1. Introducció
This manual provides essential instructions for the safe and efficient operation of your Kamoer KPAS-100 Peristaltic Pump Stepper Motor. Please read this manual thoroughly before installation and use to ensure proper function and longevity of the device. The Kamoer KPAS-100 is designed for precise fluid transfer in various applications, utilizing a stepper motor for adjustable speed and high accuracy.
2. Informació de seguretat
Observe the following safety precautions to prevent injury and damage to the pump:
- Assegureu-vos que la font d'alimentació coincideixi amb el volum de la bombatage requirements (DC 24V).
- Do not operate the pump with damaged tubing or components.
- Eviteu el contacte amb les peces mòbils durant el funcionament.
- Desconnecteu l'alimentació abans de realitzar qualsevol manteniment o resolució de problemes.
- Use appropriate personal protective equipment when handling chemicals.
- This pump is designed for specific fluid transfer; do not use it for purposes other than its intended application.
3. Producte acabatview
The Kamoer KPAS-100 is a compact peristaltic pump driven by a 24V stepper motor, offering precise control over fluid flow. Its design incorporates a durable Pharmed BPT tube for extended service life and chemical resistance.
3.1 Característiques clau
- Voltage: DC 24V
- Caudal: 110 ml/min
- Velocitat: 350 rpm
- Material del tub: Pharmed BPT (3.2mm ID × 6.4mm OD)
- Rotor: 3 rotors
- Temperatura de funcionament: 0 ~ 40 ℃
- Humitat relativa: <80%
- Tube Service Life: >1000 hores
- Suitable for viscous and non-viscous liquids.
- High precision stepper motor.

Figura 1: Kamoer KPAS-100 Peristaltic Pump Stepper Motor. This image shows the compact design of the pump with its blue transparent pump head and integrated stepper motor.
4. Especificacions
| Paràmetre | Valor |
|---|---|
| Número de model | KPAS100 |
| Voltage | DC 24V |
| Caudal | 110 ml/min |
| Velocitat | 350 rpm |
| Pharmed BPT Tube ID × OD | 3.2mm × 6.4mm |
| Number of Rotors | 3 |
| Temperatura de treball | 0 ~ 40 ℃ |
| Humitat relativa | <80% |
| Tube Service Life | >1000 hores |
| Tube Operating Temperature Range | -51 ℃ ~ 132 ℃ |
| Dimensions del paquet | 5.67 x 4.76 x 3.5 polzades |
| Pes | 15.84 unces |

Figura 2: Dimensional drawing of the Kamoer KPAS-100 pump. This diagram provides key measurements of the pump unit, including length, width, and height, useful for installation planning.
5. Configuració
5.1 Muntatge
Securely mount the pump in a stable location, ensuring adequate ventilation and clearance for tubing connections. Refer to the dimensional drawing in Section 4 for mounting considerations.
5.2 Tubing Connection
- Connect the inlet tubing to the fluid source and the outlet tubing to the destination.
- Assegureu-vos que totes les connexions estiguin ben fixades per evitar fuites.
- Verify that the tubing is not kinked or obstructed.
5.3 Cablejat elèctric
The KPAS-100 uses a stepper motor and requires a compatible stepper motor control board for operation and speed adjustment. Connect the motor wires to your control board according to the pinout diagram. Incorrect wiring can damage the motor or control board.

Figura 3: Stepper motor wiring diagram for the Kamoer KPAS-100. This image illustrates the color-coded wires and their corresponding A+/A-/B+/B- connections for the stepper motor.
Typical Wiring (Refer to your specific stepper driver documentation):
- A+: Black Line
- A-: Red Line
- B+: Blue Line
- B-: Green Line
Note: Wire colors may vary. Always cross-reference with the motor's label or manufacturer's specifications. A customer reported their motor having Green, Red, Orange, Yellow wires, which they successfully mapped to A1: Green, A2: Red, B1: Orange, B2: Yellow. This highlights the importance of verifying the specific wiring for your unit.
6. Funcionament
6.1 Encès
Once the pump is securely mounted and wired to a compatible stepper motor control board, apply DC 24V power to the control board.
6.2 Ajust de velocitat
The flow rate and speed of the peristaltic pump are controlled via the connected stepper motor control board. Refer to your control board's manual for instructions on adjusting motor speed and direction.
6.3 Preparació inicial
For initial use or after tube replacement, it may be necessary to prime the pump to ensure consistent flow. Run the pump at a moderate speed until fluid flows smoothly through the system without air bubbles.
7. Manteniment
7.1 Substitució del tub
The Pharmed BPT tube has a service life of over 1000 hours. Replace the tube when signs of wear, cracking, or reduced performance are observed. Always use genuine Kamoer replacement tubing to ensure compatibility and optimal performance.
- Desconnecteu l'alimentació de la bomba.
- Carefully open the pump head mechanism.
- Traieu el tub antic.
- Install the new tubing, ensuring it is properly seated within the pump head.
- Close the pump head mechanism securely.
- Reconnect power and prime the pump.
7.2 Neteja
Regularly inspect the pump head and exterior for any spills or debris. Clean with a damp cloth. Do not immerse the motor in liquid. If the pump is used with corrosive liquids, ensure the exterior is cleaned promptly after any spills.
7.3 Lubricació
Periodically check the rollers within the pump head. If the pump does not roll smoothly, especially at low speeds, a small amount of appropriate lubricant (e.g., silicone grease) may be applied to the rollers or the interior of the pump head, ensuring it does not contaminate the fluid path.
8. Solució De Problemes
| Problema | Causa possible | Solució |
|---|---|---|
| La bomba no funciona | No power to control board; Incorrect wiring; Faulty control board or motor. | Check power supply; Verify wiring connections (refer to Section 5.3); Test control board and motor if possible. |
| Inconsistent or no flow | Air in tubing; Kinked or obstructed tubing; Worn pump tube; Incorrect speed setting. | Prime the pump; Check tubing for kinks or blockages; Replace pump tube; Adjust speed on control board. |
| La bomba fa un soroll inusual | Dry rollers; Debris in pump head; Motor issue. | Lubricate rollers (Section 7.3); Inspect and clean pump head; Contact support if motor noise persists. |
| Pump head cracking | Material incompatibility with fluid; Excessive pressure; Manufacturing defect. | Ensure fluid is compatible with pump head materials; Verify system pressure is within limits; Contact manufacturer for replacement. |
9. Aplicacions
The Kamoer KPAS-100 peristaltic pump is suitable for a wide range of applications requiring precise and controlled fluid transfer, including:
- Filling and packaging systems
- Laboratory and experimental research
- Seguiment ambiental
- Inkjet and printing systems
- Aquarium dosing
- Smart home fluid management
- Aviation operations (specific fluid transfer tasks)

Figura 4: Examples of Kamoer pump applications. This collage shows various settings where the pump can be utilized, such as experimental research, environmental monitoring, inkjet printing, aquariums, smart homes, and aviation.
10. Garantia i Suport
For warranty information, technical support, or replacement parts, please contact Kamoer Fluid Tech (Shanghai) Co., Ltd. or your authorized distributor. Ensure you have your model number (KPAS-100) and purchase details available when contacting support.
Fabricant: Kamoer Fluid Tech (Shanghai) Co., Ltd.
Contacte: For inquiries, please refer to the contact information provided with your product packaging or visit the official Kamoer weblloc.