Introducció
This manual provides detailed instructions for the installation, operation, and maintenance of your Jebao MCP-120 Smart Cross Flow Pump. Please read this manual thoroughly before use to ensure proper function and longevity of the product. This pump is designed to create optimal water movement in both marine and freshwater aquarium environments.
Producte acabatview
The Jebao MCP-120 Smart Cross Flow Pump utilizes advanced crossflow technology to generate comprehensive water movement within your aquarium, eliminating dead spots and mimicking natural wave patterns. Key features include:
- Control intel·ligent: Equipped with a manual LCD display controller and WiFi connectivity for both iOS and Android devices.
- Funcionament silenciós: Incorporates SINE wave technology for ultra-quiet and stable performance.
- Flux d'aigua eficient: Features a cross-wave double impeller structure designed to prevent dead spots in water circulation.
- Ús versàtil: Constructed without exposed copper elements, making it suitable for both marine and freshwater aquariums.
- Característiques de seguretat: Includes IC electronic detection, dry/locked rotor protection, and automatic power-off in low water conditions.
Contingut del paquet
Desembaleu amb cura tots els components i verifiqueu que heu rebut els articles següents:

Image: All components of the Jebao MCP-120 Smart Cross Flow Pump laid out. This includes the main pump unit, the LCD display controller, the power adapter, the magnetic mounting base, and the user manual.
- Jebao MCP-120 Cross Flow Pump Unit
- LCD Display Controller
- Power Adapter (100V-240V, DC 24V 45W)
- Base de muntatge magnètica
- Manual d'usuari (aquest document)
Instruccions de seguretat
Si us plau, observeu les següents precaucions de seguretat per evitar lesions o danys al producte:
- Desconnecteu sempre l'alimentació abans de realitzar qualsevol manteniment o instal·lació.
- Ensure the pump is fully submerged in water during operation to prevent dry running.
- No feu funcionar la bomba si el cable d'alimentació o l'endoll estan danyats.
- Keep the power adapter and controller away from water splashes.
- This product is designed for indoor aquarium use only.
- Do not attempt to disassemble or repair the pump or controller yourself. Contact qualified personnel for service.
- Ensure the magnetic base is securely attached to the aquarium glass, avoiding any obstructions.
Guia de configuració
- Col·locació de la bomba: Select a suitable location inside your aquarium for the pump. The cross-flow design works best when placed horizontally along the back or side wall, allowing water to flow across the tank.
- Muntatge magnètic: Attach the pump unit to the inner side of the aquarium glass. Position the external magnet on the corresponding outer side of the glass, aligning it with the internal magnet. Ensure a firm and secure attachment.
- Connexió del controlador: Connect the pump's cable to the designated port on the LCD display controller.
- Connexió d'alimentació: Connect the power adapter to the controller, then plug the adapter into a standard electrical outlet.
- Inici inicial: Once powered, the LCD controller will illuminate. The pump will begin operating in its default mode.

Image: The Jebao MCP-120 pump unit shown with its magnetic mounting base. The pump is designed to be mounted horizontally on the aquarium glass using this magnetic system.

Imatge: Una imatge detallada view of the Jebao MCP-120 pump unit. This image emphasizes the dual impeller design, which is central to its cross-flow water movement capability.
Instruccions de funcionament
The Jebao MCP-120 pump can be controlled via its LCD display controller or through a mobile application using WiFi.
LCD Display Controller
The LCD display controller allows for direct adjustment of pump modes and flow intensity. Refer to the controller's interface for specific button functions (e.g., Mode, Speed, Feed, Lock).
- Selecció del mode: Cycle through various flow modes (e.g., constant flow, wave mode, random flow) using the 'Mode' button.
- Ajust de cabal: Adjust the water flow rate using the 'Speed' or '+' / '-' buttons.
- Mode d'alimentació: Activate a temporary pause in pump operation for feeding, typically for 10 minutes, using the 'Feed' button.
- Funció de bloqueig: Use the 'Lock' button to prevent accidental changes to settings.
WiFi Connectivity and App Control
The pump supports control via a mobile application (iOS and Android). For successful WiFi connection, please note the following critical steps:
- Dedicated 2.4GHz Network: Your WiFi router must have a dedicated 2.4GHz network with a unique name, separate from any 5GHz network. The pump does not support 5GHz WiFi.
- Mobile Device Connection: Ensure your mobile device is connected to this dedicated 2.4GHz network before attempting to pair the pump.
- Instal·lació de l'aplicació: Download the official Jebao app from your device's app store.
- Afegir un dispositiu: In the app, select 'Add a Wi-Fi device' and then 'Wave Pump'.
- Detalls de la xarxa: Confirm your 2.4GHz network name is displayed and enter its password.
- AP Network Mode: On the next screen in the app, switch from 'Smart Network' to the 'AP Network' tab.
- Controller AP Mode: Turn on the pump controller. Long-press the network button on the controller until the WiFi logo flashes along with the 'AP' indicator.
- Connect Phone to Pump AP: Connect your phone's WiFi directly to the new network named 'Jebao_WiFi-XXX' (where XXX is a unique identifier). The default password is '123456789'.
- Connexió completa: Return to the Jebao app and click 'Next'. The app should now successfully connect to the controller.
- Restore Phone WiFi: After successful pairing, your phone's WiFi should automatically reconnect to your home 2.4GHz network, and the pump controller will also be connected to your home network.
Once connected, the app provides advanced scheduling and control options for your pump.
Manteniment
Regular maintenance ensures optimal performance and extends the lifespan of your Jebao MCP-120 pump.
- Cleaning the Impellers: Periodically remove the pump from the aquarium and carefully disassemble the impeller covers. Clean the impellers and their housing using a soft brush and fresh water to remove any algae, debris, or calcium buildup.
- Base magnètica: Inspect the magnetic base for any signs of wear or corrosion. Clean both the internal and external magnets to ensure a strong grip on the aquarium glass.
- Power Cord and Connections: Check the power cord and all connections for any damage or fraying. Replace if necessary.
- Controlador: Keep the LCD controller clean and dry. Avoid exposing it to direct water splashes.

Image: A top-down perspective of the Jebao MCP-120 pump, revealing the dual impellers and the protective grates. Regular cleaning of these components is essential for maintaining pump efficiency.
Always disconnect the pump from power before performing any cleaning or maintenance.
Resolució de problemes
If you encounter issues with your Jebao MCP-120 pump, refer to the following common solutions:
| Problema | Causa possible | Solució |
|---|---|---|
| La bomba no s'encén. | No power, loose connection, dry running protection activated. | Check power outlet and connections. Ensure pump is fully submerged. If dry running protection activated, disconnect power, wait a few minutes, then reconnect. |
| Weak or inconsistent flow. | Clogged impellers, debris in pump, low power setting. | Clean impellers and pump housing. Increase flow setting on controller or app. |
| Pump making unusual noise. | Debris in impeller, worn impeller, improper installation. | Disconnect power and inspect impellers for debris. Ensure pump is securely mounted and not vibrating against the glass. |
| No es pot connectar al Wi-Fi / aplicació. | Incorrect WiFi band (5GHz), incorrect password, improper pairing steps. | Ensure your router has a dedicated 2.4GHz network and your phone is connected to it. Follow the WiFi setup steps precisely, especially the AP Network mode. Verify WiFi password. |
| Controller display is blank or unresponsive. | Power issue, controller malfunction. | Check power connections. Try disconnecting and reconnecting the controller. If issue persists, contact support. |
Especificacions
| Característica | Detall |
|---|---|
| Model | MCP-120 |
| Dimensions (L x A x A) | 11.5" x 2.5" x 1.5" |
| Entrada Voltage | CA 100V-240V, 50 / 60Hz |
| Vol. De sortidatage | DC 24V |
| Wattage | 45W |
| Assumed Flow Rate | 4300 a 4600 GPH |
| Classificació de protecció | IPX8 (Must run into water) |
| Temperatura màxima de l'aigua | 35 °C |
| Endoll | Endoll dels EUA de 3 puntes |
| Compatibilitat | Marine and Fresh Water |
Garantia i Suport
For warranty information and technical support, please refer to the documentation provided at the point of purchase or contact your retailer. Keep your purchase receipt as proof of purchase for any warranty claims.
For further assistance or inquiries, please visit the official Jebao weblloc o poseu-vos en contacte amb el seu departament d'atenció al client.