Vertiv VP53100

Manual d'instruccions de la PDU de rack commutada Vertiv Geist VP53100

Model: VP53100

1. Introducció

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Vertiv Geist Switched Rack Power Distribution Unit (PDU) model VP53100. Please read this manual thoroughly before using the product and retain it for future reference.

The Vertiv Geist Switched Rack PDU VP53100 is a 1U horizontal PDU designed for rack environments, featuring 30A, 208V/240V input, and (12) combination C13/C19 outlets. It includes unit-level monitoring and switched outlet capabilities for advanced power management.

2. Informació de seguretat

Observeu les següents precaucions de seguretat per evitar lesions i danys a l'equip:

  • Ensure the PDU is installed by qualified personnel in accordance with all local and national electrical codes.
  • Do not operate the PDU in wet or excessively humid environments.
  • Do not attempt to open or modify the PDU. There are no user-serviceable parts inside.
  • Connect the PDU only to a properly grounded power source.
  • Ensure the total current draw of connected equipment does not exceed the PDU's maximum rated current (30A).
  • Desconnecteu sempre l'alimentació abans de realitzar qualsevol procediment de manteniment o instal·lació.

3. Producte acabatview

The Vertiv Geist Switched Rack PDU VP53100 provides reliable power distribution and advanced monitoring features for your data center equipment. Key components include:

  • Cable d'alimentació d'entrada: 10ft / 3m power cord with NEMA L6-30P plug.
  • Receptacles de sortida: (12) Combination C13/C19 outlets.
  • Disjuntors: Two circuit breakers (Circuit 1 and Circuit 2) for overcurrent protection.
  • Interfície de xarxa: For remote monitoring and control.
  • Visualització local: Digital display for local power metrics.
Davant view of the Vertiv Geist Switched Rack PDU VP53100, showing circuit breakers, network ports, and local display.

Figura 3.1: Frontal view of the Vertiv Geist Switched Rack PDU VP53100, showing the circuit breakers, network ports, and local display.

posterior view of the Vertiv Geist Switched Rack PDU VP53100, illustrating the (12) combination C13/C19 outlets.

Figura 3.2: posterior view of the Vertiv Geist Switched Rack PDU VP53100, illustrating the (12) combination C13/C19 outlets.

4. Configuració

  1. Muntatge: Install the PDU horizontally in a standard 19-inch rack using the provided mounting hardware. Ensure adequate airflow around the unit.
  2. Connexió d'alimentació: Connect the PDU's NEMA L6-30P input plug to a dedicated 30A, 208V/240V power source. Verify the power source is properly grounded.
  3. Connexió d'equips: Connect your IT equipment power cords to the PDU's C13/C19 outlets. Distribute the load evenly across the two circuits (Circuit 1 and Circuit 2) to prevent overloading.
  4. Connexió de xarxa (opcional): For remote monitoring and control, connect an Ethernet cable from the PDU's network port to your network switch. Refer to the network configuration guide for IP address setup.
  5. Encès: Once all connections are secure, switch on the circuit breakers on the front of the PDU. The local display should illuminate, indicating power is supplied.

5. Instruccions de funcionament

The Vertiv Geist Switched Rack PDU allows for local and remote management of power to connected devices.

5.1 Funcionament local

  • Visualització local: The front panel display shows real-time power metrics such as current (Amps), voltage (Volts), and power (kW) for the entire unit.
  • Disjuntors: Use the circuit breakers to manually switch power on or off for the respective circuits. In case of an overload, a breaker will trip, disconnecting power to its circuit. Reset by switching it back to the 'ON' position after reducing the load.

5.2 Remote Operation (Networked Units)

For units connected to a network, access the PDU's web interface or management software for advanced features:

  • Outlet Switching: Individually switch outlets on or off remotely.
  • Monitorització de potència: View detailed power consumption data per outlet or per circuit.
  • Alertes i notificacions: Configure thresholds for current, voltage, and power to receive alerts via email or SNMP when limits are exceeded.
  • Programació: Schedule power cycling for connected equipment.

6. Manteniment

The Vertiv Geist Switched Rack PDU requires minimal maintenance. Follow these guidelines:

  • Inspecció periòdica: Periodically inspect the PDU, power cords, and connected equipment for any signs of damage, wear, or loose connections.
  • Neteja: Keep the PDU clean and free of dust. Use a dry, soft cloth for cleaning. Do not use liquid cleaners or solvents.
  • Actualitzacions de firmware: Comproveu el del fabricant website for available firmware updates to ensure optimal performance and security.

7. Solució De Problemes

ProblemaCausa possibleSolució
No power to PDUInput power cord disconnected; upstream power failure; PDU circuit breaker tripped.Check power cord connection; verify upstream power source; reset PDU circuit breaker.
No hi ha alimentació al dispositiu connectatDevice power cord disconnected; PDU outlet switched off; PDU circuit breaker tripped.Check device power cord; verify outlet status (local/remote); reset PDU circuit breaker.
Network access failureEthernet cable disconnected; incorrect IP configuration; network issue.Verify Ethernet cable connection; check IP settings; consult network administrator.
Overload indication/Circuit breaker trips repeatedlyTotal load exceeds circuit capacity.Reduce the number of connected devices or redistribute load across circuits.

8. Especificacions

CaracterísticaDetall
Número de modelVP53100
Tipus PDUSwitched, Unit Level Monitoring EC
Entrada Voltage208V / 240V
Corrent d'entrada30A
Endoll d'entradaNEMA L6-30P
Receptacles de sortida(12) Combination C13/C19
FaseFase única
Factor de formaMuntatge en rack horitzontal d'1U
Capacitat de potència4.9 kW
Longitud del cable d'alimentació10 peus / 3 m
Dimensions (paquet)23 x 19 x 5 polzades
Pes de l'article14 lliures
FabricantVERTIU

9. Assistència i garantia

For technical assistance, product support, or warranty information, please contact Vertiv customer service. Refer to the official Vertiv weblloc web per obtenir les dades de contacte i els termes de garantia més actualitzats aplicables a la vostra regió.

Recursos en línia: www.vertiv.com

Documents relacionats - VP53100

Preview Geist™ Intelligent Rack PDU Installer/User Guide - Vertiv
Comprehensive installer and user guide for Vertiv's Geist™ Intelligent Rack PDU, covering installation, setup, network configuration, and advanced features for data center environments.
Preview Vertiv SmartRow 2 Infrastructure Solution Installer/User Guide
This comprehensive guide provides detailed instructions for the installation, operation, and maintenance of the Vertiv SmartRow 2 Infrastructure Solution. It covers system overview, features, safety instructions, power management, network configuration, and troubleshooting.
Preview Vertiv CoolChip CDU 100 Operation and Maintenance Guide
This guide provides comprehensive information on the operation and maintenance of the Vertiv CoolChip CDU 100, a coolant distribution unit designed for high-density IT equipment cooling. It covers safety instructions, product description, agency approvals, operation procedures, maintenance guidelines, and troubleshooting.
Preview Vertiv Geist Watchdog 100 Installer/User Guide
Comprehensive guide for installing and using the Vertiv Geist Watchdog 100 environmental monitor, covering setup, network configuration, web interface, sensors, alarms, and safety information.
Preview Manual d'usuari de l'armari de bateries externes modulars Liebert APM2
Manual d'usuari de l'armari de bateries externes modulars Vertiv Liebert APM2, que cobreix la instal·lació, la seguretat, les especificacions i el manteniment.
Preview Liebert EXM Distribution Cabinet User Manual - Vertiv
User manual for the Vertiv Liebert EXM Distribution Cabinet, covering installation, operation, maintenance, and specifications for 50-250kVA, 3-phase, 60Hz models.