Fireangel CO-9X10

Manual d'usuari de l'alarma de monòxid de carboni FireAngel CO-9X10

La teva guia per a un ús segur i eficaç

Introducció

The FireAngel CO-9X10 is a certified carbon monoxide (CO) alarm designed to provide continuous monitoring for the presence of carbon monoxide gas. Featuring an advanced electrochemical sensor developed by FireAngel, this device ensures accurate detection of CO at low concentrations, offering maximum safety for your home or workplace. It comes with a built-in lithium battery designed for a 10-year lifespan, providing reliable protection without the need for battery replacement.

This manual provides essential information on the installation, operation, maintenance, and troubleshooting of your CO-9X10 alarm. Please read it thoroughly before installation and keep it for future reference.

FireAngel CO-9X10 Carbon Monoxide Alarm front view

Figura 1: Frontal view of the FireAngel CO-9X10 Carbon Monoxide Alarm. This image shows the main body of the alarm with the central test/reset button and the Power, Fault, and Alarm indicator lights.

Informació important de seguretat

Carbon monoxide (CO) is a colorless, odorless, and tasteless gas that can be fatal. This alarm is designed to detect carbon monoxide gas from any source of combustion. It is not designed to detect smoke, fire, or other gases. For optimal safety, ensure proper ventilation and regular maintenance of fuel-burning appliances.

Contingut del paquet

Si us plau, comproveu el contingut del paquet per assegurar-vos que hi hagi tots els elements:

Configuració i instal·lació

Selecció d'una ubicació

For optimal protection, install CO alarms in or near every room where fuel-burning appliances are located, and in sleeping areas. Consider placing an alarm on every level of your home. Avoid placing the alarm:

Muntatge de l'alarma

The CO-9X10 can be wall-mounted or placed on a flat surface. For wall mounting:

  1. Select a suitable location, ideally at eye level or higher, but not directly on the ceiling unless specified by local regulations.
  2. Use the mounting bracket as a template to mark the drill holes on the wall.
  3. Drill two holes and insert the provided wall plugs.
  4. Screw the mounting bracket firmly to the wall.
  5. Attach the CO alarm to the mounting bracket by aligning the alarm with the bracket and twisting it clockwise until it clicks into place.
FireAngel CO-9X10 Carbon Monoxide Alarm with indicators

Figura 2: Detall frontal view of the FireAngel CO-9X10 showing the Power, Fault, and Alarm LED indicators. This view is helpful for understanding the device's status at a glance.

FireAngel CO-9X10 Carbon Monoxide Alarm side view

Figura 3: lateral view of the FireAngel CO-9X10 Carbon Monoxide Alarm, illustrating its compact profile and potential mounting features. This perspective can be useful for understanding how the device sits against a wall or on a surface.

Activació inicial

The CO-9X10 features a sealed-in lithium battery. The alarm will activate automatically when it is correctly attached to its mounting bracket. Upon activation, the green Power LED will flash once every 45 seconds, indicating normal operation.

Instruccions de funcionament

Indicadors LED

Prova de l'alarma

It is crucial to test your CO alarm weekly to ensure it is functioning correctly.

  1. Press and hold the large "TEST/RESET" button on the front of the alarm.
  2. The alarm will sound a loud, distinctive pattern (typically 4 beeps, pause, 4 beeps) and the Red Alarm LED will flash.
  3. Release the button. The alarm should stop sounding, and the Red Alarm LED should stop flashing.
  4. If the alarm does not sound or the LEDs do not respond as described, refer to the Troubleshooting section.

Què fer si sona l'alarma

If your CO alarm sounds, it indicates the presence of carbon monoxide. Follow these steps immediately:

  1. Evacuate immediately: Move everyone, including pets, to fresh air outdoors or open doors/windows to ventilate the area.
  2. Do not re-enter the premises until the alarm has stopped and the area has been ventilated.
  3. Truqueu als serveis d'emergència: Contact your local emergency services (e.g., 999 in the UK) or a qualified gas technician to investigate the source of the CO.
  4. Identify and resolve the source: Do not use fuel-burning appliances until they have been checked by a professional.

Funció de silenci

The alarm may have a silence feature for nuisance alarms (e.g., from temporary high CO levels during appliance startup). Pressing the "TEST/RESET" button during an alarm may silence it for a short period. However, if the CO level remains high, the alarm will reactivate. Only use the silence feature if you are certain it is a nuisance alarm and not a genuine CO threat.

Manteniment

Neteja regular

Clean your CO alarm regularly to prevent dust and debris from affecting its performance. Use a soft, damp cloth to wipe the exterior. Do not use cleaning solvents or sprays directly on the alarm.

Battery Life and End-of-Life Signal

The FireAngel CO-9X10 is equipped with a sealed-in lithium battery designed to last for 10 years. When the alarm reaches the end of its operational life, it will emit a specific end-of-life signal (e.g., two short beeps every 45 seconds, accompanied by the Amber Fault LED flashing). When this occurs, the alarm needs to be replaced immediately.

Resolució de problemes

ProblemaCausa possibleSolució
Alarm sounds continuously (Red LED flashing)High level of Carbon Monoxide detected.Evacuar immediatament. Call emergency services. Do not re-enter until cleared by professionals.
Amber Fault LED flashing / Alarm chirping intermittentlyS'ha detectat una bateria baixa o un error.The battery is sealed and cannot be replaced. If the alarm is chirping due to low battery or fault, it has reached its end-of-life or is malfunctioning. Substituïu l'alarma immediatament.
Alarm does not sound when Test button is pressedAlarm malfunction or end-of-life.Ensure the alarm is properly mounted. If it still doesn't respond, the alarm is faulty or has reached its end-of-life. Substituïu l'alarma immediatament.
Green Power LED not flashingAlarm not activated or malfunction.Ensure the alarm is securely attached to its mounting bracket. If the issue persists, the alarm may be faulty. Substituïu l'alarma.

Especificacions

CaracterísticaDetall
Número de modelCO-9X10
Tipus de sensorElectroquímica
Font d'alimentacióSealed-in Lithium Battery (10-year life)
Volum de l'alarmaAudible
Dimensions del producte11.2 x 3.5 x 7.2 cm
Pes de l'article150 g
CertificacionsBSI EN50291-1:2010 and EN50291-2:2010 Certified
UPC816317003609

Garantia i Suport

FireAngel products are manufactured to the highest standards. For specific warranty information, please refer to the documentation included with your purchase or visit the official FireAngel website. If you experience any issues with your CO-9X10 alarm or require technical assistance, please contact FireAngel customer support. Do not attempt to repair the alarm yourself.

Informació de contacte: Please refer to the FireAngel website or your purchase documentation for the most up-to-date contact details for customer support in your region.

Documents relacionats - CO-9X10

Preview Manual d'usuari del detector de monòxid de carboni FireAngel CO-9X amb una vida útil de 7 anys
Manual d'usuari complet per a l'alarma de gas verinós de monòxid de carboni FireAngel CO-9X de 7 anys de vida útil. Apreneu sobre la instal·lació, el funcionament, el manteniment, la seguretat i la resolució de problemes.
Preview Manual d'usuari de l'alarma de monòxid de carboni FireAngel FA6813
Comprehensive user manual for the FireAngel FA6813 Carbon Monoxide Alarm, covering installation, operation, maintenance, troubleshooting, and safety information.
Preview Manual d'usuari de l'alarma combinada de fum i monòxid de carboni FireAngel SCB10
User manual for the FireAngel SCB10, a combination smoke and carbon monoxide alarm, providing comprehensive instructions on installation, operation, maintenance, and safety for residential use.
Preview Manual d'usuari de l'alarma de monòxid de carboni FireAngel FA6812/FA6813
Manual d'usuari dels detectors de monòxid de carboni (CO) FireAngel FA6812 i FA6813, que proporciona instruccions d'instal·lació, funcionament, seguretat i manteniment.
Preview FireAngel Multisensor Plus User Manual: Smoke, Heat, CO Detector
Comprehensive user manual for the FireAngel Multisensor Plus and Multisensor Plus Kitchen, detailing installation, operation, safety, troubleshooting, and technical specifications for smoke, heat, and carbon monoxide detection.
Preview FireAngel CO Alarms FA3313, FA3322, FA3328, FA3820 User Manual
Comprehensive user manual for FireAngel Carbon Monoxide alarms (models FA3313, FA3322, FA3328, FA3820), covering positioning, installation, CO alarm awareness, maintenance, status indicators, sleep easy feature, LCD screen indicators, and technical specifications. Includes warranty and disposal information.