The Walfront D52-2066 is a single-phase energy meter designed for monitoring electricity usage in both household and industrial settings. It features a full viewing angle colorful LCD screen that simultaneously displays six key electrical parameters: AC voltage, AC current, active power, power factor, frequency, and electric energy (kWh).

This compact and lightweight device is suitable for DIN rail installation, making it a practical solution for various applications including chemical industry, power plants, automation equipment, and electromechanical systems. Its design allows for easy monitoring of total electricity consumption.

Walfront D52-2066 Single Phase Energy Meter

The Walfront D52-2066 Single Phase Energy Meter, showcasing its colorful LCD display and compact design.

Característiques principals:

  • Pantalla LCD: Complet viewing angle colorful LCD screen for clear readability.
  • 6 Parameters Display: Simultaneously displays AC voltage, AC current, active power, power factor, frequency, and electric energy.
  • Monitorització energètica: Allows for continuous monitoring of household or industrial electricity consumption.
  • Aplicació àmplia: Suitable for chemical industry, power plants, automation equipment, DOS systems, and electromechanical equipment.
  • Disseny compacte: Small size and lightweight for easy installation and portability.

Especificacions

ParàmetreValor
Tipus d'elementWatt‑Hour Meter
ModelD52-2066
MaterialABS
Precisió de la mesura1%±2 Words
Vol. ACtage Interval de mesuraAC 40.0-300.0V
AC Current Measuring RangeAC 0-100.0A
Resolució de pantalla actual0.01A
Freqüència de potència45.0Hz-65.0Hz
Factor de potència0.00-1.00PF
Velocitat de mesuraUnes 2 vegades per segon
Mètode d'instal·lacióTipus de ferrocarril
Dimensions del paquet3.39 x 2.91 x 2.32 polzades
Pes de l'article4.94 unces

Note: The measuring voltage range of this instrument is 40-300V and is only suitable for pure AC 45-65Hz mains power.

Dimensions of D52-2066 Energy Meter

Visual representation of the D52-2066 meter's dimensions: approximately 80mm (3.15in) height, 54mm (2.13in) width, and 48mm (1.89in) depth.

Configuració i instal·lació

The D52-2066 energy meter is designed for easy installation on a DIN rail. Follow the instructions below for proper wiring.

Instruccions de cablejat:

  1. Connect Measured Voltage: Connecteu l'AC voltage to be measured to terminals 1 and 2 located on the bottom left of the meter.
  2. Built-in Transformer Wiring (Figure 2):

    For using the built-in transformer, pass the wire of the measurement circuit through the circular hole on the top of the meter and out from the bottom. The penetration direction can be chosen arbitrarily by the user. The 3 and 4 terminals are not used in this configuration.

    Wiring diagram for built-in transformer

    Figura 2: Wiring diagram for the built-in transformer. This diagram shows how to pass the load wire through the meter's internal current transformer. The AC measurement input connects to terminals 1 and 2. The load electrical appliances are connected in series with the wire passing through the meter's sensing hole.

  3. External Transformer Wiring (Figure 1):

    If using an external current transformer (CT), connect the two wires from the secondary end of the external CT to terminals 3 and 4 on the upper left of the meter. Then, pass the wire of the measurement circuit through the external CT. The load wire passing through the transformer is not polarized; simply pass it through one at a time.

    Wiring diagram for external transformer

    Figura 1: Wiring diagram for an attached (external) transformer. This diagram illustrates connecting an external current transformer (CT) to terminals 3 and 4, with the load wire passing through the external CT. AC measurement input connects to terminals 1 and 2.

After wiring, the meter will display measurement parameters once power is supplied.

Example wiring setup with multiple circuit breakers

Un example of a typical wiring setup showing the energy meter connected within a circuit with multiple circuit breakers. This setup allows for clear monitoring of electricity consumption for various household appliances.

Instruccions de funcionament

The D52-2066 meter provides real-time display of various electrical parameters on its colorful LCD screen.

Paràmetres de visualització:

The meter simultaneously displays the following six parameters:

  • Vol. ACtage (V)
  • Corrent alterna (A)
  • Potència activa (W)
  • Factor de potència (PF)
  • Freqüència (Hz)
  • Electric Energy (kWh)
D52-2066 LCD display showing 6 parameters

The meter's LCD display showing the six measured parameters: AC Voltage, AC Current, Active Power, Power Factor, Frequency, and Electric Energy (kWh). Each parameter is clearly labeled and displayed with its corresponding unit.

Resetting Energy Measurement (kWh):

To reset the accumulated energy measurement (kWh) to zero, follow these steps:

  1. Locate the "RESET" button on the right side of the instrument panel.
  2. Press and hold the "RESET" button for approximately 5 seconds.
  3. Continue holding until the energy display (kWh) shows "0".
  4. Release the button. The electrical energy measurement will now start from zero.
Close-up of D52-2066 showing reset button

Un primer pla view of the D52-2066 meter highlighting the "RESET" button and the clear LCD screen. This button is used to clear the accumulated energy (kWh) reading.

Manteniment

To ensure the longevity and accurate performance of your D52-2066 energy meter, follow these general maintenance guidelines:

  • Neteja: Use a soft, dry cloth to clean the meter's exterior. Do not use abrasive cleaners or solvents, as they may damage the display or casing.
  • Medi ambient: Install the meter in a dry, well-ventilated area, away from direct sunlight, excessive heat, humidity, and corrosive gases.
  • Manipulació: Handle the meter with care to avoid physical damage. Ensure all connections are secure and free from dust or debris.
  • Inspecció: Periodically inspect the wiring connections for any signs of wear, corrosion, or loosening.
D52-2066 meter highlighting insulation materials

The D52-2066 meter is constructed with insulated ABS shell materials, providing good impact resistance and high/low temperature resistance. This contributes to its accuracy, durability, and security in various operating environments.

Resolució de problemes

If you encounter issues with your D52-2066 energy meter, refer to the following common troubleshooting tips:

ProblemaCausa possibleSolució
Meter not powering on/displayingNo power supply; incorrect wiring; voltage fora de l'abast.
  • Verify power supply to terminals 1 and 2.
  • Check all wiring connections according to the setup diagrams.
  • Assegureu-vos que AC voltage es troba dins del rang 40V-300V.
Lectures inexactesIncorrect CT connection (for external CT); wire not properly passed through built-in CT; interference.
  • For external CT, ensure secondary wires are connected to terminals 3 and 4 correctly.
  • For built-in CT, ensure the load wire passes completely through the sensing hole.
  • Minimize electromagnetic interference from other devices.
kWh reading not resettingEl botó no es manté prou temps.Press and hold the "RESET" button for a full 5 seconds until the display clears to zero.
Pantalla parpellejant o inestableUnstable power supply; environmental factors.
  • Ensure a stable AC power source.
  • Check for extreme temperatures or humidity.

Si el problema persisteix després d'intentar aquestes solucions, poseu-vos en contacte amb el servei d'atenció al client de Walfront per obtenir més ajuda.

Garantia i Suport

Walfront products are manufactured to high-quality standards. For information regarding warranty coverage, please refer to the documentation included with your purchase or visit the official Walfront weblloc.

For technical support, troubleshooting assistance beyond this manual, or inquiries about replacement parts, please contact Walfront customer service. Keep your product model number (D52-2066) and purchase details ready when contacting support.

A detailed manual is included in the product package for comprehensive guidance.

Documents relacionats - D52-2066

Preview D52-2066 DIN-rail Multi-function Digital AC Meter User Guide
User guide and technical specifications for the D52-2066 DIN-rail multi-function digital AC meter. Covers voltage, current, power, energy, frequency, and power factor measurements, wiring, and specifications.
Preview D52-2066 Rail Type Digital Multifunction Electricity Meter Specifications and Features
Detailed specifications and features of the D52-2066 rail type digital multifunction electricity meter, including AC voltage, current, power, frequency, and power factor measurement capabilities.
Preview EARU D52-2066 Series Single Phase Multi-functional Energy Meter | Technical Specifications
Detailed technical specifications and wiring instructions for the EARU D52-2066 Series DIN-rail single-phase multi-functional energy meter, measuring AC voltage, current, active power, power factor, frequency, and electric energy.
Preview HADEX R082A Multifunction DIN Rail Meter User Manual
User manual for the HADEX R082A multifunction digital meter (model D52-2066). This guide provides detailed information on technical parameters, connection methods, and usage for measuring voltage, current, power, frequency, and energy on a DIN rail. Includes maintenance, recycling, and warranty information.
Preview Guia de l'usuari del mesurador multifunció de carril DIN Ketotek D52-2047HD
Guia d'usuari del mesurador multifunció de carril DIN Ketotek D52-2047HD, que detalla les seves especificacions tècniques, mètodes d'aplicació i punts d'atenció per mesurar el volum de CAtage, corrent, potència activa, freqüència i energia elèctrica.
Preview D52-2047 DIN-Rail Multi-Function Digital Meter User Manual
This document provides details for the D52-2047 guide rail type digital display multifunction meter. It simultaneously displays AC voltage, AC current, power factor, active power, electrical energy, and the timing of electrical energy. Key specifications include accuracy, display modes, measurement ranges for voltage, current, active power, and electric energy, as well as speed, size, and installation type.