C-LOGIC 520 Digital Multimeter, showing the display, rotary switch, and input jacks.

2. Informació de seguretat

Always adhere to safety precautions when using electrical testing equipment. This device is rated CAT III 600V. Failure to follow safety guidelines can result in injury or damage to the multimeter.

3. Característiques del producte

The C-LOGIC 520 Digital Multimeter offers a range of features for various electrical measurements:

User holding C-LOGIC 520 Digital Multimeter measuring voltage

Figure 2: A user wearing protective gloves, holding the C-LOGIC 520 Digital Multimeter while performing a measurement on an electrical outlet.

4. Configuració

4.1 Desembalatge

Carefully remove the multimeter and its accessories from the packaging. Verify that all components are present:

4.2 Instal·lació de la bateria

The C-LOGIC 520 Digital Multimeter requires a 9V battery for operation. To install or replace the battery:

  1. Assegureu-vos que el multímetre estigui encès OFF.
  2. Localitzeu la tapa del compartiment de la bateria a la part posterior de la unitat.
  3. Descargoleu el(s) cargol(s) de subjecció i retireu la coberta amb cura.
  4. Connect the 9V battery to the battery clip, observing correct polarity (+ to + and - to -).
  5. Col·loqueu la bateria al compartiment i torneu a col·locar la tapa, fixant-la amb el(s) cargol(s).

4.3 Connexió dels cables de prova

Always connect the black test lead to the "COM" (Common) input jack. Connect the red test lead to the appropriate input jack based on the measurement you intend to perform:

5. Instruccions de funcionament

Before taking any measurement, ensure the multimeter is set to the correct function and range. Incorrect settings can damage the device or the circuit being tested.

5.1 Mesurar AC/DC Voltage

  1. Connect the black test lead to the "COM" jack and the red test lead to the "VΩmA" jack.
  2. Turn the rotary switch to the desired ACV (V~) or DCV (V-) range (e.g., 200V, 600V). If the voltage is unknown, start with the highest range.
  3. Connecteu les sondes de prova en paral·lel al circuit o component que voleu mesurar.
  4. Llegeix el voltage valor a la pantalla.
User measuring voltage with C-LOGIC 520 Digital Multimeter

Figure 3: A user wearing protective gloves, using the C-LOGIC 520 Digital Multimeter to measure voltage d'una presa de corrent.

5.2 Measuring DC Current (Ampera)

CAUTION: Never connect the multimeter in parallel to a voltagfont d'alimentació quan es mesura el corrent. Connecteu-ho sempre en sèrie amb la càrrega.

  1. Connect the black test lead to the "COM" jack.
  2. For currents up to 200mA, connect the red test lead to the "VΩmA" jack. For currents up to 10A, connect the red test lead to the "10A" jack.
  3. Turn the rotary switch to the appropriate DCA (A-) range (e.g., 200mA, 10A).
  4. Open the circuit where you want to measure current and connect the multimeter in series.
  5. Llegiu el valor actual a la pantalla.

5.3 Measuring Resistance (Ohms)

CAUTION: Ensure the circuit is de-energized before measuring resistance. Do not measure resistance on live circuits.

  1. Connect the black test lead to the "COM" jack and the red test lead to the "VΩmA" jack.
  2. Turn the rotary switch to the desired Resistance (Ω) range (e.g., 200Ω, 2MΩ).
  3. Connect the test probes across the component whose resistance you want to measure.
  4. Llegiu el valor de resistència a la pantalla.

5.4 Prova de continuïtat

  1. Connect the black test lead to the "COM" jack and the red test lead to the "VΩmA" jack.
  2. Turn the rotary switch to the continuity (•))) position.
  3. Touch the test probes to the two points of the circuit you want to test for continuity.
  4. Un bip audible indica continuïtat (baixa resistència). La pantalla mostrarà el valor de la resistència.

5.5 Prova de díodes

  1. Connect the black test lead to the "COM" jack and the red test lead to the "VΩmA" jack.
  2. Turn the rotary switch to the diode (►|) position.
  3. Connecteu la sonda vermella a l'ànode i la sonda negra al càtode del díode.
  4. La pantalla mostrarà el volum d'avançtage drop. Reverse the probes; the display should show "OL" (Overload) for a good diode.

5.6 Battery Test (1.5V, 9V, 12V)

  1. Connect the black test lead to the "COM" jack and the red test lead to the "VΩmA" jack.
  2. Turn the rotary switch to the desired battery test range (1.5V, 9V, or 12V).
  3. Connect the red probe to the positive (+) terminal of the battery and the black probe to the negative (-) terminal.
  4. Llegeix el vol de la bateriatage a la pantalla.

5.7 Funció de retenció de dades

Premeu el botó "HOLD" per congelar la lectura actual a la pantalla. Torneu-lo a prémer per alliberar la retenció i reprendre les lectures en directe.

6. Manteniment

6.1 Neteja

To clean the multimeter, use a soft, slightly damp cloth and a mild detergent. Do not use abrasives, solvents, or harsh chemicals. Ensure the device is completely dry before use or storage.

6.2 Substitució de la bateria

When the low battery indicator (LBD) appears on the display, it is time to replace the 9V battery. Follow the steps outlined in the "Battery Installation" section (4.2) under Setup.

6.3 Canvi de fusibles

The multimeter is protected by internal fuses, typically for the current measurement ranges. If the current measurement function stops working, the fuse may need replacement. Refer to the specifications section (7.0) for fuse ratings. Fuse replacement should only be performed by qualified personnel.

WARNING: Disconnect test leads from all circuits and turn off the multimeter before opening the case for fuse replacement to avoid electric shock.

7. Solució De Problemes

Taula 1: Problemes comuns i solucions
ProblemaCausa possibleSolució
Sense pantalla o pantalla tènueBateria baixa o baixaSubstituïu la bateria de 9V.
Es mostra "OL" (sobrecàrrega)Measurement exceeds selected range or maximum input.Select a higher range or verify the input is within the multimeter's limits.
Lectures incorrectesIncorrect function/range selected; poor test lead connection; damaged test leads.Verify rotary switch setting; ensure test leads are firmly connected; inspect and replace damaged leads.
La mesura de corrent no funcionaFusible cremat.Replace the internal fuse (refer to fuse specifications).
Continuity buzzer always on or offInternal fault or incorrect usage.Ensure probes are not shorted when testing; if problem persists, contact support.

8. Especificacions

Table 2: C-LOGIC 520 Digital Multimeter Specifications
ParàmetreValor
Mostra2000 recomptes
DC Voltage (V-)Ranges: 200mV, 2V, 20V, 200V, 600V; Max: 600V
Vol. ACtage (V~)Ranges: 200V, 600V; Max: 600V
Corrent continu (A-)Ranges: 200µA, 2mA, 20mA, 200mA, 10A; Max: 10A
Resistència (Ω)Ranges: 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ; Max: 2MΩ
Prova de díodeObert Voltage 3.0V
Buzzer de continuïtatAudible indication for resistance <50Ω
Retenció de dades
Low Battery Display (LBD)
Prova de bateria1.5 V, 9 V, 12 V
Font d'alimentació1x 9V (6F22 or NEDA 1604) Battery
Dimensions del producte (L x A x A)14.73 x 7.37 x 4.98 cm (5.8 x 2.9 x 1.96 polzades)
Pes del producte232 g (0.51 lliures)
Classificació de seguretatCAT III 600V
CertificacionsRoHS, CE, ETL
C-LOGIC 520 Digital Multimeter specifications and features table

Figure 4: Detailed specifications and features table for the C-LOGIC 520 Digital Multimeter, as provided by the manufacturer.

9. Garantia i Suport

For warranty information or technical support regarding your C-LOGIC 520 Digital Multimeter, please refer to the contact information provided with your purchase documentation or visit the official C-LOGIC weblloc web. Conserveu el rebut de compra com a comprovant de compra per a reclamacions de garantia.

For general inquiries, troubleshooting not covered in this manual, or service requests, please contact C-LOGIC customer service through their official channels.

Documents relacionats - C-Logic 520

Preview C-LOGIC 520 Digital Multimeter User Manual and Specifications
Detailed user manual for the C-LOGIC 520 Digital Multimeter, covering its features, safety precautions, operating instructions, technical specifications, and maintenance procedures.
Preview C-LOGIC 410-TC Programmable Digital Thermostat User Manual
Detailed instructions and technical specifications for the C-LOGIC 410-TC programmable digital thermostat, covering installation, operation, settings, and troubleshooting for heating and cooling control.
Preview C-LOGIC 2021 Catalogue: Electrical Test Instruments, Energy Saving, and Installation Products
Explore the comprehensive C-LOGIC 2021 Catalogue, featuring a wide range of electrical test and measurement instruments, energy-saving solutions, and installation tools. Discover multimeters, clamp meters, detectors, thermostats, and more from C-LOGIC and its associated brands.
Preview Guia d'inici ràpid del multímetre digital tipus bolígraf MASTECH MS8211D
Una guia d'inici ràpid per al multímetre digital tipus bolígraf MASTECH MS8211D, que proporciona informació essencial de seguretat, especificacions tècniques i instruccions bàsiques de funcionament per a vol.tage, proves de corrent, resistència i lògica.
Preview Manual d'usuari del multímetre digital ZOTEK ZT-Y
Manual d'usuari del multímetre digital ZOTEK ZT-Y, que cobreix les seves característiques, funcions, mesures, manteniment i especificacions.