Introducció
This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your Generico RURA Boiler Filling Tap. This tap is designed for use with various boiler systems, including Hermann, Radiant, and Unical models. Please read this manual thoroughly before proceeding with any installation or operation.
Informació de seguretat
Avís: Installation and maintenance should only be performed by qualified personnel. Always ensure the boiler system is depressurized and cooled before attempting any work. Turn off the main water supply to prevent leaks.
- Porteu sempre l'equip de protecció individual (EPI) adequat.
- Ensure all connections are secure to prevent water leaks.
- Do not overtighten connections, as this may damage the tap or piping.
- Mantenir els nens i les persones no autoritzades lluny de l'àrea de treball.
Producte acabatview
The RURA Boiler Filling Tap is a component designed to allow controlled filling of a boiler system with water. It typically consists of a brass body, a valve mechanism, and a control knob.

Figure 1: The Generico RURA Boiler Filling Tap, featuring a brass body and a black control knob. This component is crucial for regulating water flow into the boiler system.

Figure 2: A variant of the RURA Boiler Filling Tap, shown with a blue control knob. The design allows for manual operation to control water intake.
Configuració i instal·lació
Before installation, ensure you have the correct tools and that the boiler system is isolated from power and water supply.
- Depressurize the System: Turn off the boiler and allow it to cool. Close the main water inlet valve to the boiler. If necessary, drain some water from the system to reduce pressure.
- Locate the Connection Point: Identify the existing filling loop connection point on your boiler. This is typically where the old filling tap was or where a new one needs to be installed.
- Prepara l'aixeta: Inspect the new RURA filling tap for any damage. Ensure all seals (O-rings) are present and in good condition.
- Instal·leu l'aixeta: Carefully screw the RURA filling tap into the designated connection point. Use a suitable wrench to tighten it, but do not overtighten. Ensure the tap is oriented correctly for easy access to the control knob.
- Comproveu si hi ha fuites: Slowly open the main water inlet valve to the boiler. Inspect all connections around the newly installed tap for any signs of water leakage. Tighten slightly if minor leaks are observed.
- Repressurize the System: Once satisfied with the installation, proceed to the "Operating" section to fill and repressurize your boiler system.

Figura 3: superior view of the blue control knob, indicating the manual interface for operating the tap. This knob is used to open and close the water flow.
Instruccions de funcionament
The RURA Boiler Filling Tap is used to add water to your boiler system and maintain the correct operating pressure.
- Check Boiler Pressure: Refer to your boiler's pressure gauge. The recommended operating pressure is typically between 1.0 and 1.5 bar when the system is cold.
- Open the Filling Tap: Slowly turn the control knob of the RURA filling tap counter-clockwise to open the valve. You should hear water flowing into the system.
- Monitor de pressió: Observe the boiler pressure gauge as water enters the system.
- Close the Filling Tap: Once the desired pressure (e.g., 1.2 bar) is reached, slowly turn the control knob clockwise to close the valve completely. Do not overtighten.
- Verify Pressure: Recheck the pressure gauge to ensure the pressure is stable and within the recommended range.
- Important: Never leave the filling tap open unattended. Overfilling the system can lead to excessive pressure and potential damage.
Manteniment
The RURA Boiler Filling Tap requires minimal maintenance. Regular checks can help ensure its longevity and proper function.
- Inspecció de fuites: Periodically check the tap and its connections for any signs of water leaks. Address any leaks immediately.
- Comprovació de funcionament: Occasionally operate the tap (open and close) to ensure the mechanism moves freely and does not seize.
- Neteja: If the exterior becomes dirty, wipe it with a soft, damp tela. No utilitzeu netejadors abrasius ni dissolvents.
- Substitució del segell: If persistent leaks occur from the tap body or spindle, the internal seals (O-rings) may need replacement. This should be performed by a qualified technician.
Resolució de problemes
| Problema | Causa possible | Solució |
|---|---|---|
| Water not flowing into boiler. |
|
|
| Water leaking from tap connections. |
|
|
| Water leaking from tap spindle/body. |
|
|
Especificacions
- Tipus de producte: Boiler Filling Tap with Knob
- Compatibilitat: Hermann, Radiant, Unical, and other compatible boiler systems.
- Fabricant: Genèric
- ASIN: B09V3D9LF5
- Primera data disponible: 2 de maig de 2022

Figure 4: Multiple RURA Boiler Filling Taps shown in their packaging, indicating the product as supplied in bulk or for replacement stock.
Informació de la garantia
For warranty details, please refer to the specific terms and conditions provided by the retailer or manufacturer at the time of purchase. Keep your proof of purchase for any warranty claims.
Atenció al client
If you encounter issues not covered in this manual or require further assistance, please contact your retailer or a qualified heating engineer. Always provide the product model (RURA Boiler Filling Tap) and ASIN (B09V3D9LF5) when seeking support.