Elitech ECB-5080S

Manual d'usuari del quadre de control elèctric Elitech ECB-5080S del panell de control de temperatura

Model: ECB-5080S

1. Producte acabatview

The Elitech ECB-5080S is an advanced electrical control box designed for precise temperature management in various applications. It integrates an MTC-6000N controller to manage cooling, defrosting, and fan operations. This unit is suitable for systems requiring 3-phase 380V power and up to 15Hp capacity, offering comprehensive protection features for reliable operation.

Elitech ECB-5080S Electrical Control Box front view

Imatge 1: Frontal view of the Elitech ECB-5080S Electrical Control Box, showing the control panel with two digital displays, indicator lights for Power, Comp, Defr, Fan, and Fault, and an ON/OFF switch.

2. Característiques clau

  • Monitorització remota: Parameters can be viewed or set remotely via website and mobile application. Data and graph reports are available in real-time.
  • Pantalla dual: Shows temperature on both integrated temperature controllers. Multiple indicator lights display the operational status of each connected device.
  • Multi-Alarms: Provides alerts for temperature over-limit, over-range conditions, or sensor malfunctions.
  • Protecció integral: Includes high-pressure, low-pressure, module, overload, phase sequence, phase loss, three-phase unbalance, and inverse time protection.
  • Funcionalitat: Offers refrigeration, defrosting, and fan three-way output. Equipped with two storage temperature sensors and one defrosting temperature sensor.

3. Configuració i instal·lació

Proper installation is crucial for the safe and efficient operation of the ECB-5080S control box. It is recommended that installation be performed by a qualified electrician.

  1. Muntatge: Securely mount the control box in a suitable location, ensuring adequate ventilation and protection from environmental elements.
  2. Connexió d'alimentació: Connect the 3-phase 380V power supply to the designated terminals. Verify correct phase sequence and voltage.
  3. Connexions de càrrega: Connect the refrigeration unit, defrosting heaters, and fan motors to their respective output terminals as per the wiring diagram (refer to the detailed wiring diagram provided with the product packaging).
  4. Instal·lació del sensor: Install the two storage temperature sensors and one defrosting temperature sensor in their appropriate locations within the controlled environment. Ensure sensors are correctly positioned for accurate readings.
  5. Posada a terra: Ensure the control box is properly grounded to prevent electrical hazards.
Elitech ECB-5080S Electrical Control Box angled view

Imatge 2: Anglesa view of the Elitech ECB-5080S Electrical Control Box, highlighting the side ventilation and overall robust construction.

4. Instruccions de funcionament

The ECB-5080S utilizes an MTC-6000N controller for its primary functions. Familiarize yourself with the controller's interface for optimal use.

  • Encès/apagat: Use the main ON/OFF switch on the front panel to power the unit.
  • Visualització de la temperatura: The dual digital displays show current temperatures. Refer to the MTC-6000N controller manual for specific display interpretations.
  • Paràmetres de configuració: Access the controller's menu to set desired temperature ranges, defrost cycles, fan operation modes, and alarm thresholds. Consult the MTC-6000N controller's dedicated manual for detailed parameter setting procedures.
  • Llums indicadores:
    • POTÈNCIA: Indica que la unitat està rebent alimentació.
    • COMP: Indicates the compressor (cooling) is active.
    • DEFR: Indicates the defrost cycle is active.
    • VENTILADOR: Indicates the fan is operating.
    • FALLA: Illuminates when an error or alarm condition is detected. Refer to troubleshooting for details.
  • Accés remot: Utilize the Elitech website or mobile application for remote monitoring and parameter adjustments. Ensure the unit is connected to a network as per its network configuration guide.
Elitech ECB-5080S Electrical Control Box with ON/OFF switch

Imatge 3: Primer pla view of the Elitech ECB-5080S control panel, emphasizing the ON/OFF switch and the two integrated temperature controllers.

5. Manteniment

Regular maintenance ensures the longevity and optimal performance of your ECB-5080S control box.

  • Neteja: Periodically clean the exterior of the control box with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Ventilació: Ensure that ventilation openings are clear of dust and obstructions to prevent overheating.
  • Connexions: Annually inspect all electrical connections for tightness and signs of corrosion. Tighten any loose connections.
  • Comprovació del sensor: Verify that temperature sensors are clean and securely mounted. Check sensor cables for damage.
  • Actualitzacions de programari: Check the Elitech website or app for any available firmware updates for the MTC-6000N controller to ensure optimal functionality and security.

6. Solució De Problemes

This section provides solutions to common issues. For complex problems, contact Elitech technical support.

ProblemaCausa possibleSolució
La unitat no s'encén.No power supply; main switch off; faulty wiring.Check power source; ensure main switch is ON; inspect wiring connections.
La visualització de la temperatura no és precisa.Faulty sensor; sensor incorrectly placed; wiring issue.Check sensor connections; verify sensor placement; replace faulty sensor if necessary.
FAULT indicator is lit.Over-limit temperature; sensor error; protection activated (e.g., phase loss).Check alarm messages on controller; inspect sensors; verify power supply and phase integrity.
Cooling/Defrost/Fan not operating.Incorrect parameter settings; faulty output relay; motor/component failure.Verify controller settings; check indicator lights; inspect connected components.

7. Especificacions

MarcaElitech
Número de modelECB-5080S
Voltage380 Volts (3 Phase)
Potència màxima15 CV
Tipus de controladorMTC-6000N
FuncionsRefrigeration, Defrosting, Fan Control
Característiques de proteccióHigh/Low Pressure, Module, Overload, Phase Sequence/Loss, Three-phase Unbalance, Inverse Time
ASINB097MXGKFP
UPC781454242337

Documents relacionats - ECB-5080S

Preview Solucions de control de temperatura de processos i refrigeració industrial d'Elitech
Elitech ofereix una gamma completa de solucions de control de temperatura per a aplicacions de refrigeració industrial i processos. Aquest document detalla diversos termostats, panells de control elèctric i protectors multiusos, destacant les seves característiques, especificacions tècniques i escenaris d'aplicació.
Preview Manual d'usuari del controlador de temperatura Elitech MTC-2120S
Manual d'usuari de l'Elitech MTC-2120S, un controlador de temperatura versàtil d'un sol sensor amb funcions d'alarma de refrigeració, descongelació i sobretemperatura. Inclou paràmetres tècnics, instruccions de funcionament, diagrames de cablejat i resolució de problemes.
Preview MTC-5080 Operation Instructions and Technical Specifications
Comprehensive guide to the MTC-5080 digital temperature controller, detailing its functions, specifications, operation, and safety guidelines for cold storage temperature control.
Preview Manual d'usuari del monitor de temperatura Elitech RCW-600WIFI IoT
Manual d'usuari de l'Elitech RCW-600WIFI, un monitor de temperatura IoT de dos canals amb connectivitat WiFi per a dades remotes viewInstrucció, seguiment i gestió en les indústries alimentària, de càtering, logística i APPCC.
Preview Elitech Product Selection Guide: Refrigeration and Industrial Control Solutions
A comprehensive product selection guide from Elitech, featuring a wide range of refrigeration and industrial control equipment, including temperature controllers, data loggers, leak detectors, pressure transducers, and more. This guide provides detailed specifications, applications, and technical parameters for various Elitech products.
Preview Manual d'usuari del controlador de temperatura Elitech STC-9200A
User manual for the Elitech STC-9200A, a universal-type temperature controller. This document provides details on product overview, operation, specifications, technical parameters, indicator status, button functions, parameter lists, safety rules, and control outputs.