Walfront Walfrontm160hrd9ey6020-12

STVP-936 LCD Adjustable Voltage Manual d'usuari de Protector

Comprehensive guide for the installation, operation, and maintenance of your Walfront STVP-936 Three-Phase LCD Multifunctional Self-Resetting Voltage Protector.

1. Producte acabatview

The Walfront STVP-936 is a sophisticated three-phase four-wire automatic reset over-voltage, baix voltage, and multi-function protector. Designed for power systems and electrical equipment, it provides comprehensive protection against various electrical anomalies, ensuring the safety and longevity of connected devices. It integrates over-voltage, baix voltage, over-current, three-phase voltage unbalance, phase sequence (phase dislocation), and phase-break protection into a single unit.

Walfront STVP-936 LCD Adjustable VoltagProtector frontal electrònic view

Figura 1: Frontal view of the STVP-936 LCD Adjustable Voltage Protector, showing the LCD display and control buttons.

Característiques principals:

  • Restabliment automàtic: Automatically restores power when voltage returns to normal after an anomaly.
  • Multifunctional Protection: Combines over-voltage, baix voltage, over-current, three-phase unbalance, phase sequence, and phase-break protection.
  • Pantalla LCD: Clear display for real-time voltage and current readings, and easy parameter adjustment.
  • Fault Inquiry: Allows users to check fault history.
  • Paràmetres ajustables: Customizable protection values and recovery times.

2. Configuració i instal·lació

2.1 Precaucions de seguretat

  • Assegureu-vos que tot l'alimentació estigui desconnectada abans de la instal·lació o el manteniment.
  • La instal·lació l'ha de fer un electricista qualificat.
  • Verify correct wiring according to the provided diagrams and local electrical codes.
  • No feu funcionar el dispositiu si sembla que està danyat.

2.2 Instruccions de muntatge

The STVP-936 is designed for rail vertical installation. Ensure adequate space for ventilation and wiring connections. Mount the device securely on a standard DIN rail within an electrical enclosure.

Dimensions of the STVP-936 Voltage Protector

Figure 2: Dimensions of the STVP-936, indicating its compact size for rail mounting.

2.3 Esquema de cablejat

The device is suitable for three-phase four-wire power systems (230V/400VAC 50/60Hz). Connect the incoming power lines (L1, L2, L3, N) to the "IN" terminals and the outgoing load lines to the "OUT" terminals. Refer to the diagram printed on the device for specific terminal identification (N, L1, L2, L3).

lateral view of STVP-936 showing input and output terminals

Figura 3: lateral view illustrating the input (IN) and output (OUT) terminals for wiring connections.

3. Guia de funcionament

3.1 Pantalla LCD

The LCD screen provides real-time monitoring of voltage and current. It also displays fault codes and allows for parameter configuration.

Close-up of STVP-936 LCD display and control buttons

Figura 4: Detallada view of the LCD display and the 'SET', 'Up', and 'Down' buttons for navigation and adjustment.

3.2 Configuració de paràmetres

Utilitza el SET button to enter the parameter setting mode. Use the Up () i Avall () buttons to adjust values. Press SET again to confirm and move to the next parameter. The device will automatically save settings after a short period of inactivity in setting mode.

Paràmetres ajustables:

  • Valoració actual: 1-63A adjustable (default 63A).
  • Overvoltage Protection Value (Uvo): 221V-300V-OFF (default 280V).
  • OvervoltagValor de recuperació electrònica: 220V-299V (default 250V).
  • Overvoltage Protection Action Time: 0.1-10 seconds (default 0.2 seconds).
  • Undervoltage Protection Value (Uve): 219V-150V-OFF (default 160V).
  • UndervoltagValor de recuperació electrònica: 220V-151V (default 180V).
  • Undervoltage Protection Action Time: 0.1-10 seconds (default 0.2 seconds).
  • Overcurrent Protection Action Time: 1-512 seconds (default 5 seconds).
  • Trifàsic Voltage Unbalance Protection Value: 5%-90%-OFF (default 25%).
  • Fase Voltage Unbalance Protection Action Time: 0.1-10 seconds (default 2.0 seconds).
  • Power-On Delay Time: 2-255 seconds (default 2 seconds).
  • Failure Recovery Delay Time: 2-512 seconds (default 60 seconds).

3.3 Restauració de la configuració de fàbrica

The device has a function to restore factory default settings. Refer to the specific instructions in the full product manual or contact support for the exact procedure.

4. Manteniment

The STVP-936 is designed for minimal maintenance. However, periodic checks are recommended to ensure optimal performance and safety:

  • Neteja: Keep the device clean and free from dust. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
  • Comprovació de la connexió: Inspeccioneu periòdicament les connexions del cablejat per assegurar-vos que estiguin ben fixades i que no presentin corrosió.
  • Condicions ambientals: Assegureu-vos que l'entorn de funcionament es mantingui dins dels rangs de temperatura i humitat especificats.

5. Solució De Problemes

If the device is not functioning as expected, consider the following common issues:

  • Sense alimentació/Pantalla apagada: Check incoming power supply and wiring connections. Ensure the device is correctly installed.
  • Sortides freqüents: Review the set protection parameters (overvoltage, minvartage, overcurrent) to ensure they are appropriate for your electrical system. Check for actual power fluctuations or overloads.
  • Lectures incorrectes: Verify wiring. If readings are consistently inaccurate, the device may require professional inspection.
  • Device Not Resetting: Check the failure recovery delay time setting. Ensure the fault condition has cleared.

The device also features a fault inquiry function. Consult the full product manual for details on how to access and interpret fault codes.

6. Especificacions tècniques

Paràmetre Valor
Voltage (Three-Phase Four-Wire) 230V/400VAC 50/60Hz
Current Rating (Adjustable) 1-63A (63A per defecte)
Overvoltage Protection Value Range 221V-300V-OFF (default 280V)
Overvoltage Recovery Value Range 220V-299V (default 250V)
Overvoltage Protection Action Time 0.1-10 seconds (default 0.2 seconds)
Undervoltage Protection Value Range 219V-150V-OFF (default 160V)
Undervoltage Recovery Value Range 220V-151V (default 180V)
Undervoltage Protection Action Time 0.1-10 seconds (default 0.2 seconds)
Overcurrent Protection Action Time 1-512 seconds (default 5 seconds)
Trifàsic Voltage Unbalance Protection Value 5%-90%-OFF (default 25%)
Fase Voltage Unbalance Protection Action Time 0.1-10 seconds (default 2.0 seconds)
Power-On Delay Time 2-255 seconds (default 2 seconds)
Failure Recovery Delay Time 2-512 seconds (default 60 seconds)
Consum d'energia ≤ 3VA
Mode de visualització LCD
Mètode d'instal·lació Rail vertical installation
Temperatura de l'entorn de treball -20 ℃ ~ 50 ℃
Ambient de treball Humitat <85%
Altitud No més de 2000 metres
Dimensions (aprox.) 70 x 95mm (2.8 x 3.7in), 65mm (2.6in), 43mm (1.7in), 45mm (1.8in), 35mm (1.4in)
Pes de l'article 13.5 unces

7. Garantia i Suport

7.1 Informació de la garantia

Please refer to the manufacturer's official warranty policy for details regarding coverage, terms, and conditions. Typically, electronic devices come with a limited warranty against manufacturing defects.

7.2 Atenció al client

For technical assistance, troubleshooting, or warranty claims, please contact Walfront customer support. You can find more information and contact details by visiting the official Walfront store page:

Visita la botiga Walfront a Amazon

Documents relacionats - Walfrontm160hrd9ey6020-12

Preview TA881A Non-Contact AC Voltage Tester Pen - Product Manual
Comprehensive product manual for the TA881A Non-Contact AC Voltage Tester Pen, detailing its features, specifications, operation, precautions, and maintenance for electrical testing tasks.
Preview Mesurador de relació de voltes de transformador MECO TTR8100: proves elèctriques precises
Exploreu el MECO TTR8100, un instrument portàtil per a la mesura precisa de la relació de voltes i el volum d'excitació de transformadors/VT/CT monofàsics i trifàsics.tagMesures de corrent, angle de fase i desviació. Compta amb connectivitat Bluetooth i registre de dades complet.
Preview ORTOVOX Clasp Spine Protector - Motorcycle Back Protection
Detailed information on the ORTOVOX Clasp Spine Protector, a durable and multi-impact back protector designed for motorcycling, offering EN1621-2:2014 certified protection. Learn about its features, usage, safety, and care.
Preview ABB SACE Emax 2 de baix volumtagCatàleg tècnic d'interruptors automàtics en aire
Catàleg tècnic complet que detalla la sèrie SACE Emax 2 d'ABB de baix volumtagInterruptors automàtics en aire, que cobreixen característiques, especificacions, protecció, connectivitat i accessoris per a sistemes de distribució elèctrica avançats.
Preview ANENG VC1010 Non-Contact Voltage Tester - Operation Instructions and Technical Specifications
Detailed operation instructions and technical specifications for the ANENG VC1010 non-contact voltage tester, including power on/off, torch function, AC voltage detection, auto power off, battery replacement, and detailed technical parameters.
Preview Phoenix Phase Converters GP50NL 50 HP Rotary Phase Converter Manual
Installation and operation guide for the Phoenix Phase Converters GP50NL 50 HP Rotary Phase Converter. Covers safety, power requirements, wiring, dimensions, and component details for industrial use.